8011E

8011E

8011E BST02OLS SYSTEM LOCAL STATUS SEND ERROR OCCURRED - RC: rc

Written to:

SYSLOG, JESMSGLG.

Explanation:

The BSA X-System Router is active. A connection is active or it is being established. Local systems are started while the router is being activated. It is not possible to inform the partner on the status of the local systems because the BSA X-System Router is unable to establish a connection to its partner.

rc

Return code

For TCP/IP error codes, see your IBM manuals. For other errors, see "TCP/IP and VTAM codes".

System Action:

The X-System Router remains active. Current attempts at establishing connections are continued. Some local systems may not be available to the partner.

Operator Response:

Determine the reason for the error, eliminate it, and restart the X-System Router. If the error persists, please contact support.