8009E

8009E

8009E BST02OLS SYSTEM LOCAL STATUS CONNECT ERROR OCCURRED - (tcp_app/RC:rc)

Written to:

SYSLOG, JESMSGLG.

Explanation:

The BSA X-System Router is active, for example, it is establishing a connection to its partner. Local systems are started while the router is being activated. It is not possible to inform the partner on the status of the local systems because the BSA X-System Router is unable to establish a connection to its partner.

tcp_app

Identifies the TCP/IP CONVERSE connection

The name (mm#nnnnn) consists of a two-digit sequential number plus the separator # plus the port number specified in the LST parameter BSA_OCF_ TCPIP_ CONVERSE, for example, 01#65004. The sequential number 00 is used for the base connection according to BSA_OCF_ TCPIP_ PORT.

rc

Return code

For TCP/IP error codes, see your IBM manuals. For other errors, see "TCP/IP and VTAM codes".

System Action:

The X-System Router remains active. Current attempts at establishing connections are continued. Some local systems may not be available to the partner.

Operator Response:

Determine the reason for the error, eliminate it, and restart the X-System Router. If the error persists, please contact support.