8006E

8006E

8006E (function): PIPE ESTABLISHMENT TO tcp_app (RC: error) NOT POSSIBLE

Written to:

SYSLOG, JESMSGLG.

Explanation:

The BSA X-System Router has been started. The B02LSTxx member contains parameters for defining an OCF connection (Converse) via TCP/IP. The connection could not be established.

function

Name of the SFF function which was used for activating the functionality

mm#nnnnn is displayed in case of the send function, where nnnnn is the port number and mm a two-digit sequential number (00 indicates the base connection (BSA_OCF_ TCPIP_ PORT)).

tcp_app

Identifies the TCP/IP CONVERSE connection

The name (mm#nnnnn) consists of a two-digit sequential number plus the separator # plus the port number specified in the LST parameter BSA_OCF_ TCPIP_ CONVERSE, for example, 01#65004. The sequential number 00 is used for the base connection according to BSA_OCF_ TCPIP_ PORT.

error

Error code

For TCP/IP error codes, see your IBM manuals. For other errors, see "TCP/IP and VTAM codes".

System Action:

OCF subsystem initialization is terminated abnormally.

Operator Response:

Determine the reason for the error, eliminate it, and restart the X-System Router. If the error persists, please contact support.