8003I
SYSLOG, JESMSGLG.
The BSA X-System Router has been started. The B02LSTxx member defines an OCF connection via TCP/IP. An error has occurred during activation, for example, the specified TCP/IP task is not active or the specified partner port is not available. Retry attempts to establish a connection will be carried out according to the defined retry interval and retry count.
function
Name of the SFF function which was used for activating the functionality
mm#nnnnn is displayed in case of the send function, where nnnnn is the port number and mm a two-digit sequential number (00 indicates the base connection (BSA_OCF_
port
Number of the port that is to be opened
ipa
IP address where the port is to be opened
time
Retry time interval (in seconds)
count
Retry count
The retry mechanism is activated. The system continues processing. Message 8003W will be output if the application fails to establish a connection after the specified number of retry attempts.
Determine the reason for the error, eliminate it, and restart the X-System Router. If the error persists, please contact support.