Allocating a new dataset for a trace
Allocating a new dataset for a trace
Overview
In the lower part of the "Dynamic Trace Activation/Deactivation" panel you can optionally allocate a file for the trace output. You can choose between an existing dataset, or new dataset, or SYSOUT.
Procedure
To allocate a new dataset for trace output:
- Select option 2.7 to display the "Dynamic Trace Activation/Deactivation" panel.
- In the upper part of the panel, activate a trace by setting a keyword in the NewValue field.
- In the lower part of the panel, specify NEW in the Disposition field and a dataset name in the Data Set Name field, and press ENTER.
An additional panel is displayed, where you can specify the necessary parameters for allocating a new dataset for output of
the trace data.
- In the "Trace Data Set Allocation Parameter" panel, specify the following:
- Space units in blocks, tracks or cylinders
- Primary and secondary quantity in above units
- Volume serial number
- Unit type
- Blocksize (if space units are in blocks)
- Storage class, data class and management class for SMS management
After successful allocation you will receive a message that the dataset will be used for the trace.
Note
- If allocation fails, the trace request will be canceled.
- To allocate a dataset you will need the security rights for the started task and the online user for the relevant dataset.