Displaying LST parameters (Option 1.1)

Option 1.1

Use option 1.1 to display all or specific LST parameters defined in the started task (STC) at the time of its activation.

Notes

  • It is not possible to enter 1.1 directly in the "Service Manager Selection Menu". The "Display/Change Started Task Parameters" menu must be opened as an intermediate step.
  • For detailed information on LST parameter names and allowed values, see the BSA Installation and System Guide and the Beta product documentation.

Procedure

  1. Select option 1 from the "Service Manager Selection Menu". The "Display/Change Started Task Parameters" panel is called:

    PEB4BR00 ----------------------------------------------------------------------
    Option ===> __________________________________________________________________

    Display/Change Started Task Parameters Subsys-ID - B88P
    Sysname - BETA

    1 PARM - Display Keywords/Values
    2 MODIFY - Display Modifiable Keywords/Values
    3 SYSVAR - Check SYSVAR Substitution




    Selection only valid for option 1 (PARM):
    Please enter a keyword ( fully qualified or generic ) below.
    Use blank or asterisk for all keywords.

    Keyword ===> *_______________________________



    Select one of the above options or press ENTER directly to select option 1.
    Press END to return to the previous menu.

  2. You can now generate a list of all LST parameters, or of selected parameters only:
    • To view all LST parameters: Simply select option 1 from the "Display/Change Started Task Parameters" panel without entering anything in the Keyword field.
    • To view selected LST parameters only: First specify a full-qualified keyword or a mask in the Keyword field, then select option 1 from the "Display/Change Started Task Parameters" panel.

Result

Depending on whether you specified a Keyword, all or selected LST parameters are displayed in the "Display Parameter Keywords/Values" table:

PEB4DI01 ------------------------------------------------------ Row 1 of 32
 Command ===> ________________________________________________ Scroll ===> PAGE

 Display Parameter Keywords/Values Subsys-ID - B88P
 Sysname - BETA
 U - Update I - Insert D - Delete Seg.: 1 / 7

 S U L A Keyword Value
 N S Y A2G_SUPPORT YES
 N P Y BQL_MASTER_SSID B88V
 N P Y BQL_SHARE_OPTION ALL
 Y O Y BQL_TRACE YES
 Y P N BQL_TRACE YES
 N O Y B01LST WY
 N P Y B88_COMMENT BETA88P IS NOW RUNNING (PROD SYSTEM)
 N P Y B88_CS_EXITS NO
 N P Y B88_EXIT_CRYPT_TRACE NO
 Y P Y B88_EXIT_TRACE NO
 N P Y B88_LICX_DSNAME BETA88.PROD.LICX
 Y P Y B88_LOG_CHECKS YES
 N P Y B88_SSID B88P
 N P Y B88_TCM_SERVICE YES
 N P Y B88_TCPIP_PORT_RDF 5886,10.56.83.100,TCPIP
 N P Y B88_TCPIP_PORT_WHD 5887,10.56.83.100,TCPIP

Columns

Column

Description

S

Input field for a line command

U

Update flag

L

Location

A

Active flag

When a keyword occurs more than once, the keyword that is found first is normally activated and used.

Keyword

PARM keyword

Value

Value associated with the keyword

Line commands

The following line commands are available in the panel:

U

Update keywords and values

I

Insert keywords and values

D