Operator Commands

Operator commands for the Fastpath manager must be passed through the Adabas System Coordinator daemon with an "AFP" prefix, as shown below. The following commands are available through the MVS Modify (F) command, VSE operator command, and BS2000 commands.

Command Description
AFP RESTART

Perform an orderly shutdown immediately followed by buffer initialization. (See note 2)

AFP NEWCOPY

Perform an orderly shutdown, load a new copy of the Fastpath nucleus for all connected Fastpath components, and initialize the buffer. (See note 2)

Warning:
In multisystem implementations check whether all COR daemons in the group that are expected to be active are active, before issuing an AFP RESTART or NEWCOPY. If direct-access optimization has been automatically disabled due to a system failure or COR daemon failure then this action will override it, which could lead to data integrity problems if the AFP RESTART/NEWCOPY is issued before all necessary daemons are active.

AFP STAT
AFP DSTAT

Display general performance statistics.
AFP SNAP Take a snap dump of the Fastpath buffer. Operation is not terminated.

Notes:

  1. You can achieve all the above actions using Adabas Fastpath Online administration (see SYSAFP Special Services) without needing to enter an operator command.
  2. Multi-task clients (such as RPC and NDV servers) are not compatible with the dynamic Restart or Newcopy. Such jobs should be stopped before issuing the Fastpath operator command and restarted after the action has completed.
Command Description
AFP HELP Display all possible operator commands.