User ZAPs to Change Data Set Options

This document describes items that can be zapped for the Delta Save Facility. The Adabas Installation documentation contains a complete table of values.


VSE/ESA and z/VSE ZAP Table for Delta Save

The "verify/replace" values (VER/REP) shown in the following table permit user-specified device types to be changed ("zapped") for VSE/ESA files.

Utility VSE/ESA, z/VSE File* Default
SYS Number
PTT
Offset*
VER REP
ADASAV FULL SYS030 2D8 1A1E 1Axx
DEL1 SYS031 2E8 1A1F 1Axx
DEL2 SYS032 2F8 1A20 1Axx
DEL3 SYS033 308 1A21 1Axx
DEL4 SYS034 318 1A22 1Axx
DEL5 SYS035 328 1A23 1Axx
DEL6 SYS036 338 1A24 1Axx
DEL7 SYS037 348 1A25 1Axx
DEL8 SYS038 358 1A26 1Axx

BS2000/OSD ZAP Table for Delta Save

The tape rewind defaults in the following table can be changed to

0000: rewind
1000: no rewind
2000: rewind/unload

All offset values are hexadecimal:

Utility BS2000 File* PTT Offset* Default
ADASAV FULL 2DC 2000
DEL1 2EC 2000
DEL2 2FC 2000
DEL3 30C 2000
DEL4 31C 2000
DEL5 32C 2000
DEL6 33C 2000
DEL7 34C 2000
DEL8 35C 2000

* The PTT base address is CSECT I_PTT in module ADAIOR. Add the PTT offset value to this base address to obtain the complete address.