Adabas Commands

Each Adabas command is described in the table below; select a command to see detailed control block and buffer information for it. In addition, the following summary tables are provided showing the use of the ACB, ACBX, and buffers by all Adabas commands:

Note:
We recommend that you set unused ACB and ACBX fields to binary zeros before a direct call is initiated.

Command Code Summary Description
A1 Update record Update record(s) (hold option)
BT Backout transaction Remove database updates for ET logic users
C1 Write checkpoint Write command ID, PLOG, RABN RABN checkpoint, buffer flush option
C3 Write SYNX-03 checkpoint Write SYNX-03 checkpoint for exclusive control update users; option to store user data
C5 Write user data to protection log Write user data on SIBA/PLOG
CL Close user session End ET session and update database
E1 Delete record / refresh file Delete record (hold option) or refresh file
ET End transaction End and save current transaction
HI Hold record Prevent record update by other users
L1 Read record Read record of specified ISN
L2 Read physical sequential record Read records in physical order
L3 Read logical sequential record Read records in descriptor value order
L4 Read and hold record Read record and hold, "wait for held record/issue return code" option
L5 Read physical sequential record and hold Read records in physical order and hold, "wait/issue return code" option
L6 Read logical sequential record and hold Read records in descriptor value order with "wait/issue return code" option
L9 Read descriptor values Read the values of a specified descriptor
LF Read field definition Read the characteristics of all fields in a file
N1 Add record with Adabas-assigned ISN Add new database record with ISN assigned by Adabas
N2 Add record with user-assigned ISN Add new database record with user-assigned ISN
OP Open user session Open user session
RC Release command ID or global format ID Release one or more command IDs or a global format ID for the issuing user
RE Read ET user data Read ET data for this, another, or all users
RI Release held record and ISN Release held record and ISN
S1 Find records Return count and ISNs of records satisfying the search criterion
S2 Find records in user-specified order Return count of records and ISNs in user-specified order
S4 Find records and hold Return count and ISNs of records satisfying the search criterion and put first ISN in list on hold
S5 Find coupled ISNs Return or save a list of coupled ISNs for the specified file
S8 Process ISN lists Combine two ISN lists from the same file with an AND, OR, or NOT operation
S9 Sort ISN lists Sort ISN list in ascending ISN or descriptor-specified sequence

Adabas includes some V* and Y* commands, which you may see mentioned in Adabas shutdown statistics or in Adabas Online System (AOS) screens. These commands are used internally by Adabas and Adabas add-on products and should not be used in direct calls in your applications. Should you use them, errors will result.


Adabas Command ACBs

graphics/cmdacb.png

graphics/cmdacb.png

ACB Command Buffers

graphics/bufacb.png

Adabas Command ACBXs

graphics/cmdacbx.png

ACBX Command ABDs and Buffers

graphics/bufacbx.png

A1 Command -- Update Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric / binary F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F U
ISN Lower Limit 17-20 binary -- A1
ISN Quantity 21-24 binary -- A1
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
  29-34 -- -- --
Command Option 1 / 2 35-36 alphanumeric F U
  37-44 -- -- --
Additions 2 45-48 alphanumeric / binary   A
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Notes

  1. These fields are used and not reset by Adabas if coupled files are used.

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F U
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 binary --- ---
Version Indicator 3-4 binary F U
  5-6 binary --- ---
Command Code 7-8 alphanumeric F U
  9-10 binary --- ---
Response Code 11-12 binary --- U
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F U
  33-36 --- --- ---
ISN Lower Limit 37-40 binary --- A1
  41-44 --- --- ---
ISN Quantity 45-48 binary --- A1
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
  169-193 --- --- ---

Notes

  1. These fields are used and not reset by Adabas if coupled files are used.

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F U
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used

BT Command -- Back Out Transaction

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 binary -- A
File Number * 9-10 binary F * U
Response Code 11-12 binary -- A
  13-16 -- -- --
ISN Lower Limit 17-20 binary F U
  21-32 -- -- --
ISN Buffer Length ** 33-34 binary F ** U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
  37-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
ISN ** F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if Command Option 2 is specified
** Required only if Command Option 1 is specified
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 binary --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary --- A
Database ID* 17-20 numeric F* U
File Number* 21-24 numeric F* U
  25-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  45-48 --- --- ---
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
Command Option 3 51 alphanumeric F U
  52-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
  169-193 --- --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
ISN ** F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if Command Option 2 is specified
** Required only if Command Option 1 is specified
--- Not used

C1 Command -- Record Checkpoint

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F A
File Number * 9-10 binary F U
Response Code 11-12 binary -- A
  13-34 -- -- --
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
  37-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F A
Database ID* 17-20 numeric F U
  21-48 --- --- ---
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
  169-193 --- --- ---

ABDs and Buffers

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
--- Not used

C3 Command -- Write Checkpoint

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
  5-8 -- -- --
File Number ** 9-10 binary F U
Response Code 11-12 binary -- A
  13-26 -- -- --
Record Buffer Length 27-28 binary F U
  29-35 -- -- --
Command Option 2 36 alphanumeric F U
  37-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format *  
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of call statement
** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
--- 13-16 --- --- ---
Database ID** 17-20 numeric F U
  21-49 --- --- ---
Command Option 2 50 alphanumeric F U
  51-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
  169-193 --- --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format *  
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but should be included in Adabas call or one will be automatically generated.
** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

C5 Command -- Write User Data to PLOG

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
  5-8 -- -- --
File Number ** 9-10 binary F U
Response Code 11-12 binary -- A
  13-26 -- -- --
Record Buffer Length 27-28 binary F U
  29-34 -- -- --
Command Option 1*** 35 alphanumeric F U
  36 -- -- --
Additions 1*** 37-44 alphanumeric F U
  45-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format *  
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of call statement
** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).

However, if you are using Event Replicator for Adabas and the Command Option 1 field is set to "R", a file number must be specified to identify the file to which the C5 command applies. For more information, read your Event Replicator for Adabas documentation.

*** Only used if you are using Event Replicator for Adabas. For more information, read your Event Replicator for Adabas documentation.
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
  13-16 --- --- ---
Database ID** 17-20 numeric F U
File Number*** 21-24 numeric F U
  25-48 --- --- ---
Command Option 1*** 49 alphanumeric F U
  50-56 --- --- ---
Additions 1*** 57-64 alphanumeric/ binary F U
  65-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format *  
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but should be included in Adabas call or one will be automatically generated.
** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).

However, if you are using Event Replicator for Adabas and the Command Option 1 field is set to "R", a file number must be specified to identify the file to which the C5 command applies. For more information, read your Event Replicator for Adabas documentation.

*** Only used if you are using Event Replicator for Adabas. For more information, read your Event Replicator for Adabas documentation.
--- Not used

CL Command -- Close Session

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 binary -- A
File Number *** 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary -- A
ISN Lower Limit 17-20 binary -- A
ISN Quantity 21-24 binary -- A
  25-26 -- -- --
Record Buffer Length 27-28 binary F * U
  29-35 -- -- --
Command Option 2 36 alphanumeric F U
  37-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format * ** --
Record * F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if user data is to be stored
** Not used but must be included in parameter list of call statement if user data to be stored
*** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary --- A
Database ID*** 17-20 numeric F U
  21-28 --- --- ---
Number of I/Os 29-32 binary --- A
  33-36 --- --- ---
Number of Commands 37-40 binary --- A
CPU Time 41-48 binary --- A
  49 --- --- ---
Command Option 2 50 alphanumeric F U
  51-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format * ** --
Record * F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if user data to be stored
** Not used but should be included in Adabas call or one will be automatically generated.
*** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

E1 Command -- Delete Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric / binary F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F U
ISN Lower Limit 17-20 binary -- A1
ISN Quantity 21-24 binary -- A1
  25-34 -- -- --
Command Option 1 35 alphanumeric F U
  36-48 -- -- --
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
  65-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Notes

  1. These fields are used and not reset by Adabas if coupled files are used.

Buffer Areas

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28   --- ---
ISN 29-32 binary F U
  33-36   --- ---
ISN Lower Limit 37-40 binary --- A1
  41-44   --- ---
ISN Quantity 45-48 binary --- A1
Command Option 1 49 alphanumeric F U
  50-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
  85-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

Notes

  1. These fields are used and not reset by Adabas if coupled files are used.

ABDs and Buffers

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used

ET Command -- End Transaction

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 binary -- A
File Number**** 9-10 binary F U
Response Code 11-12 binary -- A
  13-16 -- -- --
ISN Lower Limit 17-20 binary F U
ISN Quantity 21-24 binary -- A
  25-26 -- --  
Record Buffer Length 27-28 binary F * U
  29-32 -- -- --
ISN Buffer Length ** 33-34 binary F ** U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
  37-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format * *** --
Record * F U
ISN ** F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if ET data is to be stored
** Required for hold ISN option; optional for multifetch option
*** Not used but must be included in parameter list of call statement if ET data is to be stored
**** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary --- A
Database ID**** 17-20 numeric F U
  21-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-44 --- --- ---
ISN Quantity 45-48 binary --- A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
Command Option 3 51 alphanumeric F U
  52-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format * *** --
Record * F U
ISN ** F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only of ET data to be stored
** Required for hold ISN option; optional for multifetch option
*** Not used but should be included in Adabas call if ET data is to be stored. If not specified, one will be automatically generated.
**** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
--- Not used

HI Command -- Hold Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
  5-8 -- -- --
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F U
  17-34 -- -- --
Command Option 1 35 alphanumeric F U
  36-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
--- 13-16 --- --- ---
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F U
  33-48 --- --- ---
Command Option 1 49 alphanumeric F U
  50 --- --- ---
Command Option 3 51 alphanumeric F U
  52-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

Buffer Areas

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

L1/L4 Commands -- Read Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F U *
ISN Lower Limit 17-20 binary F U
  21-24 -- -- --
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
  29-32 -- -- --
ISN Buffer Length ** 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
  37-44 -- -- --
Additions 2 45-48 binary / binary -- A
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F U
Record -- A
ISN ** -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Except for special options
** The ISN buffer and length are required only if the multifetch or prefetch option is specified
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F U*
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-48 --- --- ---
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
Command Option 3 (L4 only) 51 alphanumeric F U
  52-64 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F U
Record -- A
Multifetch ** -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Except for special options
** The multifetch buffer is required only if the multifetch option is specified.
--- Not used

L2/L5 Commands -- Read Physical Sequential Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F A
ISN Lower Limit 17-20 binary F U
  21-24 -- -- --
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
  29-32 -- -- --
ISN Buffer Length * 33-34 binary F U
Command Option 1 35 alphanumeric F U
  36-44 -- -- --
Additions 2 45-48 binary / binary -- A
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F** U
Record -- A
ISN * F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* The ISN buffer and length are required only of the multifetch or prefetch option is specified
** May contain compress option control characters "C."
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-48 --- --- ---
Command Option 1 49 alphanumeric F U
  50 --- --- ---
Command Option 3 (L5 only) 51 alphanumeric F U
  52-64 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F** U
Record -- A
Multifetch * F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* A multifetch buffer is required only if the multifetch option is specified.
** May contain compress option control characters "C."
--- Not used

L3/L6 Commands -- Read Logical Sequential Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 binary -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F A
ISN Lower Limit 17-20 binary F U
  21-24 -- -- --
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
Search Buffer Length 29-30 binary F * U
Value Buffer Length 31-32 binary F * U
ISN Buffer Length ** 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F A
Additions 2 45-48 binary / binary -- A
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F *** U
Record -- A
Search * F U
Value * F U
ISN ** F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if value start option is being used
** The ISN buffer and length is required only if the multifetch or prefetch option is specified.
*** May contain compress option control characters "C."
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-48 --- --- ---
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
Command Option 3 (L6 only) 51 alphanumeric F U
  52-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F A
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F *** U
Record -- A
Search * F U
Value * F U
Multifetch ** F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Required only if value start option is being used
** The multifetch buffer is required only if the multifetch option is specified.
*** May contain compress option control characters "C."
--- Not used

L9 Command -- Read Descriptor Values

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary -- A
ISN Lower Limit 17-20 binary F A
ISN Quantity 21-24 binary -- A
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
Search Buffer Length 29-30 binary F U
Value Buffer Length 31-32 binary F U
ISN Buffer Length * 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
Additions 2 45-48 binary -- A
Additions 3 49-56 alphanumeric F A
  57-64 -- -- --
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F U
Record -- A
Search F U
Value F U
ISN * -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* The ISN buffer and length required only if the multifetch or prefetch option is specified
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary --- A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F A
  41-44 --- --- ---
ISN Quantity 45-48 binary --- A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
--- 65-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
  77-84 --- --- ---
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F U
Record --- A
Search F U
Value F U
Multifetch * --- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* The multifetch buffer is required only if the multifetch option is specified
--- Not used

LF Command -- Read Field Definitions

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
  5-8 -- -- --
File Number 9-10 binary F U
Response Code 11-12 binary -- A
  13-26 -- -- --
Record Buffer Length 27-28 binary F U
  29-35 -- -- --
Command Option 2 36 alphanumeric F U
  37-48 -- -- --
Additions 3 49-56 alphanumeric F A
  57-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format * --
Record -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of call statement
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
  13-16 --- --- ---
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-49 --- --- ---
Command Option 2 50 alphanumeric F U
  51-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
  77-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format * --
Record -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but should be included in Adabas call or one will be automatically generated.
-- Not used

N1/N2 Commands -- Add New Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F A/U1
ISN Lower Limit 17-20 binary -- A2
ISN Quantity 21-24 binary -- A2
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
  29-44 -- -- --
Additions 2 45-48 alphanumeric -- A
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Notes

  1. Supplied by Adabas for N1; unchanged for N2.

  2. These fields are used and not reset by Adabas if coupled files are used.

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F U
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F A/U1
  33-36 --- --- ---
ISN Lower Limit 37-40 binary --- A2
  41-44 --- --- ---
ISN Quantity 45-48 binary --- A2
  49-64 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

Notes

  1. Supplied by Adabas for N1; unchanged for N2.

  2. These fields are used and not reset by Adabas if coupled files are used.

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F U
Record F U

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used

OP Command -- Open User Session

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric -- A
File Number** 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary -- A
ISN Lower Limit 17-20 binary F A
ISN Quantity 21-24 binary F A
  25-26 -- -- --
Record Buffer Length 27-28 binary F U
  29-34 -- -- --
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
Additions 2 45-48 alphanumeric -- A
  49-56 -- -- --
Additions 4 57-64 binary F A
Additions 5 65-72 binary -- A
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format *  
Record F A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of the call statement
** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary --- A
Database ID** 17-20 numeric F U
  21-28 --- --- ---
ISN 29-32 binary --- A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F A
  41-44 --- --- ---
ISN Quantity 45-48 binary F A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
Additions 2 65-68 binary --- A
  69-76 --- --- ---
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary --- A
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format *  
Record F A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but should be included in Adabas call or one will be automatically generated.
** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

RC Command -- Release Command ID or Global Format ID

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
  13-34 -- -- --
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
  45-64 -- -- --
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-48 --- --- ---
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
  65-84   --- ---
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

RE Command -- Read ET User Data

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 binary -- A
File Number **** 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F A
  17-26 -- -- --
Record Buffer Length 27-28 binary F U
  29-34 -- -- --
Command Option 1 35 alphanumeric F U
  36 -- -- --
Additions 1 37-44 alphanumeric F * U/A **
Additions 2 45-48 alphanumeric -- A
  49-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format *** --
Record -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Supplied ET data user ID when Command Option 1 equals "I"
** User ID for ET data in record buffer if Command Option 1 equals "A"
*** Not used but must be included in parameter list of call statement
**** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary --- A
Database ID**** 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F A
  33-48 --- --- ---
Command Option 1 49 alphanumeric F U
  50-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F* U/A**
Additions 2 65-68 binary --- A
  69-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format *** --
Record -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Supplied ET data user ID when Command Option 1 equals "I"
** User ID for ET data in record buffer if Command Option 1 equals "A"
*** Not used but should be included in Adabas call or one will be automatically generated.
**** A database ID is only necessary if you are accessing a database other than the application's default database (read in by ADARUN DBID parameter, provided in the loaded link globals table, or linked with the link routine).
--- Not used

RI Command -- Release Held Record

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
  5-8 -- -- --
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F U
  17-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
  13-16 --- --- ---
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F U
  33-50 --- --- ---
Command Option 3 51 alphanumeric F U
  52-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

None used.

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used

S1/S2/S4 Commands -- Find Records

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary -- A
ISN Lower Limit 17-20 binary F U
ISN Quantity 21-24 binary F * A
Format Buffer Length 25-26 binary F U
Record Buffer Length 27-28 binary F U
Search Buffer Length 29-30 binary F U
Value Buffer Length 31-32 binary F U
ISN Buffer Length 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
Additions 2 45-48 binary / binary -- A
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
Additions 5 65-72 alphanumeric F U
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format F U
Record -- A
Search F U
Value F U
ISN -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Optional timeout value, in seconds
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary --- A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-44 --- --- ---
ISN Quantity 45-48 binary F* A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
Command Option 3 (S4 only) 51 alphanumeric F U
  52-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
Additions 5 85-92 alphanumeric/ binary F U
  93-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-128 --- --- ---
Compressed Record Length 129-136 binary --- A
Decompressed Record Length 137-144 binary --- A
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
Format F U
Record --- A
Search F U
Value F U
ISN --- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Optional timeout value, in seconds
--- Not used

S5 Command -- Find Coupled ISNs

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary F A
ISN Lower Limit 17-20 binary F U
ISN Quantity 21-24 binary -- A
  25-32 -- -- --
ISN Buffer Length 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
  45-48 -- -- --
Additions 3 49-56 alphanumeric F A
  57-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format * --
Record * --
Search * --
Value * --
ISN -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of call statement
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary F A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-44 --- --- ---
ISN Quantity 45-48 binary --- A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
  65-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
  77-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
ISN --- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used

S8 Command -- Process ISN Lists

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary -- A
ISN Lower Limit 17-20 binary F U
ISN Quantity 21-24 binary -- A
  25-32 -- -- --
ISN Buffer Length 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
  45-48 -- -- --
Additions 3 49-56 alphanumeric F A
  57-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format * --
Record * --
Search * --
Value * --
ISN -- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of call statement

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary --- A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-44 --- --- ---
ISN Quantity 45-48 binary --- A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
  65-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
  77-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
ISN --- A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used

S9 Command -- Sort ISN List

We recommend that you set unused ACB and ACBX fields to binary zeros before the direct call is initiated.

ACB Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 -- -- --
Command Code 3-4 alphanumeric F U
Command ID 5-8 alphanumeric F U
File Number 9-10 binary F U
Response Code 11-12 binary -- A
ISN 13-16 binary -- A
ISN Lower Limit 17-20 binary F U
ISN Quantity 21-24 binary F A
  25-32 -- -- --
ISN Buffer Length 33-34 binary F U
Command Option 1 35 alphanumeric F U
Command Option 2 36 alphanumeric F U
Additions 1 37-44 alphanumeric F U
  45-48 -- -- --
Additions 3 49-56 alphanumeric F A
Additions 4 57-64 alphanumeric F A
  65-72 -- -- --
Command Time 73-76 binary -- A
User Area 77-80 -- -- U

Buffer Areas

Buffer Before Adabas Call After Adabas Call
Format * --
Record * --
Search * --
Value * --
ISN F A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
* Not used but must be included in parameter list of call statement
-- Not used

ACBX Control Block Structure

Field Position Format Before Adabas Call After Adabas Call
  1-2 --- --- ---
Version Indicator 3-4 binary F U
  5-6 --- --- ---
Command Code 7-8 alphanumeric F U
  9-10 --- --- ---
Response Code 11-12 binary --- A
Command ID 13-16 alphanumeric/ binary F U
Database ID 17-20 numeric F U
File Number 21-24 numeric F U
  25-28 --- --- ---
ISN 29-32 binary --- A
  33-36 --- --- ---
ISN Lower Limit 37-40 binary F U
  41-44 --- --- ---
ISN Quantity 45-48 binary F A
Command Option 1 49 alphanumeric F U
Command Option 2 50 alphanumeric F U
  51-56 --- --- ---
Additions 1 57-64 alphanumeric/ binary F U
  65-68 --- --- ---
Additions 3 69-76 alphanumeric/ binary F A
Additions 4 77-84 alphanumeric F A
  85-114 --- --- ---
Error Subcode 115-116 binary --- A
  117-144 --- --- ---
Command Time 145-152 binary --- A
User Area 153-168 not applicable --- U
--- 169-193 do not touch --- ---

ABDs and Buffers

ABD and Buffer Before Adabas Call After Adabas Call
ISN F A

where:

F Supplied by user before Adabas call
A Supplied by Adabas
U Unchanged after Adabas call
--- Not used