POPnnn messages are issued from the Adabas System Coordinator Adabas server component.
POP000I | POP001S | POP002S | POP003E | POP004E | POP005E | POP006S | POP008E
POP000I | ADAPOP V##### INITIALISED, EP=######## CIB=######## |
Explanation |
The database interface to the Adabas System Coordinator has been initialized successfully. |
Action |
None. This message is for information only. |
POP001S | ADAPOP CANNOT INITIALIZE, GETMAIN ERROR |
Explanation |
ADAPOP cannot initialize because of a memory shortage. |
Action |
Increase the region specification for the database job. |
POP002S | ADAPOP CANNOT INITIALIZE, KERNEL LOAD ERROR |
Explanation |
ADAPOP failed to locate or load the runtime kernel module CORKRN. |
Action |
Ensure that the load library containing the kernel module is available to the database job. |
POP003E | Database proxy module ######## for product ### is invalid (bad eyecatcher) |
Explanation |
The database component for the indicated product is invalid. |
Action |
Check and correct the installation. |
POP004E | Database proxy module ######## for product ### is not supported |
Explanation |
The database component for the indicated product is not supported by this version of the Adabas System Coordinator Adabas server component. |
Action |
The affected product is disabled for this Adabas nucleus. Ensure that you use the correct product versions. |
POP005E | Memory shortage alert-no memory for COR threads, add-ons are deactivated |
Explanation |
An Adabas option command cannot be completed because of a memory shortage. |
Action |
The affected commands will receive RSP101/24. There is a possibility that some critical command-related processing was
not able to be performed in the case where this message appears. The most
critical situation is where Adabas Fastpath is in full operation for the
database (beyond a simple AFPLOOK sample). In this case Fastpath will attempt
to automatically switch off optimization for the database to ensure there is no
risk to the coherence between cache and database content. The administrator
should check to make sure this has happened and if there is any doubt, manually
stop the optimization for the database - or shut the entire Fastpath caching
down. More memory needs to be made available to the System Coordinator within
the database job. This may be achieved by making more memory available to the
job (increasing REGION size etc.) or if there is no more memory available for
the job then reduceing |
POP006S | APPEND OF PRODUCT V-CON LIST FAILED |
Explanation |
This is an internal error. |
Action |
Contact your Software AG technical support representative. |
POP008E | IOR FAILURE - FUNCTION: ## ERROR ## |
Explanation |
An internal error occurred during the processing of an operating system dependent function. |
Action |
Contact your Software AG technical support representative for assistance. |