The INCREASE function increases the size of the last data set currently being used for the Associator or Data Storage. This function may be executed any number of times for the Associator. The maximum of 99 Data Storage Space Tables (DSSTs) somewhat limits Data Storage increases before all 99 Data Storage extents must be combined into a single extent with either the REORASSO or REORDB function of the ADAORD utility.
Notes:
This document covers the following topics:
The additional number of blocks or cylinders needed by the Associator or Data Storage data set. To specify blocks, add a "B" after the value; for example, DATASIZE=50B.
When a parameter error or a functional error occurs while this utility function is running, the utility ordinarily prints an error message and terminates with user abend 34 (with a dump) or user abend 35 (without a dump). If NOUSERABEND is specified, the utility will not abend after printing the error message. Instead, the message "utility TERMINATED DUE TO ERROR CONDITION" is displayed and the utility terminates with condition code 20.
Note:
When NOUSERABEND is specified, we recommend that it be specified
as the first parameter of the utility function (before all other parameters).
This is necessary to ensure that its parameter error processing occurs
properly.
Use the TEST parameter to test the operation syntax without actually performing the operation. Only the syntax of the specified parameters can be tested; not the validity of values and variables. See Syntax Checking with the TEST Parameter for more information about using this parameter.
The Associator is to be increased by 400 cylinders.
ADADBS INCREASE ASSOSIZE=400
Note:
On BS2000 systems, we strongly recommend using blocks because
cylinders do not exist on this platform. PAM page sizes can be more easily
calculated from blocks or RABNs (for more information, read
Device and File
Considerations. So this might be, say:
ADADBS INCREASE ASSOSIZE=60000B
The general procedure for increasing the size of the Associator or Data Storage is as follows:
Back up the database using the ADASAV utility. This step is optional but recommended.
Execute the ADADBS INCREASE function.
Format the additional space being added to the data set with the ADAFRM utility.
Under z/OS, the same data set may be formatted by specifying the DISP=MOD parameter in the JCL. The SPACE parameter for the data set being increased should be set to
SPACE=(CYL,(0,n))
where n is the amount of space (in cylinders) being added. The ADAFRM control statement should also specify the number of cylinders being added. If the increased part of the data set to be formatted is contained on a new volume, the VOL parameter of the JCL must include references to all volumes containing the data set.
400 cylinders are to be added to an Associator data set which currently contains 300 cylinders. The control statement for the INCREASE function would be:
ADADBS INCREASE ASSOSIZE=400
The following JCL example increases the Associator data set using ADAFRM:
//DDASSOR1 DD DSN=....,DISP=MOD,SPACE=(CYL,(0,400))
and the actual ADAFRM control statement would be
ADAFRM ASSOFRM SIZE=400
To provide the increase in example 1 for multiple volumes, specify the volumes in the JCS:
//DDASSOR1 DD DSN=... // DISP=(MOD,CATLG),VOL=SER=(V1,V2,...),SPACE=(CYL,(0,400))...
Include the following step after the INCREASE step but before the FORMAT step to ensure a correct catalog entry:
//UNCATLG EXEC PGM=IEFBR14 //DDASSOR1 DD DSN=...,DISP=(SHR,UNCATLG)
The following procedures are recommended for increasing Associator or Data storage:
Save the current database.
End the Adabas session normally with the ADAEND operator command.
Update the JCS defining the database to add the new extent on the same volume.
Before a new Associator or Data extent on either a different or the same z/VSE volume can be increased with ADADBS INCREASE and formatted with ADAFRM, that volume's table of contents (VTOC) must be updated to contain the new extent.
Use a job similar to the following example to update the VTOC for a single volume extent:
* $$ JOB JNM=jobname * $$ LST ... * $$ PCH ... // ASSGN SYS001,DISK,VOL=volume,SHR // DLBL ASSOEXT,'dsname',99/365,DA // EXTENT SYS001,volume1,1,0,starttrack1,trackcount1 // EXTENT SYS001,volume1,1,1,starttrack2,trackcount2 // EXEC ASSEMBLY,GO MODVTOC CSECT BALR 9,0 BCTR 9,0 BCTR 9,0 USING MODVTOC,9 OPEN ASSOEXT CLOSE ASSOEXT EOJ RC=0 ASSOEXT DTFPH TYPEFLE=OUTPUT,DEVADDR=SYS001,DEVICE=DISK,MOUNTED=ALL END /* /& * $$ EOJ
For a two-volume extent, use a job similar to the following example:
* $$ JOB JNM=jobname * $$ LST ... * $$ PCH ... // ASSGN SYS001,DISK,VOL=volume1,SHR // ASSGN SYS002,DISK,VOL=volume2,SHR // DLBL ASSOEXT,'dsname',99/365,DA // EXTENT SYS001,volume1,1,0,starttrack1,trackcount1 // EXTENT SYS002,volume2,1,1,starttrack2,trackcount2 // EXEC ASSEMBLY,GO MODVTOC CSECT BALR 9,0 BCTR 9,0 BCTR 9,0 USING MODVTOC,9 OPEN ASSOEXT CLOSE ASSOEXT EOJ RC=0 ASSOEXT DTFPH TYPEFLE=OUTPUT,DEVADDR=SYS001,DEVICE=DISK,MOUNTED=ALL END /* /& * $$ EOJ
Note:
This job causes z/VSE error message 4733D to be sent to the
console, and the operator is asked for a response. After the JCS has been
validated, the operator response should be DELETE.
Perform the ADADBS INCREASE operation.
Run the new ADAFRM job to format the new extent. The ADAFRM job must specify the FROMRABN parameter, as shown in the following example:
ADAFRM ASSOFRM SIZE=size,FROMRABN=rabn-number
where size is the number of cylinders or blocks by which the data set is to be increased, and rabn-number is the first RABN in the new extent.
Start the Adabas nucleus.
Use the following procedure to increase the database on BS2000 systems:
Execute ADADBS INCREASE as described in section General Procedure.
End the Adabas session with ADAEND.
Produce a database report by running the ADAREP utility. Use the report to find the first RABN for the new extent in the "Physical Layout of the Database" portion of the report. The RABN range is indicated in the "VOLSER NUMBER" column.
Calculate the PAM page space using the information in the Device and File Considerations section for the container type as follows:
Number-PAM-pages-to-increase = (Number-RABNs-to-increase) * (RABN-STD-block-size-for-this-device)
For example, suppose the ADADBS parameter was ADADBS INCREASE ASSOSIZE=60000B. Increasing a 2300 ASSO device by 60000 RABNs needs 120000 PAM pages:
/MODIFY-FILE-ATTRIBUTE ADA99.ASSO,SUP=PUB(SPACE=RELATIVE(120000))
Note:
In the old ISP format, this was performed by the FILE command.
For example, /FILE ADA99.ASSO, SPACE=120000
.
Or, to add onto another volume called "VOL.03":
/MODIFY-FILE-ATTRIBUTE ADA99.ASSO,SUP=PUB(SPACE=RELATIVE(120000),VOLUME=VOL.03)
These commands are made in TSOS for public volumes. The space increase should not set a track unit across two volumes. For more information, read Splitting Data Sets Across Volumes under BS2000 Device Types and Block Sizes.
Format the new space by running the ADAFRM utility. An example for the space added in step 4 is:
ADAFRM ASSOFRM SIZE=400B,FROMRABN=rabn-number
where rabn-number specifies the first RABN shown on the new extent, as shown in the report.
You are entirely responsible for the container expansion above. We therefore strongly recommend that you check carefully that you use the following command to determine whether the highest PAM page calculated from the highest RABN from the ADAREP utility with the highest PAM page is in the container:
/SHOW-FILE-ATTRIBUTES container-name,ALL
The highest PAM page is in the output field HIGH-US-PA.
If the highest PAM page is less than the highest PAM pages from the the ADAREP, accessing the highest RABNs will result in a DMS0922 I/O error.