ART0102I | ART0103E | ART0104I | ART0105I | ART0106I | ART0107I | ART0108E | ART0109E | ART0110E | ART0111E | ART0112I | ART0113I | ART0114I | ART0115E | ART0116I | ART0117I | ART0118I | ART0119E | ART0120E | ART0121E | ART0122I | ART0123E | ART0124I | ART0125I | ART0303I | ART0304I | ART0305I | ART0307I | ART0308I | ART0309I | ART0310I | ART0311I | ART0314I | ART0315I | ART0316I | ART0317I | ART0318I | ART0319I | ART0320E | ART0321E | ART0322E | ART0323I | ART0324E | ART0325I | ART0401I | ART0402I | ART0403I | ART0404I | ART0405I | ART0406I | ART0407I | ART0408I | ART0409I | ART0410I | ART0501I | ART0502I | ART0503I | ART0504I | ART0505I | ART0506I | ART0507E | ART0508E | ART0509E | ART0510E | ART0511E | ART0512E | ART0513E | ART0514E | ART0515I | ART0516I | ART0517E | ART0518E | ART0519E | ART0520E | ART0521E | ART0601I | ART0602E | ART0603I | ART0604E | ART0605E | ART0606E | ART0607E | ART0608E | ART0609E | ART0610E | ART0611E | ART0612E | ART0613I | ART0614I | ART0615E | ART0616E | ART0617E | ART0701I | ART0702I | ART0703I | ART0704I | ART0705E | ART0706E | ART0707E | ART0708E | ART0801I | ART0802I | ART0803I | ART0901E | ART0902I | ART0903I | ART1001E | ART1002E | ART1005W | ART1101I | ART1102I | ART1103E | ART1104I | ART1105I | ART1106I | ART1107I | ART1108E | ART1109I | ART1201I | ART1203W | ART1204E | ART1205E | ART1206E | ART1207E | ART1208I | ART1209I | ART1210I | ART1211E | ART1212E | ART1213E | ART1214W | ART1215E | ART1216E | ART1217F | ART1218F | ART1219E | ART1220E | ART1221E | ART1222E | ART1223E | ART1224E | ART1225E | ART1226E | ART1227E | ART1228E | ART1229E | ART1230E | ART1232E | ART1233I | ART1234I | ART1235W | ART1236E | ART1237W | ART1238I | ART1239I | ART1240E | ART1241W | ART1242E | ART1302I | ART1303E | ART1304E | ART1305E | ART1307E | ART1308E | ART1309E | ART1310I | ART1311I | ART1312I | ART1313I | ART1315I | ART1316E | ART1318I | ART1319E | ART1320E | ART1321E | ART1322E | ART1323E | ART1324E | ART1325E | ART1326I | ART1327E | ART1328E | ART1329E | ART1330E | ART1331E | ART1332E | ART1333E | ART1334E | ART1335E | ART1336E | ART1337E | ART1338E | ART1339W | ART1340E | ART1341E | ART1342E | ART1343W | ART1344W | ART1401I | ART1402E | ART1501I | ART1502I | ART1503I | ART1504I | ART1601I | ART1602I | ART1603I | ART1604I | ART1701W | ART1702W | ART1703W | ART1801E | ART1802E | ART1803E | ART1804I | ART1805I | ART1806E | ART1807E | ART1808E | ART1809E | ART1810E | ART2001E | ART2002E | ART2003E | ART2004E | ART3001E | ART3002E | ART3003E | ART3004E | ART3005E | ART3006E
ART0102I | An Event Replicator Target Adapter engine is started and waiting for work |
Explanation |
An Event Replicator Target Adapter has successfully started and is waiting for work. |
Action |
No action is required for this informational message. |
ART0103E | Unable to load resource bundle; message |
Explanation |
This is an internal error. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0104I | Version information version |
Explanation |
The version of the Event Replicator Target Adapter that is running is given in the message (version). |
Action |
No action is required for this informational message. |
ART0105I | Engine shutdown requested |
Explanation |
A request has been made to shut down the Event Replicator Target Adapter. |
Action |
No action is required for this informational message. |
ART0106I | Main processing loop shutdown requested |
Explanation |
A request has been made to shut down the main processing loop of the Event Replicator Target Adapter. |
Action |
No action is required for this informational message. |
ART0107I | Operation message: input-msg |
Explanation |
An operation message (input-msg) is listed in the text of this message. |
Action |
No action is required for this informational message. |
ART0108E | Invalid or unprocessed message received: msg |
Explanation |
An invalid or unprocessed message was received. The invalid message (msg) is provided in the text of this message. |
Action |
Review any previous messages to determine the primary cause of the problem. If the problem persists, contact your Software AG technical support representative for assistance. |
ART0109E | Cannot connect to target |
Explanation |
An attempt to connect to a defined target failed. |
Action |
Evaluate the target definition to determine the cause of the problem. If you cannot determine the cause of the problem, contact your Software AG technical support representative for assistance. |
ART0110E | Operation status: status |
Explanation |
The status of the failed operation (status) is provided in the text of this message. This message accompanies other error messages. Possible statuses are "Failed" and "FailedRetry". |
Action |
Review the other messages that accompany this one to determine the cause of the problem. If you cannot determine the cause of the problem, contact your Software AG technical support representative for assistance. |
ART0111E | Incorrect message: msg |
Explanation |
The message in error (msg) is provided in the text of this message, which accompanies other error messages. |
Action |
Review the other messages that accompany this one to determine the cause of the problem. If you cannot determine the cause of the problem, contact your Software AG technical support representative for assistance. |
ART0112I | Database retry count is 0 |
Explanation |
The database retry count setting has reached the value of zero (0). No further database retries are attempted and the source is closed. |
Action |
Restart the database and reopen the source. |
ART0113I | Waiting secs seconds before database retry number of total |
Explanation |
The Event Replicator Target Adapter is waiting the number of seconds listed in the message (secs) before attempting to reconnect to the source database. The retry attempt number (number) and the total number of retry attempts defined for the source (total) are also given in the message. |
Action |
No action is required for this informational message. |
ART0114I | Attempting database retry number of total |
Explanation |
The Event Replicator Target Adapter is attempting to reconnect to a source database. The retry attempt number (number) and the total number of retry attempts defined for the source (total) are given in the message. |
Action |
No action is required for this informational message. |
ART0115E | XSLT or XML document is null |
Explanation |
The style sheet (XSLT) or XML document to be used in Event Replicator Target Adapter processing is null or cannot be found. This is an internal error. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0116I | Committing invalid or unprocessed message |
Explanation |
The invalid message was committed because the Commit Unprocessed Message option was set to true. Processing continues. |
Action |
No action is required for this informational message. |
ART0117I | IVP message received and processed |
Explanation |
The installation verification procedure (IVP) message was received and processed successfully. |
Action |
No action is required for this informational message. |
ART0118I | Received count request |
Explanation |
The number of requests received is listed in the message (count). |
Action |
No action is required for this informational message. |
ART0119E | Received unknown message msg |
Explanation |
An unknown message was received. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0120E | Cannot convert input message from source code page num1 to num2 |
Explanation |
The input message listed in the message text could not be converted from one code page (num1) to another (num2). |
Action |
Contact your Software AG technical support representative for assistance. |
ART0121E | Current messages |
Explanation |
This message accompanies message ARTO108E. |
Action |
Review all the messages to determine the cause of the problem. If the problem persists, contact your Software AG technical support representative for assistance. |
ART0122I | Problems writing file; directory must exist: dirname |
Explanation |
A file could not be written because the directory listed in the message did not exist. |
Action |
Create the directory and restart the Event Replicator Target Adapter. |
ART0123E | Unprocessed data count bytes in buffer buf |
Explanation |
An internal error has occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0124I | Successful database reconnect for target target |
Explanation |
An attempt to reconnect to the database target was successful. |
Action |
No action required for this informational message |
ART0125I | Software AG License check license |
Explanation |
A Software AG license check occurred for the license shown in the message. |
Action |
No action required for this informational message |
ART0303I | Initial-state process started for: isname |
Explanation |
The Event Replicator Target Adapter has started processing an initial-state request. The name of the initial-state definition (isname) is listed in the message. |
Action |
No action is required for this informational message. |
ART0304I | Initial-state process completed for: isname |
Explanation |
The Event Replicator Target Adapter has completed processing an initial-state request. The name of the initial-state definition (isname) is listed in the message. |
Action |
No action is required for this informational message. |
ART0305I | Initial-state erroneous request rejected |
Explanation |
An invalid initial-state request was rejected. It was not processed. |
Action |
No action is required for this informational message. However, you might want to review the invalid initial-state request to determine why it was not processed. |
ART0307I | Normal Event Replicator Server session started message received from: reptor-id |
Explanation |
A normal Event Replicator Server session has started and a message has been received from it. The Event Replicator Server ID is listed in the message (reptor-id). |
Action |
No action is required for this informational message. |
ART0308I | Event Replicator Server restart after abnormal end |
Explanation |
The Event Replicator Server has restarted after it ended abnormally. |
Action |
No action is required for this informational message although you might want to review the error messages provided by the Event Replicator Server to determine why it ended abnormally. |
ART0309I | Normal Event Replicator Server session termination message received from: reptor-id |
Explanation |
A normal Event Replicator Server session has terminated. The Event Replicator Server ID is listed in the message (reptor-id). |
Action |
No action is required for this informational message. |
ART0310I | Replication deactivated |
Explanation |
Replication has been deactivated (stopped). |
Action |
No action is required for this informational message. |
ART0311I | Replication reactivated |
Explanation |
Replication has been reactivated (started). |
Action |
No action is required for this informational message. |
ART0314I | Replay process (ADARPL) started |
Explanation |
The ADARPL utility has started to resend replicated data from the database protection log (PLOG) to the target RDBMS. For more information, read about the ADARPL utility in your Event Replicator for Adabas documentation. |
Action |
No action is required for this informational message. |
ART0315I | Replay process (ADARPL) ended |
Explanation |
The ADARPL utility has completed resending replicated data from the database protection log (PLOG) to the target RDBMS. For more information, read about the ADARPL utility in your Event Replicator for Adabas documentation. |
Action |
No action is required for this informational message. |
ART0316I | Event Replicator Server replication definitions refreshed |
Explanation |
The Event Replicator Server replication definitions have been refreshed via an RPLREFRESH command. |
Action |
No action is required for this informational message. |
ART0317I | ADALOD UPDATE started |
Explanation |
A run of the ADALOD UPDATE utility function has started. |
Action |
No action is required for this informational message. |
ART0318I | ADALOD UPDATE ended |
Explanation |
A run of the ADALOD UPDATE utility function has ended. |
Action |
No action is required for this informational message. |
ART0319I | ADALOD LOAD ended. Source: src Target: target |
Explanation |
A run of the ADALOD LOAD utility function has ended. |
Action |
No action is required for this informational message. |
ART0320E | Unknown status message message |
Explanation |
An unknown status message was encountered during Event Replicator Target Adapter processing. The status message is given in the message text. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0321E | Unknown URBS operation operation |
Explanation |
An unknown URBS operation was attempted. The type of operation attempted is listed in the message text. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0322E | Invalid DBID dbid or file number fn |
Explanation |
An invalid database ID or file number was encountered during processing. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0323I | Receiving LODS message: Source: src Target: target |
Explanation |
An LODS message is being received. The data source and target are listed in the message. |
Action |
No action is required for this informational message. |
ART0324E | Receiving unknown message |
Explanation |
An unknown message was received during processing. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0325I | Receiving AUT1 message (Adabas utility execution) |
Explanation |
An AUT1 message produced by the execution of an Adabas utility is being received. |
Action |
No action is required for this informational message. |
ART0401I | Testing database connections |
Explanation |
The Event Replicator Target Adapter is testing its database connections. |
Action |
No action is required for this informational message. |
ART0402I | Database information at startup: |
Explanation |
This message is the introductory message for a series of other informational messages about the databases to which the Event Replicator Target Adapter has connections. |
Action |
No action is required for this informational message. |
ART0403I | Connector protocol: protocol-type port: port |
Explanation |
This message lists the protocol type and port number used by the Event Replicator Target Adapter Tomcat engine. |
Action |
No action is required for this informational message. |
ART0404I | Using connector port: conn-port port: port |
Explanation |
This message lists the default HTTP port number that will be used. |
Action |
No action is required for this informational message. |
ART0405I | Adabas Replicator servlet shutdown started |
Explanation |
The Event Replicator Server is shutting down. |
Action |
No action is required for this informational message. |
ART0406I | Adabas Replicator servlet shutdown complete |
Explanation |
The Event Replicator Server shutdown is complete. |
Action |
No action is required for this informational message. |
ART0407I | Testing connection to database resource id |
Explanation |
A test is being performed that connects to the database resource listed in the message (id). |
Action |
No action is required for this informational message. |
ART0408I | Database testing complete |
Explanation |
Tests on the database have completed. |
Action |
No action is required for this informational message. |
ART0409I | JMS information at startup: |
Explanation |
This message is the introductory message for a series of other informational messages about the JMS to which the Event Replicator Target Adapter has connections. |
Action |
No action is required for this informational message. |
ART0410I | JMS testing complete |
Explanation |
Tests on the JMS have completed. |
Action |
No action is required for this informational message. |
ART0501I | EntireX Broker information info |
Explanation |
This message displays information about a webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter. |
Action |
No action is required for this informational message. |
ART0502I | EntireX Broker source shutdown requested |
Explanation |
A request is being processed to close a webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter. |
Action |
No action is required for this informational message. |
ART0503I | EntireX Broker source shutdown requested; processing: state userstop: xxxx |
Explanation |
A webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter is being closed. The current state of the source is displayed in the message. |
Action |
No action is required for this informational message. |
ART0504I | EntireX Broker source close complete |
Explanation |
A webMethods EntireX source used to convey replicated Adabas data to the Event Replicator Target Adapter has been closed. |
Action |
No action is required for this informational message. |
ART0505I | EntireX Broker UOW rolled back ID: id |
Explanation |
The webMethods EntireX unit of work ID was rolled back. This is an internal process. |
Action |
No action is required for this informational message. |
ART0506I | EntireX Broker prefetch size reached: size |
Explanation |
The defined prefetch size for the webMethods EntireX source has been reached. The defined prefetch size is given in the message (size). |
Action |
No action is required for this informational message. However, you might consider increasing the defined prefetch size. Note that increasing the prefetch size will increase the memory requirements. |
ART0507E | EntireX Broker send error class: class code: code message: msg |
Explanation |
An error has occurred during an attempt to send data to a webMethods EntireX source. The error class (class), message code (code) and message text (msg) are given in the message. |
Action |
Refer to your webMethods EntireX documentation for additional information. |
ART0508E | EntireX Broker error class: class code: code message: msg |
Explanation |
An error has occurred during an attempt to use a webMethods EntireX source. The error class (class), message code (code) and message text (msg) are given in the message. |
Action |
Refer to your webMethods EntireX documentation for additional information. |
ART0509E | EntireX Broker exception: info |
Explanation |
An exception occurred during an attempt to use a webMethods EntireX source. The exception information (info) is given in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0510E | EntireX Broker receive error class: class code: code message: msg |
Explanation |
An error has occurred during an attempt to receive data from an webMethods EntireX source. The error class (class), message code (code) and message text (msg) are given in the message. |
Action |
Refer to your webMethods EntireX documentation for additional information. |
ART0511E | EntireX Broker logon error ID: class service: service message: msgtxt |
Explanation |
An error has occurred during an attempt to log into an webMethods EntireX source. The error class (class), service name (service), and message code (msgtxt) are given in the message. |
Action |
Verify that the correct logon information (user ID, token, and password) is provided in the webMethods EntireX source definition. Correct it as necessary and try again. |
ART0512E | EntireX Broker error on: id cause: exx-cause |
Explanation |
An error occurred during an attempt to use the webMethods EntireX source whose ID is listed in the message (id). The cause of the error is also listed in the message (exx-cause). |
Action |
Contact your Software AG technical support representative for assistance. |
ART0513E | EntireX Broker commit error message: err-msg |
Explanation |
An error occurred during an attempt to use a webMethods EntireX source definition. The webMethods EntireX error message (err-msg) is listed in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0514E | EntireX Broker cannot open Broker trace log file: fn |
Explanation |
An error occurred during an attempt to open the webMethods EntireX trace log file. The file name of the log file is given in the message (fn). |
Action |
Verify that the correct file name is specified for the webMethods EntireX trace log file in the webMethods EntireX definitions. If it is not, correct the name and try again. If the problem persists, contact your Software AG support representative for assistance. |
ART0515I | EntireX Broker trace level: lvl trace file: fn |
Explanation |
This message identifies the trace level (lvl) and file name (fn) used by the Event Replicator Target Adapter for webMethods EntireX sources. |
Action |
No action is required for this informational message. |
ART0516I | EntireX Broker receive complete: time: count Ms length: length UowStatus: status |
Explanation |
A webMethods EntireX source received data from replication. The length of time (in microseconds) for the receive operation (count), the length of the data received (length), and the unit of work status of the receive operation (status) are given in the message. Values for the unit of work status are "First", "Middle" or "Last". |
Action |
No action is required for this informational message. |
ART0517E | EntireX Broker commit error class: class code: code uowid: uowid message: msg |
Explanation |
An error occurred during a commit attempt for the webMethods EntireX source. The error class (class), EntireX message code (code), EntireX UOWID (uowid) and EntireX message text (msg) are listed in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0518E | EntireX Broker rollback error class: class code: code message: msg |
Explanation |
An error occurred during a rollback attempt for the webMethods EntireX source. The error class (class), EntireX message code (code) and EntireX message text (msg) are listed in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0519E | EntireX Broker deregister error host: host-id service: service message: msg |
Explanation |
An error occurred during an attempt to deregister a webMethods EntireX source. The EntireX ID (host-id), service (service) and message text (msg) are listed in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0520E | EntireX Broker user ID required |
Explanation |
A valid webMethods EntireX user ID is required but was not supplied. |
Action |
Supply a valid webMethods EntireX user ID and try again. |
ART0521E | EntireX Broker token required |
Explanation |
A valid webMethods EntireX token is required but was not supplied. |
Action |
Supply a valid webMethods EntireX token and try again. |
ART0601I | Save file fn with data: dddd |
Explanation |
An attempt to save the file listed in the message (fn) with the data listed in the message (dddd) was successful. |
Action |
No action is required for this informational message. |
ART0602E | Read resource failed for: resource-id status code: code |
Explanation |
An attempt to read from the resource listed in the message (resource-id) failed. The status code of the attempt is given in the message (code). |
Action |
Contact your Software AG technical support representative for assistance. |
ART0603I | Retrying resource read for: resource-id |
Explanation |
An attempt is being made to read from the resource listed in the message (resource-id). |
Action |
No action is required for this informational message. |
ART0604E | WebDAV error: err-code |
Explanation |
A WebDAV error occurred during Event Replicator Target Adapter processing. |
Action |
Verify that the web service target URL is correct and try again. If the problem persists, contact your Software AG technical support representative. |
ART0605E | WebDAV repository is not accessible err-code |
Explanation |
The WebDAV repository cannot be accessed. |
Action |
Verify that the web service target URL is correct and try again. If the problem persists, contact your Software AG technical support representative. |
ART0606E | Invalid WebDAV cache size value size |
Explanation |
An invalid WebDAV cache size has been specified. The value was not numeric. |
Action |
Supply a valid numeric cache size and try again. |
ART0607E | Cannot find generic XSLT file filename |
Explanation |
The XSLT file listed in the message (filename) could not be found. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0608E | Cannot find XSLT file filename |
Explanation |
The XSLT file listed in the message (filename) could not be found. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0609E | Create table XML message is null or base table name is null |
Explanation |
An internal error has occurred. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0610E | Cannot convert create table schema to string |
Explanation |
An internal error has occurred. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0611E | Cannot save create table schema name into WebDAV |
Explanation |
An attempt to save the schema named in the message (name) to the WebDAV repository failed. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0612E | Problem with managing WebDAV file filename |
Explanation |
The WebDAV file named in the message (filename) could not be managed. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0613I | Collection may not exist colname |
Explanation |
The collection named in the message (colname) may not exist in the WebDAV repository. The collection is created. |
Action |
No action is required for this informational message. |
ART0614I | Retrying resource write for res |
Explanation |
An attempt is in progress to retry the resource write for the resource named in the message (res). |
Action |
No action is required for this informational message. |
ART0615E | Write resource file fn failed err-code |
Explanation |
An attempt to write the resource file named in the message (fn) failed. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0616E | WebDAV status code code status message msg |
Explanation |
A WebDAV internal error has occurred. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0617E | Make collection colname failed status stat |
Explanation |
An attempt to make the collection named in the message (colname) failed. The status of the attempt is also given in the message (stat). |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0701I | Source shutdown complete |
Explanation |
An attempt to shut down a source completed successfully. |
Action |
No action is required for this informational message. |
ART0702I | Source waiting for restart after user stop or rollback |
Explanation |
The source is waiting to be restarted after it was manually stopped or after a rollback occurred. |
Action |
No action is required for this informational message. Restart the source when you are ready. |
ART0703I | Retries = 0; source waiting for manual restart |
Explanation |
The value of the |
Action |
No action is required for this informational message. Manually restart the source when you are ready. |
ART0704I | Wait for retry; count: count |
Explanation |
The source is waiting between retry attempts. The retry attempt count is given in the message (count). |
Action |
No action is required for this informational message. |
ART0705E | No commit/rollback listener |
Explanation |
An internal error has occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0706E | Source message is null on commit |
Explanation |
An internal error has occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0707E | Unsupported source type type |
Explanation |
An internal error has occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART0708E | Cannot open source capture file fn |
Explanation |
The file cannot be opened. Verify that the directory name exists. |
Action |
If the problem persists, contact your Software AG technical support representative. |
ART0801I | Runtime metrics |
Explanation |
This message is the heading message for a series of runtime metric messages. |
Action |
No action is required for this informational message. |
ART0802I | Resource key: rkey |
Explanation |
A resource key is listed in the message (rkey). |
Action |
No action is required for this informational message. |
ART0803I | Metrics key: mkey |
Explanation |
A metrics key is listed in the message (mkey). |
Action |
No action is required for this informational message. |
ART0901E | Process request failed |
Explanation |
An Event Replicator Target Adapter process request failed. The source is shut down. |
Action |
Review any accompanying error messages to determine the cause of the problem. If the problem persists, contact your Software AG technical support representative. |
ART0902I | Database active result: result |
Explanation |
The result of a test to see whether the database is active or not is listed in the message (result). |
Action |
No action is required for this informational message. |
ART0903I | Retrying Database Transaction |
Explanation |
An attempt is in progress to retry the database transaction. |
Action |
No action is required for this informational message. |
ART1001E | Exception cause: cause |
Explanation |
An Event Replicator Target Adapter process request failed. The cause of the failure is given in the message (cause). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1002E | Exception stack: stack |
Explanation |
An Event Replicator Target Adapter process request failed. The exception stack for the failure is given in the message (stack). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1005W | Unable to transform document |
Explanation |
The Event Replicator Target Adapter was unable to transform a document. |
Action |
No action is required for this warning message. Determine the reason for which the Event Replicator Target Adapter cannot transform the document and alter the conditions as necessary. Then try again. |
ART1101I | File source configured for input directory: dirname |
Explanation |
A file source definition has been configured for the input directory listed in the message (dirname). |
Action |
No action is required for this informational message. |
ART1102I | File source ready to receive data from: dirname |
Explanation |
A file source definition is ready to receive data from the directory listed in the message (dirname). |
Action |
No action is required for this informational message. |
ART1103E | File source unable to get list of files |
Explanation |
A file source could not get a list of the files from the source. |
Action |
Determine why a list of files could not be obtained. Resolve the error and try again. If the problem persists, contact your Software AG support representative for assistance. |
ART1104I | File source closing |
Explanation |
A file source is closing. |
Action |
No action is required for this informational message. |
ART1105I | File source returning file: FILE: dirname-->fn |
Explanation |
The file source definition is returning the file source as part of the file source shutdown execution. The directory (dirname) and filenamefn) are given in the message. |
Action |
No action is required for this informational message. |
ART1106I | File source shutdown requested |
Explanation |
Shutdown of a file source was requested. |
Action |
No action is required for this informational message. |
ART1107I | File source rollback called |
Explanation |
Rollback of the updates from a file source was called. |
Action |
No action is required for this informational message. |
ART1108E | File source file does not exist fn |
Explanation |
The file source file named in the message (fn) does not exist. This is an internal message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1109I | File source processing time for: dirname-->fn is num MilliSeconds |
Explanation |
The processing time is given in the message for the file identified in the message. |
Action |
No action is required for this informational message. |
ART1201I | Rollback following SQL commands |
Explanation |
A rollback occurred based on SQL commands. |
Action |
No action is required for this informational message. |
ART1203W | File name not provided for operation: op FNR: fnum ISN: isnnum |
Explanation |
A file name was not provided for the operation listed in the message (op). The file (fnum) and ISN (isnnum) numbers are also listed in the message. |
Action |
No action is required for this informational message. |
ART1204E | Test connection failed: conn-name |
Explanation |
A test connection to the connection listed in the message (conn-name) failed. |
Action |
Restart the database if it is down. |
ART1205E | Cannot get a connection from the data source |
Explanation |
An attempt to connect to a data source failed. |
Action |
Review the data source definition and try again. If the problem persists, contact your Software AG technical support representative for assistance. |
ART1206E | Cannot get metadata |
Explanation |
An attempt to connect to a data source failed. |
Action |
Review the data source definition and try again. If the problem persists, contact your Software AG technical support representative for assistance. |
ART1207E | Exception obtaining table metadata: tablename |
Explanation |
An exception occurred while the Event Replicator Target Adapter was attempting to obtain metadata from a table. The name of the table is given in the message (tblname). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1208I | Process is continuing after the previous error |
Explanation |
Event Replicator Target Adapter processing is continuing in spite of a previously reported error condition. |
Action |
No action is required for this informational message. |
ART1209I | Unable to locate table: tablename |
Explanation |
The Event Replicator Target Adapter could not locate the table listed in the message (tablename). |
Action |
No action is required for this informational message. If you really do need the Event Replicator Target Adapter to locate this table, determine why it cannot be located and try again. If the problem persists, contact your Software AG technical support representative. |
ART1210I | Create index command built: cmd |
Explanation |
An internal command to create the index to a table was successfully built. |
Action |
No action is required for this informational message. |
ART1211E | Cannot get connection to data source name |
Explanation |
An attempt to connect to the data source named in the message (name) failed. |
Action |
Verify that the database definitions are correct and that the database is active. |
ART1212E | Cannot retrieve database metadata |
Explanation |
An attempt to retrieve metadata for the database failed. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1213E | Internal error of Sybase ASE |
Explanation |
An internal error occurred in Sybase ASE |
Action |
Contact your Software AG technical support representative for assistance. |
ART1214W | Unknown data type type for column colname in metadata |
Explanation |
An attempt was made to specify the unknown data type listed in the message (type) in the column listed in the message (colname). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1215E | pkTableName pkname does not match with table name tblname |
Explanation |
A mismatch has occurred between the table and the primary key. The table name (tblname) and the primary key (pkname) are given in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1216E | Cannot find previous column information |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1217F | Initial context is null |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1218F | Context lookup is null |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1219E | Unsupported driver class name for JDBC/database dbname |
Explanation |
An unsupported driver class name was specified for the JDBC database listed in the message (dbname). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1220E | Error obtaining connection err-code |
Explanation |
A connection to the database could not be made. |
Action |
Verify that the database definitions are correct and that the database is active. |
ART1221E | Table tblname has duplicate column name colname |
Explanation |
The table named in the message (tblname) has two columns with the same name (colname). |
Action |
Change one of the column names and try again. |
ART1222E | Cannot create statement |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1223E | Cannot connect to database dbname |
Explanation |
An attempt to connect to the database named in the message (dbname) failed. |
Action |
Verify that the database definitions are correct and that the database is active. |
ART1224E | Cannot execute batch |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1225E | Cannot turn off database autocommit |
Explanation |
An attempt to turn off the autocommit feature of the database failed. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1226E | Cannot create executing SQL statement |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1227E | Process continuing because dbErrorContinue is TRUE |
Explanation |
The target database Error Continue option was set to "true" (selected or turned on), so the SQL error is ignored and processing continues. |
Action |
No action is required for this message. |
ART1228E | Executing....<processing information> |
Explanation |
An SQL command either failed or executed successfully. The SQL command and details about its processing are given in the message (<processing information>). If an error occurred, and you have not selected the Error Continue option for the target database, the Event Replicator Target Adapter will stop running. For more information, read Specifying Target Database Processing Option Definitions. |
Action |
If the command failed, resolve the error described in the message. If necessary, contact your Software AG technical support representative for assistance. |
ART1229E | Unable to load/construct DB support class for classname |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1230E | Update to insert mode is on but full image value is missing |
Explanation |
An attempt to insert an update failed because the full image of the record is missing from the database. |
Action |
Use Option=32 in the Event Replicator Server destination definition. For more information, refer to your Event Replicator for Adabas destination documentation. |
ART1232E | Cannot insert column |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1233I | SQL command failed cmd |
Explanation |
The SQL command listed in the message (cmd) failed. |
Action |
Review other accompanying error messages to determine the cause of the problem. If the problem persists, contact your Software AG technical support representative for assistance. |
ART1234I | SQL command reason rsncode |
Explanation |
The previous SQL command failed with the reason code (rsncode) given in the message. |
Action |
Review the documentation for your RDBMS to determine the cause of the problem. |
ART1235W | Sync DDL value val is not one of the following values, ignore, warn, apply, error. Reset to ignore. |
Explanation |
The value for the Adabas-RDBMS Synchronization Level option is invalid. It has been reset to "ignore". |
Action |
In the target database options, change the setting of the Adabas-RDBMS Synchronization Level option to something other than "ignore" if you want. |
ART1236E | Cannot alter column detailed-info |
Explanation |
The Event Replicator Target Adapter could not alter the column described by the detailed information listed in the message (detailed-info) during it's attempt to synchronize the RDBMS table with the Adabas file. |
Action |
Make sure the target database supports this kind of type conversion and that this column is not a primary key and doesn’t have foreign key. If the problem persists, contact your Software AG technical support representative for assistance. |
ART1237W | Data type or length mismatch on column detailed-info |
Explanation |
During an attempt to synchronize the RDBMS table with the Adabas file, the Event Replicator Target Adapter determined that a data type or length mismatch had occurred for the column described by the detailed information listed in the message (detailed-info). |
Action |
Issue the same message as the previous one. The Event Replicator Target Adapter will continue to run because the Adabas-RDBMS Synchronization Level value is set to "warn". If the problem persists, contact your Software AG technical support representative for assistance. |
ART1238I | Alter column detailed-info |
Explanation |
The column described by the detailed information listed in the message (detailed-info) was altered in the RDBMS during Event Replicator Target Adapter synchronization between the RDBMS table and the Adabas file. |
Action |
No action is required for this informational message. |
ART1239I | Add column detailed-info |
Explanation |
The column described by the detailed information listed in the message (detailed-info) was added to the RDBMS during Event Replicator Target Adapter synchronization between the RDBMS table and the Adabas file. |
Action |
No action is required for this informational message. |
ART1240E | Cannot add column detailed-info |
Explanation |
The Event Replicator Target Adapter could not add the column described by the detailed information listed in the message (detailed-info) to the RDBMS during it's attempt to synchronize the RDBMS table with the Adabas file. |
Action |
Make sure the target database supports adding columns. If the problem persists, contact your Software AG technical support representative for assistance. |
ART1241W | Target database doesn't have column detailed-info |
Explanation |
During an attempt to synchronize the RDBMS table with the Adabas file, the Event Replicator Target Adapter determined that the target RDBMS is missing the column described by the detailed information listed in the message (detailed-info). This message is issued because the Adabas-RDBMS Synchronization Level value is set to "warn". In this case, the Event Replicator Target Adapter issues this warning message and continues processing. |
Action |
No action is required for this warning message. |
ART1242E | Cannot find _INDEX as suffix of the PE table tablename primary key key |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1302I | Loader complete for loader |
Explanation |
The Event Replicator Target Adapter completed loading replicated data for the Oracle SQL Loader listed in the message without failing. |
Action |
No action is required for this informational message. |
ART1303E | Loader fail. Please check the log files fn |
Explanation |
An attempt to load replicated data to the database via the Oracle SQL loader failed. The log files (fn) that contain more information are listed in the message. |
Action |
Review the log files for more information about the failure. If possible, correct the error and try again. If the problem persists, contact your Software AG technical support representative for assistance. |
ART1304E | Loader exception |
Explanation |
An exception occurred during the loading process. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1305E | Create table XML file fn does not exist |
Explanation |
A request to create the table in an XML file failed because the XML file could not be found. The filename of the XML file is given in the message (fn). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1307E | Control file fn is not generated |
Explanation |
The control file listed in the message (fn) was not generated. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1308E | Loader cannot support streaming mode |
Explanation |
The loader cannot support streaming mode. |
Action |
Modify the target database options used by the database so that the Use Stream option is not selected (checked) and try again. For more information, read Specifying Target Database Processing Option Definitions. |
ART1309E | Output file fn is not generated |
Explanation |
The output file named in the message (fn) was not generated. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1310I | Current configuration cannot support streaming mode; change to nonstreaming mode |
Explanation |
The current configuration does not support streaming mode. The Event Replicator Target Adapter turns stream mode off and retries the operation. |
Action |
No action is required for this informational message. |
ART1311I | Current configuration cannot support loader mode; change to nonloader mode |
Explanation |
The current configuration does not support the database in loader mode. |
Action |
No action is required for this informational message. |
ART1312I | Loader process running for loader |
Explanation |
The database loader process is running for the Oracle SQL Loader listed in the message. |
Action |
No action is required for this informational message. |
ART1313I | Loader about to execute following command: cmd |
Explanation |
The database loader process is executing the command listed in the message (cmd). |
Action |
No action is required for this informational message. |
ART1315I | Create loader thread |
Explanation |
An attempt by the Event Replicator Target Adapter to create a loader thread is in process. |
Action |
No action is required for this informational message. |
ART1316E | Called with table: tblname column: colname |
Explanation |
An error occurred trying to call the table (tblname) and column (colname) whose names are listed in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1318I | Initial-state running in loader mode |
Explanation |
The initial-state process is running in loader mode. |
Action |
No action is required for this informational message. |
ART1319E | Cannot wait for loader process |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1320E | Cannot find control file name |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1321E | Cannot find log file name |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1322E | Cannot find bad file name |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1323E | Cannot find discard file name |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1324E | Cannot find out file name |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1325E | Create loader process failed |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1326I | Test loader process successful |
Explanation |
The test loader process completed successfully. |
Action |
No action is required for this informational message. |
ART1327E | Test loader process failed, exit code code |
Explanation |
The test loader process failed with the exit code listed in the message (code). |
Action |
Contact your Software AG technical support representative for assistance. |
ART1328E | Cannot create XsltWorker |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1329E | Cannot set up environment variables of file fn |
Explanation |
An attempt to set the environment variables for the file named in the message (fn) failed. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1330E | Cannot support current database type |
Explanation |
Support is not provided for the database type. |
Action |
Change the database type to one that is supported by the Event Replicator Target Adapter. If necessary, contact your Software AG technical support representative for assistance. |
ART1331E | Worker is null |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1332E | Cannot create loader thread |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1333E | Cannot create piped stream |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1334E | Loader failed. Current mode is streaming mode, change to nonstreaming mode and retry |
Explanation |
The loader failed. |
Action |
Modify the target database options used by the database so that the Use Stream option is not selected (checked) and try again. For more information, read Specifying Target Database Processing Option Definitions |
ART1335E | Cannot write to output stream |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1336E | Parsing error err line lll column ccc PID pid CID cid |
Explanation |
A parsing error occurred. The error, line number, column number, process ID, and command ID are given in the message. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1337E | Unable to send message to the loader |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1338E | Cannot find base file name |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1339W | Current database cannot support streaming mode, reset to nonstreaming mode |
Explanation |
The current database does not support streaming mode. The Event Replicator Target Adapter has turned streaming mode off. |
Action |
No action is required for this warning message. |
ART1340E | The child thread may end unexpectedly |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1341E | Cannot find WebDAV |
Explanation |
The WebDAV file cannot be found. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1342E | Batch file fn does not exist |
Explanation |
The batch file named in the message does not exist. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1343W | The service name of the loader in the Target Database Options of a Teradata MLoad, name, has more than num characters. Using xxxx as the tdpid for this MLoad |
Explanation |
The service name of the loader during Teradata MLoad processing is too long. The Event Replicator Target Adapter is using the name xxxx for the tdpid of the MLoad processing. |
Action |
No action is required for this warning message. |
ART1344W | The service name of the loader in the Target Database Options of a Teradata MLoad has not been informed. Attempting to use xxxx as the tdpid for ths MLoad |
Explanation |
The service name of the loader during Teradata MLoad processing has not been provided. The Event Replicator Target Adapter is trying to use the name xxxx for the tdpid of the MLoad processing. |
Action |
No action is required for this warning message. |
ART1401I | Transform document using XSLT file: fn token: token |
Explanation |
The Event Replicator Target Adapter is attempting to transform the document using the XSLT file (fn) and token (token) listed in the message. |
Action |
No action is required for this informational message. |
ART1402E | Cannot convert from UTF8 byte array to a string |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART1501I | Source manager shutdown requested |
Explanation |
A request was made to shut down the source manager. |
Action |
No action is required for this informational message. |
ART1502I | Source manager notified to shut down |
Explanation |
The source manager has been notified to shut down. |
Action |
No action is required for this informational message. |
ART1503I | Waiting for source manager shutdown to complete |
Explanation |
The Event Replicator Target Adapter is waiting for the source manager to fully shut down. |
Action |
No action is required for this informational message. |
ART1504I | Source manager is down |
Explanation |
The source manager shutdown has completed. |
Action |
No action is required for this informational message. |
ART1601I | Engine manager shutdown requested |
Explanation |
A request was made to shut down the engine manager. |
Action |
No action is required for this informational message. |
ART1602I | Engine manager notified to shut down |
Explanation |
The engine manager has been notified to shut down. |
Action |
No action is required for this informational message. |
ART1603I | Waiting for engine manager shutdown to complete |
Explanation |
The Event Replicator Target Adapter is waiting for the engine manager to fully shut down. |
Action |
No action is required for this informational message. |
ART1604I | Engine manager is down |
Explanation |
The engine manager shutdown has completed. |
Action |
No action is required for this informational message. |
ART1701W | Parameter parm value val not numeric |
Explanation |
The parameter named in the message (parm) specifies a value (val) that is not numeric. |
Action |
Supply a numeric value for the parameter and try again. |
ART1702W | Parameter parm value val does not end with "S" |
Explanation |
The parameter named in the message (parm) specifies a value (val) that does not end in an "S". |
Action |
Supply a value for the parameter that ends in an "S" and try again. |
ART1703W | Parameter parm value val is not "true" or "false" |
Explanation |
The parameter named in the message (parm) specifies a value (val) that is not "true" or "false." |
Action |
Supply a "true" or "false" value for the parameter and try again. |
ART1801E | Cannot open WebSphere MQ trace log file fn |
Explanation |
An attempt to open the WebSphere MQ trace file named in the message (fn) failed. |
Action |
Check your definition. Verify that the directory defined in your definitions exists. |
ART1802E | WebSphere MQ rollback failed err-code |
Explanation |
A rollback attempt for WebSphere MQ failed. |
Action |
Review the webSphere MQ documentation to determine the reason for the failure. |
ART1803E | WebSphere MQ logon failed host hostid port portnum error err |
Explanation |
An attempt to logon to WebSphere MQ failed. The WebSphere MQ host ID (hostid), port number (portnum), and the error number (err) from the attempt are given in the message. |
Action |
Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again. |
ART1804I | WebSphere MQ logon to host hostid successful |
Explanation |
The attempt to log onto the WebSphere MQ host named in the message (hostid) was successful. |
Action |
No action is required for this informational message. |
ART1805I | WebSphere MQ receiving messages from queue qname |
Explanation |
WebSphere MQ is receiving and processing messages from the queue listed in the message (qname). |
Action |
No action is required for this informational message. |
ART1806E | WebSphere MQ request failed |
Explanation |
A WebSphere MQ request failed. |
Action |
Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again. |
ART1807E | WebSphere MQ receive failed err-code |
Explanation |
A receive request via the WebSphere MQ queue failed. |
Action |
Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again. |
ART1808E | WebSphere MQ commit failed err-code |
Explanation |
A commit request via the WebSphere MQ queue failed. |
Action |
Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again. |
ART1809E | WebSphere MQ send failed err-code |
Explanation |
A send request via the WebSphere MQ queue failed. |
Action |
Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again. |
ART1810E | WebSphere MQ close failed err-code |
Explanation |
A close request via the WebSphere MQ queue failed. |
Action |
Check with your WebSphere MQ administrator to determine why the attempt failed. Resolve the problem and try again. |
ART2001E | Required target configuration not found config or default |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART2002E | Operation is null |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART2003E | Operation opname is not supported |
Explanation |
An attempt to run the operation named in the message (opname) failed because it is not supported. |
Action |
Try an operation that is supported. |
ART2004E | Not SOAP element |
Explanation |
An internal error occurred. |
Action |
Contact your Software AG technical support representative for assistance. |
ART3001E | Wrong factory type for msgtype. Type is factype. |
Explanation |
An attempt to use the wrong JMS factory type for the type of messaging specified. The message type (msgtype) and factory type (factype) are given in the message. Replicate the data to a JMS topic if you want to use publish-subscribe messaging; replicate the data to a JMS queue if you want to use point-to-point messaging. |
Action |
Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance. |
ART3002E | Factory factory not found in the naming system. |
Explanation |
An attempt to access the JMS topic or queue connection factory in the system was not successful. |
Action |
Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance. |
ART3003E | Error occurred while accessing factory factory in the naming system system. |
Explanation |
An error occurred attempting to access the JMS topic or queue connection factory named in the message in the system named in the message. |
Action |
Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance. |
ART3004E | Wrong destination type for jmsname. Type is factype. |
Explanation |
An attempt to use the wrong type of destination was made when replicating data to JMS queues or topics. The JMS destination topic or queue name (jmsname) and the factory type (factype) are given in the message. Specify the destination as a JMS topic (as defined to webMethods Broker) if you want to use publish-subscribe messaging; specify the destination as a JMS queue (as defined to webMethods Broker) if you want to use point-to-point messaging. |
Action |
Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance. |
ART3005E | Destination dest not found in the JNDI provider |
Explanation |
An internal error occurred. The destination specified in the JMS target definition was not found in the JNDI provider specified in the JMS target definition. The destination name is given in the message. |
Action |
Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance. |
ART3006E | Error while accessing destination dest |
Explanation |
An internal error occurred. An error occurred during an attempt to access the destination specified in the JMS target definition. |
Action |
Verify the JMS target definition is specified correctly in the Event Replicator Target Adapter Administration tool. Contact your Software AG technical support representative for assistance. |