ERROR-121 | ERROR-123 | ERROR-124 | ERROR-125 | ERROR-127 | ERROR-128 | ERROR-130 | ERROR-131 | ERROR-132 | ERROR-133 | ERROR-134 | ERROR-135 | ERROR-136 | ERROR-137
ERROR-121 | Invalid record length found | |
Explanation |
The record length is negative, zero, or greater than the permitted maximum (MAXRECL value).
|
ERROR-123 | Duplicate ISN found | |
Explanation |
The same ISN is found twice in the same DS block.
|
ERROR-124 | Invalid DSST entry found | |
Explanation |
The following information is provided to identify the error:
Block size minus padding = xxxx (nnn) Size of block in use = xxxx (nnn) |
ERROR-125 | Invalid record length | |
Explanation |
The DSCHECK function found that either the sum of all record lengths in one Data Storage block is not equal to the block length minus 4; or that the record length is zero.
|
ERROR-127 | Invalid block length | |
Explanation |
The block length field contains either
|
ERROR-128 | Invalid ISN found |
Explanation |
An ISN was detected that is either zero or greater than the maximum allowed (TOPISN) value. |
ERROR-130 | Spanned record with ISN isnnumber DS RABN rabn One of the following errors occurred: Neither primary spanned record bit nor secondary spanned record bit is switched on. |
Explanation |
The header of the spanned record with the ISN number listed in the message (isnnumber) is erroneous. |
Action |
Correct the ISN or the ISN of the next spanned record or switch on the primary spanned record bit or the secondary spanned record bit (but not both). To correct the header of a spanned record, contact your Software AG technical support representative. |
ERROR-131 | Spanned data storage record with ISN isnnumber DS RABN rabn contains inconsistencies. One of the following errors occurred: ISN of next secondary spanned record is zero. Bits of secondary spanned record and primary record are both switched on. |
Explanation |
The header of the primary spanned record with the ISN number listed in the message (isnnumber) is erroneous. |
Action |
Correct the ISN of the primary spanned record, correct the ISN of the next secondary spanned record, or switch off the secondary spanned record bit. To correct the header of a spanned record, contact your Software AG technical support representative. |
ERROR-132 | Secondary spanned record with ISN isnnumber not found. |
Explanation |
The header of the secondary spanned record with the ISN number listed in the message (isnnumber) cannot be found in Data Storage. |
Action |
Contact your Software AG technical support representative for assistance. |
ERROR-133 | Duplicate primary spanned DS ISN isnnumber found - DS RABN rabn |
Explanation |
The ISN number listed in the message (isnnumber) appears in two primary spanned records in Data Storage. ISNs should be unique. |
Action |
Contact your Software AG technical support representative for assistance. |
ERROR-134 | Duplicate secondary spanned DS ISN isnnumber found - DS RABN rabn |
Explanation |
The ISN number listed in the message (isnnumber) appears in two secondary spanned records in Data Storage. ISNs should be unique. |
Action |
Contact your Software AG technical support representative for assistance. |
ERROR-135 | Secondary spanned record with ISN isnnumber1 not found. Secondary ISN isnnumber2 DSRABN rabn points to secondary ISN which was not found in data storage |
Explanation |
The ISN for a secondary spanned record listed in the message (isnnumber1) could not be found in Data Storage. The ISN of the secondary spanned record that points to this ISN is also given in the message (isnnumber2). |
Action |
Contact your Software AG technical support representative for assistance. |
ERROR-136 | Secondary ISN isnnumber found in Data Storage RABN rabn but not referenced by a primary ISN. |
Explanation |
A secondary spanned record was found in Data Storage is not referenced by a primary ISN. The ISN of the secondary spanned record is given in the message (isnnumber). |
Action |
Contact your Software AG technical support representative for assistance. |
ERROR-137 | Primary ISN isnnumber1 not found. Primary ISN was referenced in secondary ISN isnnumber2 DS RABN rabn - removing from the FROMRABN/TORABN will most likely resolved the warning. |
Explanation |
The ISN for a primary spanned record that was referenced by a secondary spanned record was not found in Data Storage during the ADADCK run. The ISN numbers for both the primary spanned record (isnnumber1) and the secondary spanned record (isnnumber2) are given in the message. The most likely cause of this error is that the FROMRABN and TORABN parameters were specified for the ADADCK run and the FROMRABN parameter references a secondary RABN rather than a primary RABN. We recommend that the FROMRABN parameter reference a primary RABN instead. |
Action |
If you have used the FROMRABN parameter, verify that it points to a primary RABN and not a secondary RABN. Then try the job again. You might also consider removing the FROMRABN and TORABN parameters from the run. If problems persist, contact your Software AG technical support representative for assistance. |