During Data Archiving for Adabas operation, the following response codes may be received:
Response Code | Issued By | Message Format | Description |
---|---|---|---|
101 | Adabas System Coordinator | Error: COR Subcode: nnnnnnnnnnn | See the Adabas System Coordinator Messages and Codes documentation. |
248 | Data Archiving for Adabas | Error: ADR Subcode: nnnnnnnnnnn | See Section Response Code 248 |
Other Response Codes | Adabas | Error: nnn Subcode: nnnnnnnnnnn | See the Adabas Messages and Codes documentation. |
This section describes the Data Archiving for Adabas response code 248 subcodes returned in the rightmost two bytes of the Additions 2 field of the Adabas control block when a processing error occurs.
Response 248 | Subcode 0x0000 – 0xFFFF |
1 (0x0001)... | |
Explanation |
No architecture/version information returned by Adabas in the response
to the |
Action |
Contact Software AG Support. |
2 (0x0002) | |
Explanation |
Cannot recall archived data because the architecture of the target database is not compatible with the architecture to the original database. |
Action |
Choose a different mixture. |
3 (0x0003) | |
Explanation |
Either the Extractor/Accumulator versions are not compatible or the Adabas version of the database being archived from or recalled to is not supported. |
Action |
Contact Software AG Support. |
4 (0x0004) | |
Explanation |
The FDT of the file into which data is being recalled or archived is not compatible with the FDT of the original file. |
Action |
Check that FDTs of the files are compatible. |
5 (0x0005) | |
Explanation |
Cannot coerce a value specified for the extraction criteria to the specified type. |
Action |
Check that the values and types defined for the extraction criteria are correct. |
6 (0x0006) | |
Explanation |
Date specified for the extraction criteria is prior to the earliest supported data. |
Action |
Contact Software AG Support. |
7 (0x0007) | |
Explanation |
Unsupported date/time pattern in extraction critiera. |
Action |
Set a correct pattern in the extraction criteria. Contact Software AG Support. |
8 (0x0008) | |
Explanation |
Database from which data is being archived or recalled into is not on the local machine. The source database must be local to the Extractor and target database local to the Accumulator. |
9 (0x0009) | |
Explanation |
Cannot load the Adabas System Coordinator library. |
Action |
Check that Adabas System Coordinator is installed correctly. |
10 (0x000A)... | |
Explanation |
An incompatible version of Adabas System Coordinator is installed. |
Action |
Contact Software AG Support. |
11 (0x000B) | |
Explanation |
An incompatible version of Adabas System Coordinator is installed. |
Action |
Contact Software AG Support. |
12 (0x000C) | |
Explanation |
Cannot parse FDT. |
Action |
Contact Software AG Support. |
13 (0x000D) | |
Explanation |
Cannot generate FDU from FDT. |
Action |
Contact Software AG Support. |
14 (0x000E) | |
Explanation |
Cannot create format buffer for the whole FDT. |
Action |
Contact Software AG Support. |
15 (0x000F) | |
Explanation |
PE or MU field(s) not defined correctly. |
Action |
Check that the PE/MU fields in the Extractor/Accumulator filtering and Archive search fields are defined correctly. |
16 (0x0010) | |
Explanation |
Field does not exist in the FDT. |
Action |
Check that the fields in the Extractor/Accumulator filtering and Archive search fields are defined correctly. |
17 (0x0011) | |
Explanation |
Recall of a filtered archive using the ‘Replace duplicate unique descriptors’ option failed because the format/record buffer could not be parsed. |
Action |
Contact Software AG Support. |
18 (0x0012) | |
Explanation |
Recall of a filtered archive using the ‘Replace duplicate unique descriptors’ option failed because the conflicting descriptor does not appear in the format/record buffer. |
Action |
Choose different recall options for handling duplicate unique descriptors or ensure that all UQ fields are included in a filtered archive. |
19 (0x0013) | |
Explanation |
Internal record buffer overflow. |
Action |
Contact Software AG Support. |
20 (0x0014) | |
Explanation |
Internal format buffer overflow. |
Action |
Contact Software AG Support. |
21 (0x0015) | |
Explanation |
Internal search buffer overflow. |
Action |
Contact Software AG Support. |
22 (0x0016) | |
Explanation |
Internal value buffer overflow. |
Action |
Contact Software AG Support. |
23 (0x0017) | |
Explanation |
No extraction criteria were specified and there are no DE fields in the FDT. |
Action |
Contact Software AG Support. |
24 (0x0018) | |
Explanation |
No Computer record for the current Adabas System Coordinator Group Leader. |
Action |
Check that the correct Configuration File is being used and that the Adabas System Coordinator Computer is still defined. |
25 (0x0019) | |
Explanation |
No archive service definition for the Extractor/Accumulator computer. |
Action |
Check that the correct Configuration File is being used and that the Data Archiving Service is still defined for Adabas System Coordinator Daemon. |
26 (0x001A) | |
Explanation |
No Computer or Daemon record for the Extractor/Accumulator computer. |
Action |
Check that the correct Configuration File is being used and that the Adabas System Coordinator Computer and Daemon is still defined. |
27 (0x001B) | |
Explanation |
No Action record found for the current archive/recall/search operation. |
Action |
Check that the correct Configuration File is being used and that the Action record is still defined. |
28 (0x001C) | |
Explanation |
No Activity record found for the current archive/recall/search operation. |
Action |
Check that the correct Configuration File is being used and that the Activity has not been deleted. |
29 (0x001D) | |
Explanation |
No Vault PATH information for this computer. |
Action |
Check that a Vault Path is defined for the Extractor, Accumulator and ADR Service computers. |
30 (0x001E) | |
Explanation |
Attempt to recall an archive using Extractor/Accumulator computers that not sharing the same Configuration File. |
Action |
Extractor/Accumulator computers for a recall must share the same Configuration File. |
31 (0x001F) | |
Explanation |
No Plan record found for the current archive/recall/search operation. |
Action |
Check that the correct Configuration File is being used and that the Plan record is still defined. |
32 (0x0020) | |
Explanation |
Archive failed due to invalid/unsupported Extractor settings. |
Action |
Contact Software AG Support. |
33 (0x0021) | |
Explanation |
Archive failed due to invalid/unsupported Transfer settings. |
Action |
Contact Software AG Support. |
34 (0x0022) | |
Explanation |
Archive failed due to invalid/unsupported Accumulator settings. |
Action |
Contact Software AG Support. |
35 (0x0023) | |
Explanation |
Recall failed due to invalid or unsupported Extractor settings. |
Action |
Contact Software AG Support. |
36 (0x0024) | |
Explanation |
Recall failed due to invalid or unsupported Transfer settings. |
Action |
Contact Software AG Support. |
37 (0x0025) | |
Explanation |
Recall failed due to invalid or unsupported Accumulator settings. |
Action |
Contact Software AG Support. |
38 (0x0026) | |
Explanation |
Extractor terminated because the Accumulator is not active. |
Action |
Check the response and subcode for the Accumulator in Current or Completed Activities. |
39 (0x0027) | |
Explanation |
Accumulator timed-out waiting for the Extractor. |
Action |
Check the response and subcode for the Extractor in Current or Completed Activities. |
40 (0x0028) | |
Explanation |
Message protocol error/incompatibility. |
Action |
Contact Software AG Support. |
41 (0x0028) | |
Explanation |
Message protocol error/incompatibility. |
Action |
Contact Software AG Support. |
42 (0x0028) | |
Explanation |
Message protocol error/incompatibility. |
Action |
Contact Software AG Support. |
43 (0x0028) | |
Explanation |
Message protocol error/incompatibility. |
Action |
Contact Software AG Support. |
44 (0x0028) | |
Explanation |
Message protocol error/incompatibility. |
Action |
Contact Software AG Support. |
45 (0x002D) | |
Explanation |
Timeout waiting for lock on archive in Vault. |
Action |
Retry the operation and/or check for competing operations. |
46 (0x002E) | |
Explanation |
Version mismatch between Data Archiving for Adabas runtime and Vault contents. |
Action |
Contact Software AG Support. |
47 (0x002F) | |
Explanation |
Invalid/corrupt archive in Vault. |
Action |
Contact Software AG Support. |
48 (0x0030) | |
Explanation |
Archive in Vault contains data not supported by this version of the Data Archiving for Adabas runtime. |
Action |
Contact Software AG Support. |
49 (0x0031) | |
Explanation |
Archive size would exceed limit. |
Action |
Contact Software AG Support. |
50 (0x0032) | |
Explanation |
Invalid/unsupported Vault operation. |
Action |
Contact Software AG Support. |
51 (0x0033) | |
Explanation |
Archive does not exist in Vault. |
Action |
Contact Software AG Support. |
52 (0x0034) | |
Explanation |
Vault path does not exist. |
Action |
Check that the Vault Path defined for the Extractor, Accumulator and ADR Service computers is correct. |
53 (0x0035) | |
Explanation |
Access denied to Vault Path. |
Action |
Check that the Extractor, Accumulator and ADR Service computers have the correct filesystem permissions for the Vault Path. |
54 (0x0036) | |
Explanation |
Logical error manipulating Vault contents. |
Action |
Contact Software AG Support. |
55 (0x0037) | |
Explanation |
Extractor/Accumulator failed to load. |
Action |
Check the response and subcode for the Extractor/Accumulator in Pending, Current and Completed Activities. |
56 (0x0038) | |
Explanation |
Extractor/Accumulator failed to load. |
Action |
Contact Software AG Support. |
57 (0x0039) | |
Explanation |
Length of compressed record exceeds limit. |
Action |
Contact Software AG Support. |
58 (0x003A) | |
Explanation |
Length of decompressed record exceeds limit. |
Action |
Contact Software AG Support. |
59 (0x003B) | |
Explanation |
Cannot determine the default codepage for the system. |
Action |
Contact Software AG Support. |
60 (0x003C) | |
Explanation |
Invalid/unsupported codepage specified for archive or recall. |
Action |
Check that the codepage specified for in the Extractor/Accumulator settings in the Action or recall request. |
61 (0x003D) | |
Explanation |
‘Use default’ codepage specified for archive or recall and there is no default UES AMODE= setting for the database. |
Action |
Specify the codepage explicitly or configure the default AMODE= setting for the database. |
62 (0x003E) | |
Explanation |
No Search record found. |
Action |
Check that the correct Configuration File is being used and that the Search Record is still defined for the Action. |
63 (0x003F) | |
Explanation |
Cannot search archive because the data was not archived in compressed format. |
Action |
Contact Software AG support. |
64 (0x0040) | |
Explanation |
Invalid search (search buffer). |
Action |
Contact Software AG support. |
65 (0x0041) | |
Explanation |
Invalid search (value buffer). |
Action |
Contact Software AG support. |
66 (0x0041) | |
Explanation |
Value buffer for search could not be converted from the UI codepage to the codepage of the archived data. |
Action |
Contact Software AG support. |
67 (0x0042) | |
Explanation |
Validation failed to load. |
Action |
Contact Software AG support. |
68 (0x0043) | |
Explanation |
Internal error in Validation. |
Action |
Contact Software AG support. |
68 (0x0045) | |
Explanation |
License file is missing. |
Action |
Contact Software AG support. |
68 (0x0046) | |
Explanation |
License key is invalid. |
Action |
Contact Software AG support. |
68 (0x0047) | |
Explanation |
License has expired. |
Action |
Contact Software AG support. |
68 (0x0048) | |
Explanation |
License is for a different operating system. |
Action |
Contact Software AG support. |
68 (0x0049) | |
Explanation |
License is for a different product. |
Action |
Contact Software AG support. |
68 (0x004A) | |
Explanation |
License is for a different version. |
Action |
Contact Software AG support. |
112 (0x0070) | |
Explanation |
Archive, recall or search incomplete. |
Action |
Records have been skipped due to contention or errors. |
113 (0x0071) | |
Explanation |
Archive, recall or search failed. |
Action |
Check the response and subcode for the Extractor/Accumulator in Completed Activities. |
0000A001-FFFFA001 | |
Explanation |
TCP/IP error. The left-hand side of the subcode contains the operating system error code. |
0000A002-FFFFA002 | |
Explanation |
DNS error. The left-hand side of the subcode contains the operating system error code. |