STOP

Terminates the daemon in an orderly manner. The commands SHUTDOWN and ADAEND can also be used for the same purpose.

The daemon should not be stopped while there are jobs active.

DPARM Displays the runtime parameters for this execution of the daemon.
CAS DXCF

Displays message count information for cross-daemon XCF messages. The following counts are displayed in response messages CAS021I, CAS022I;

  • Msg-out: Total number of XCF messages sent by this daemon

  • Msg-in: Total number of XCF messages received by this daemon

  • Msg-rsp: Total number of message responses received

  • Msg-segs: Total number of message segments

  • Cq-Num: Number of queue elements in the Sysplex command queue. This will be equal to the command queue size specified, or defaulted, in the NXC parameter.

  • Cq-Hwm: Peak usage of the command queue. If this value is approaching the Cq-Num value it is advisable to increase the NXC value.

  • Cq-Full: Number of times a command queue full condition occurred. If greater than zero, increase the NXC value.

  • Cq-Post: Number of messages posted

  • RspPost: Number of responses posted

This command is not required during normal daemon operations, but its use may be requested by Software AG personnel for diagnostic purposes.

Note:
XCF message counts will only be displayed if the daemon is running in "standard multi-system" or "parallel sysplex" mode.

CAS DXCF RESET Displays message count information, as above, then resets all accumulated counters to zero.