Review the Report of Tape Creation that accompanies the release package before restoring the release data to disk. Information in this report supersedes the information in this documentation.
The installation tape contains the following datasets in the sequence indicated in the report:
Dataset | Contents |
---|---|
CORvrs.LIBR | Source, macro, object, and load modules |
CORvrs.INPL | SYSCOR INPL file |
CORvrs.ERRN | SYSCOR error messages file |
CORvrs.SYSF | Base configuration file |
where vrs in dataset names represents the version, revision, and system maintenance level of the product.
The steps needed for a successful installation are as follows:
Step | Description | Required | Job Name |
---|---|---|---|
1 | Restore the libraries from the installation tape | Yes | |
2 | Load (INPL) the SYSCOR application | Yes | CORI061.J |
3 | Load the configuration file and prepare SYSCOR | Yes | CORI050.J |
4 | Assemble the configuration module | Yes | CORI055.J |
5 | Add the Adabas System Coordinator to the Adabas clients | Yes |
CORI060.J, CORI080x.J (for Version 8 Adalnks) |
6 | Define the Adabas System Coordinator group and members | Required if a COR daemon is to be used | |
7 | Install the CICS node error program (optional) | Optional | |
8 | Create startup procedures for the Adabas System Coordinator daemon(s) | Required if a COR daemon is to be used | |
9 | Define runtime controls for Client jobs and TP systems | Yes |
The Adabas System Coordinator daemon must execute at a higher priority than the TP monitors and jobs it coordinates.
Corrections for the Adabas System Coordinator will be distributed as
zaps which are applied using the MSHP CORRECT facility. Before applying
corrections you must define Adabas System Coordinator to MSHP with the
MSHP ARCHIVE
command. Here is a sample job to do
this:
// JOB ARCHIVE ARCHIVE COORDINATOR // OPTION LOG // EXEC MSHP ARCHIVE CORvrs COMPRISES 9001-COR-00 RESOLVES ’SOFTWARE AG - SYSTEM CORDINATOR Vv.r’ ARCHIVE 9001-COR-00-vrs RESIDENCE PRODUCT=CORvrs - PRODUCTION=saglib.CORvrs - GENERATION=saglib.CORvrs /* /&
Following is the general Adabas System Coordinator installation procedure. The actual installation depends on your particular requirements and the specific contents of the release package provided by Software AG for your site. Information in the release package is intended for your system. If that information differs from the information in this section, use the release package information or contact Software AG technical support for assistance.
Use the following sample JCS to restore the Adabas System Coordinator library. Modify the following variables to reflect the standards at your site:
Variable | Is the... |
---|---|
cuu | tape unit number |
tttttt | volume serial number of the installation tape |
vrs | version, revision, and system maintenance level |
xx | file spacing information; see the Report of Tape Creation |
* $$ JOB JNM=LIBREST,CLASS=O,DISP=D * $$ LST CLASS=A,DISP=H // JOB LIBREST // ASSGN SYS006,cuu,VOL=tttttt // ASSGN SYS005,IGN // MTC REW,SYS006 // MTC FSF,SYS006,xx // EXEC LIBR RESTORE S=SAGLIB.CORvrs:SAGLIB.CORvrs – TAPE=SYS006 TL=tttttt LIST=Y /* // MTC REW,SYS006 /& * $$ EOJ
Note:
The library contains the kernel phases CORKRN and CASKRN, which must
be available to the various databases, TP monitors, and batch jobs that will
use Adabas System Coordinator.
Use sample job CORI061.J to load the SYSCOR online administration and error messages file into Natural.
System Coordinator and related products operate according to definitions contained in the configuration file. You must allocate a new Adabas file for the Version 8.1 configuration file and load CORvrl.SYSF into it using the supplied sample job CORI050.J. The online services will guide you through the steps required to make the new file ready for use, including conversion from previous versions of System Coordinator.
To load the configuration file
Load the Adabas System Coordinator configuration file from the distribution tape using the standard Adabas load utility ADALOD. Use sample job CORI050.J. If you are using an alternate configuration file you need to run this job to initialize both files.
If Natural Security is installed, define the libraries SYSCOR and SYSMPvrs (where vrs is the version you are installing, for example 812) and protect as required. You may define MENU as the startup transaction for SYSCOR. DO NOT define a startup transaction for SYSMPvrs.
Use the following parameter to define the Natural session where SYSCOR is to be used:
LFILE=(152,dbid,fnr<,passw><,ciph>)
where dbid and fnr define the primary Adabas System Coordinator file.
Alternatively, assemble the Natural parameter module with:
NTFILE
,ID=152,DBID=dbid,FNR=fnr
To convert a previous version’s definitions to version 8 format
Logon to library SYSCOR and enter MENU
.
SYSCOR will detect that the configuration file is new and will guide you
through the steps required to copy and convert the definitions from a previous
version.
Repeat this procedure for each configuration file to be converted. The procedure only needs to be done once for each configuration file, regardless of how many products use it. Other products may have additional conversion requirements.
Adabas System Coordinator parameters are located in the configuration file. At job start, the Adabas System Coordinator needs to know the location of this file. This information is kept in the configuration module.
Create the configuration module by assembling the CORMCFG parameters defining the SVC, database, and file number of the Adabas System Coordinator configuration file.
Keyword | Description |
---|---|
SVC= | Your installation’s Adabas SVC number |
DBID= | Database number for the System Coordinator configuration file |
FNR= | File number for the System Coordinator configuration file |
ADBID= | Database number for the alternate System Coordinator configuration file. If not specified, an alternate file will not be used. |
AFNR= | File number for the alternate System Coordinator configuration file. If not specified, an alternate file will not be used. |
SF148=WAIT | Use this keyword if you want client jobs to
wait when the specified configuration file is not active. If you omit this
keyword, the RETRY= setting takes effect (see below).
|
CRITICAL= |
Use this keyword if you want System Coordinator to check for availability and correct functioning of supported add-on products. You may specify one or more of the following, separated by commas:
If any critical product is not functioning correctly, all Adabas requests will be rejected with response code 101, subcode 59. |
DMWAIT= | Specifies a maximum time (in minutes) that the System Coordinator daemon will wait for the configuration file database to be activated. If not specified, the daemon will wait indefinitely. The default is 60. |
RETRY= | RETRY specifies the frequency (number of Adabas
calls issued in this client job) at which System Coordinator in the client job
will retry access to its configuration file after a response 148. The default
is 1000. Client services provided by System Coordinator and its supported
add-on products are not available until the configuration file becomes active.
RETRY only takes effect if SF148=WAIT has not been
specified.
|
Name the resulting load module CORCFG (this is required).
Use sample job CORI055.J.
Link the appropriate Adabas System Coordinator client component with your Adabas link modules.
The stub modules are called CORS1n where n is a subsystem suffix.
The modified link module is for use by client jobs only.
Adabas System Coordinator is compatible with Version 8 and Version 7
link modules. When using Version 8 link modules you must re-assemble the
LNKGBLS table, specifying the parameter COR=YES
in the
LGBLSET macro.
The load library contains the kernel modules CORKRN and CASKRN, which must also be available to all client jobs that will use the Adabas System Coordinator.
If you are migrating from a previous version, you must ensure that you use the new load library modules. It is not possible to use the Version 8 link module stub with Coordinator modules from a previous version.
Job Type | Stub Module | Sample Job |
---|---|---|
Batch | CORS11 | CORI060.J (Version 8 link), CORI0607.J (Version 7 Link) |
Com-plete | CORS12 | CORI080C.J (Version 8 link), CORI070C.J (Version 7 Link) |
CICS Command Level | CORS13 | CORI080B.J (Version 8 link), CORI070B.J (Version
7 Link)
Note: Note: |
Triggers and Stored Procedures | CORS18 | CORI080S.J (Version 8 link), CORI070S.J (Version 7 Link) |
Define a System Coordinator group and member(s). This is required if you intend to use:
Adabas Fastpath
clustered applications with dynamic transaction routing.
Job parameters for each product also contain settings that are relevant to the operation of the Adabas System Coordinator. For more information, see SYSCOR Administration.
The node error program CORNEP is used by sites running CICS command-level applications. It is not an essential component, but it does improve efficiency when reclaiming memory after user sessions terminate.
CORNEP is started (with Transaction ID ANEP) from the real CICS node error program DFHZNEP. The source for DFHZNEP is supplied on the installation tape and can be installed without change. If you have your own DFHZNEP program already installed, you will need to implement the code for starting CORNEP into your own DFHZNEP.
Following are the required CICS resource definition parameters for CORNEP:
Language: Assembler
RESident: No
Datalocation: Any
EXECKey: User
Note:
To use CORNEP, assemble your Adabas link module with
PARMTYP=ALL
on the ADAGSET (Version 7 link module) or
LGBLSET (Version 8 link module) macro.
Note:
CORNEP must be called only from DFHZNEP.
The following is a job example for running a Adabas System Coordinator daemon:
* ££ JOB JNM=SYSCO1,CLASS=5,DISP=D * ££ LST CLASS=A,DISP=D * ******************************************************* // JOB SYSCO1 * ******************************************************* * JOB TO RUN SYSCO: THE SYSTEM COORDINATOR * * ******************************************************* // OPTION NOSYSDUMP // LIBDEF PHASE,SEARCH=(SAGLIB.CORvrs,SAGLIB.ADAvrs) // EXEC SYSCO,SIZE=AUTO PRODUCT=CAS FORCE=NO /* * *********** JOB END SYSC01 /& * ££ EOJ
If SYSCO terminates abnormally, it may be necessary to specify
FORCE=YES
on restart.
System Coordinator can be installed for all client jobs, but will be inactive until runtime controls are defined. Controls are defined in the SYSCOR Natural application, using the Maintenance menu. Refer to the Online Services section for further information.
Alternatively, you can delay this task until you have installed the appropriate add-on product(s). You may then use any of the supplied maintenance applications (SYSAFP, SYSAVI or SYSATM).