The ACCHECK function checks the address converter of a specified database file. In addition, it automatically checks the secondary address converter if the file contains spanned records.

graphics/util_adaick_accheck.png

This document covers the following topics:


Essential Parameter

FILE: File to be Checked

The file to be checked. A file number is required the first time you execute ADAICK.

If FILE is omitted on subsequent executions, the last file used by ADAICK is checked.

Top of page

Optional Parameters

NOOPEN: Prevent Open Synchronization

When starting, ADAICK normally performs a utility open call to the nucleus to assure that no blocks of the affected file or files are still in the nucleus buffer pool. However, this also locks the file for other users. Specifying NOOPEN prevents ADAICK from issuing the open call.

NOUSERABEND: Termination without Abend

When an error is encountered while the function is running, the utility prints an error message and terminates with user abend 34 (with a dump) or user abend 35 (without a dump).

If NOUSERABEND is specified, the utility will not abend after printing the error message. Instead, the message "utility TERMINATED DUE TO ERROR CONDITION" is displayed and the utility terminates with condition code 20.

Top of page

Sample Output

The following sample of the output produced from an ADAICK ACCHECK run is for an Adabas 8 database that makes use of spanned records, and thus includes a secondary address converter.

FILE 002 AC CHECK                                                           
FILE 002                   AC                               LOW            HIGH            NR OF                            THRU   
FILE 002                   ISN-ISN                        RABN          DS RABN     DS RABN        RECORDS ISN (DEC)
FILE 002                   00000001-0000034F 000000E1      000001D9 0000023C            25       847      
FILE 002                   00003850-00003B9F 000000F2      00000000 00000000            25       15,263   
FILE 002 AC2 CHECK                                                           
FILE 002                                         AC2         LOW AC2   HIGH AC2            NR OF      THRU     
FILE 002      AC2 ISN-ISN               RABN       DS RABN     DS RABN            RECORDS AC2 ISN  
FILE 002      00000001-0000034F 000000F3 000001DA 0000023F           100           848      