This section lists and describes all messages that can occur when operating the Adabas Delta Save Facility.
For messages displayed on the operator console, each line begins with the message number followed by the database ID. For messages returned in the job protocol, the message number occurs only once and the database ID is not displayed.
The following message groups are described:
Nucleus-Related Console Messages (DSF001 - DSF029, DSF02A-D)
Utility-Related Job Protocol Messages for ADARES and ADASAV (DSF030 - DSF099)
This section lists and describes all messages displayed by the Delta Save Facility during an Adabas nucleus session. These messages all appear on the operator console.
DSF001 | DSF002 | DSF003 | DSF004 | DSF005 | DSF006 | DSF007 | DSF008 | DSF011 | DSF012 | DSF013 | DSF014 | DSF015 | DSF016 | DSF017 | DSF018 | DSF019 | DSF020 | DSF021 | DSF022 | DSF023 | DSF024 | DSF025 | DSF026 | DSF027 | DSF028 | DSF029 | DSF02A | DSF02C | DSF02D
DSF001 | Running with Delta Save Facility |
Explanation |
The nucleus has been started with ADARUN parameter DSF=YES. Delta Save functions can be performed in this nucleus session. |
DSF002 | The DSF logging area is not installed |
Explanation |
This is a Delta Save Facility status message. Delta save operations require a Delta Save logging (DLOG) area, which must be created. |
Action |
To run with Delta Save, use the Adabas Online System Install DSF function to define the logging area. |
DSF003 | DSF logging is disabled |
Explanation |
This is a Delta Save Facility status message. Delta save operations are not possible. |
DSF004 | DSF logging is enabled |
Explanation |
This is a Delta Save Facility status message. Delta save operations are possible in this status. |
DSF005 | count DLOG area blocks out of total used (nn%) Pending DLOG area overflow; perform Delta Save operation |
Explanation |
This message indicates how much of the Delta Save logging (DLOG) area is being used. The second line of the message is only printed if the DLOG area usage is 90 percent or more; that is, nearly full. If the area overflows, Delta Save operations will no longer be possible. |
Action |
If DLOG area overflow is pending, perform a Delta Save operation before the area overflows. |
DSF006 | DSF logging area not initialized Reinstall the DLOG area |
Explanation |
Initialization of the Delta Save logging (DLOG) area was interrupted. The DLOG area must be installed again. |
Action |
Remove the DLOG area and install it again. |
DSF007 | DSF logging area not initialized DSF logging not enabled at end of save |
Explanation |
Initialization of the Delta Save logging (DLOG) area was interrupted. An online full save operation was completed but Delta Save logging was not enabled at the end of the save. Delta save operations are still not possible. |
Action |
Remove the DLOG area and install it again. Perform another full save operation. |
DSF008 | I/Os initiated by Delta Save Facility: read-count reads, write-count writes |
Explanation |
This message, which is printed during shutdown of the Adabas nucleus, indicates the number of I/O operations initiated by Delta Save during the current nucleus session. |
DSF011 | Online full save operation completed |
Explanation |
Unless this message is displayed, an online full save operation with the Delta Save Facility is not successful, even though ADASAV may have already closed the output save data set. |
Action |
The Delta Save logging area is reset. If Delta Save logging was disabled, it will be enabled. |
DSF012 | Online Delta Save operation completed |
Explanation |
Unless this message is displayed, an online Delta Save operation is not successful, even though ADASAV may have already closed the output save data set. |
Action |
The Delta Save logging area is reset. |
DSF013 | Delta Save ID = fsnum / dsnum / date-time |
Explanation |
This message follows messages DSF005, DSF011, or DSF012. It displays the Delta Save identification of the most recent completed full or Delta Save operation. fsnum is the full save number, and dsnum is the number of the Delta Save operation. |
DSF014 | DSF loggin has been enabled |
Explanation |
This message follows messages DSF011 and DSF013 if Delta Save logging was previously disabled. It was enabled at the end of the operation. Delta save operations are now possible. |
DSF015 | Disable DSF requested by AOS command |
Explanation |
A Disable DSF command was issued by Adabas Online System. |
Action |
Delta Save logging will be disabled. |
DSF016 | DSF logging has been disabled |
Explanation |
The reason for this follows from a preceding message. Delta save operations are no longer possible. |
Action |
Perform a full save operation before retrying a Delta Save operation. |
DSF017 | Initializing the DSF logging area |
Explanation |
An Install DSF or Change DLOG Area command has been issued through Adabas Online System. |
Action |
The Delta Save logging area is now being initialized. Message DSF018 indicates that initialization is complete. |
DSF018 | The DSF logging area has been {installed | changed} |
Explanation |
An Install DSF or Change DLOG Area command was completed. |
DSF019 | The DSF logging area has been removed |
Explanation |
A Remove DSF command was performed, or the nucleus was started with DSF=NO and has removed the Delta Save logging area. |
DSF020 | DSF logging area overflow |
Explanation |
The volume of changes made to the database exceeded the capacity of the Delta Save logging (DLOG) area. The DLOG area is full. No more Delta Save operations are possible. Delta Save logging will be disabled. |
Action |
Perform a full save operation before retrying a Delta Save operation. Increase the DLOG area or the frequency of Delta Save operations in order to avoid future DLOG area overflow. |
DSF021 | I/O error {reading | writing } DLOG RABN rabn |
Explanation |
An I/O error occurred within the Delta Save logging (DLOG) area on the specified Associator RABN. If Delta Save logging is enabled, it will be disabled. |
Action |
Determine the cause of the I/O error and eliminate it. Remove the DLOG area and install it again. |
DSF022 | Fatal I/O error {reading | writing} DLOG header RABN rabn | ||
Explanation |
An I/O error occurred on the first block (the specified RABN) of the Delta Save logging (DLOG) area.
The Delta Save Facility terminates the nucleus abnormally. |
||
Action |
Determine the cause of the I/O error and eliminate it. Remove the DLOG area and install it again. |
DSF023 | DLOG area header RABN rabn bad ( # rr ) Reinstall DLOG area or DLOG area detail RABN rabn bad ( # rr at +xxxx Reinstall DLOG area |
Explanation |
An inconsistency was detected in the specified block (rabn) of the Delta Save logging (DLOG) area. rabn is the Associator block number, rr is an internal reason code, xxxx the offset within the block where the error appeared. If Delta Save logging is enabled, it will be disabled. |
Action |
Determine the cause of the problem; consult your Software AG technical support representative if necessary. Remove the DLOG area and install it again. |
DSF024 | Inconsistent Delta Save ID in DLOG RABN rabn |
Explanation |
An inconsistency was detected in the specified block (rabn) of the Delta Save logging (DLOG) area. rabn is the Associator block number. If Delta Save logging is enabled, it will be disabled. |
Action |
Determine the cause of the problem; consult your Software AG technical support representative if necessary. Remove the DLOG area and install it again. |
DSF025 | DSF logging not disabled because READONLY=YES |
Explanation |
An attempt to disable Delta Save logging failed because the nucleus was started with READONLY=YES. Another attempt will be made to disable Delta Save logging in the next nucleus session. |
Action |
Shut down the nucleus and restart it with READONLY=NO so that Delta Save logging can be disabled. |
DSF026 | Unlogged RABN(s) detected: type start-rabn end-rabn |
Explanation |
An internal cross-check detected that database blocks were written that had not been logged by Delta Save. The type (Asso/Data) and range of RABNs written are displayed. Delta Save logging will be disabled. |
Action |
This is a serious problem. Contact your Software AG technical support representative. Perform a full save operation before retrying a Delta Save operation. |
DSF027 | Insufficient memory (trying to allocate count bytes) |
Explanation |
The Delta Save Facility was not able to obtain sufficient memory for its operation. The number of bytes of memory specified by count were requested. The start of the nucleus session is ended. |
Action |
Increase the region/partition of the nucleus job/task or decrease the memory requirements derived from the nucleus parameters. |
DSF028 | DSF version mismatch; reinstall DLOG area |
Explanation |
The version of the Delta Save Facility software and the version of the Delta Save logging (DLOG) area are different and incompatible. If Delta Save logging is enabled, it will be disabled. |
Action |
Remove the DLOG area and install it again. |
DSF028 | Converting from DSF xx to DSF yy |
Explanation |
The format of the Delta Save logging (DLOG) area is converting from version xx to version yy. This occurs during conversion of an older Adabas version to a newer one. Depending on the versions of the Delta Save Facility (that is, xx and yy), Delta Save logging may be disabled if it is enabled. |
Action |
If Delta Save logging is disabled, perform a full save operation before retrying a new Delta Save operation. |
DSF029 | DSF internal error at ADADSFN + offset (reason-code) R0-R3 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx R4-R7 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx R8-R11 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx R12-R15 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx |
Explanation |
An internal error occurred at the specified offset in module ADADSFN. reason-code is an internal reason code. The register settings at the time of the error are shown. If Delta Save logging is enabled, it will be disabled. |
Action |
Consult with your Software AG technical support representative to determine the cause of the problem. Perform a full save operation before retrying a Delta Save operation. |
DSF02A | Percentage error in DSF user exit; nn% is used |
Explanation |
The DSF user exit returned an invalid threshold value (percentage of DLOG area usage at or above which Adabas is to call the exit). Adabas calls the DSF user exit when the usage of the DLOG area is nn% or more. |
DSF02C | Current DLOG block not found in cache, read from disk |
Explanation |
The DLOG block currently referenced is not in the coupling facility cache structure and must be read anew from the disk data sets. |
DSF02C | Current DLOG block written to cache |
Explanation |
The DLOG block currently referenced is already held in the coupling facility cache structure. |
DSF02D | Write of current DLOG block to cache failed |
Explanation |
An attempt to write the DLOG block currently referenced from a disk data set to the coupling facility cache structure failed. Probably, the cache structure is full. |
Action |
Enlarge the size of the cache. |
The messages in this section are displayed by the Delta Save Facility during ADARES or ADASAV utility execution. They can occur in Adabas utility operations, either as direct utility messages or as the result of utility-related nucleus operation.
Most messages appear in the utility job protocol (DD/DRUCK or SYSLST); others appear in the ADARUN protocol (DD/PRINT, SYS009 or SYSOUT). A few messages appear in the utility job protocol as well as on the operator console; this is indicated in the explanation of these messages.
Note:
Messages begin with the relevant database ID when they are written to
the operator console.
DSF030 | DSF031 | DSF032 | DSF033 | DSF034 | DSF036 | DSF037 | DSF038 | DSF039 | DSF040 | DSF041 | DSF042 | DSF043 | DSF044 | DSF045 | DSF046 | DSF047 | DSF048 | DSF049 | DSF050 | DSF051 | DSF052 | DSF053 | DSF054 | DSF055 | DSF057 | DSF058 | DSF059 | DSF060 | DSF061 | DSF062 | DSF063 | DSF065 | DSF066 | DSF067 | DSF068 | DSF070 | DSF071 | DSF072 | DSF074 | DSF075 | DSF076 | DSF079 | DSF080 | DSF081 | DSF082 | DSF083 | DSF084 | DSF085 | DSF086 | DSF087 | DSF088 | DSF089 | DSF090 | DSF091 | DSF092 | DSF093 | DSF094 | DSF095 | DSF096 | DSF097 | DSF098 | DSF099
DSF030 | DSIM dataset omitted from PLCOPY processing |
Explanation |
The ADARUN parameter DSF=YES was specified for a PLCOPY execution but no Delta Save images (DSIM) data set was supplied in the job control. No system action occurs; no online save information is extracted from the protection log. |
Action |
If Delta Save online save and merge operations are to be performed, specify a DSIM data set for the PLCOPY executions. |
DSF031 | SYN1 checkpoint encountered on protection log PLOGNUM=plog-number BLOCKNUM=rabn |
Explanation |
A SYN1 checkpoint (online save start) was found on the protection log. The protection log number is plog-number, the SYN1 block number is rabn. The Delta Save Facility starts extracting online save information from the protection log and writing it to the Delta Save images (DSIM) data set. |
DSF032 | SYN2 checkpoint encountered on protection log PLOGNUM=plog-number BLOCKNUM=rabn |
Explanation |
A SYN2 checkpoint (online save end) was found on the protection log. The protection log number is plog-number, the SYN2 block number is rabn. The Delta Save Facility stops extracting online save information from the protection log. The Delta Save images (DSIM) data set is marked ready for merge. |
DSF033 | SYN1 checkpoint ignored on protection log. PLOG and block numbers different from parameters checkpoint found has PLOGNUM=plog-number, SYN1=block-number |
Explanation |
A SYN1 checkpoint (online save start) was found on the protection log. The protection log number is plog-number, the SYN1 block number is block-number. These values are different from the PLOGNUM and SYN1 parameters specified for the COPY function. The Delta Save Facility does not start extracting online save information from the protection log. The SYN1 checkpoint is ignored. |
DSF033 | SYN1 checkpoint ignored on protection log DSIM dataset already completed |
Explanation |
A SYN1 checkpoint (online save start) was found on the protection log but the Delta Save images (DSIM) data set is by now ready for merge. The SYN1 checkpoint is ignored. |
DSF033 | SYN1 checkpoint ignored on protection log DSIM dataset status incorrect: status-code |
Explanation |
A SYN1 checkpoint (online save start) was found on the protection log but the Delta Save images (DSIM) data set is not in a correct status. The current DSIM status status-code is shown. The SYN1 checkpoint is ignored. |
Action |
Rebuild the DSIM data set using the ADARES COPY function. |
DSF033 | SYN1 checkpoint ignored on protection log online save operation started afterwards |
Explanation |
A SYN1 checkpoint (online save start) was found on the protection log but was written before the start of the online save operation associated with the DSIM data set. Therefore, the checkpoint does not indicate the start of the online save operation for which information is to be extracted from the protection log. The SYN1 checkpoint is ignored. |
Action |
None. If there is only one SYN1 checkpoint on the protection log to be copied and the message cannot be otherwise explained, check whether the Adabas nucleus and the ADASAV utility that is executing the online save operation were running on different machines or on different divisions of the same machine. If so, ensure that the local times of these two machines or divisions are accurately synchronized. |
DSF034 | SYN2 checkpoint ignored on protection log DSIM dataset status incorrect: status-code |
Explanation |
A SYN2 checkpoint (online save start) was found on the protection log but the previous SYN1 checkpoint was ignored because of the incorrect status of the Delta Save images (DSIM) data set. The current DSIM status status-code is shown. See the corresponding DSF033 message. The SYN2 checkpoint is ignored. |
Action |
Rebuild the DSIM data set using the ADARES COPY function. |
DSF036 | DSIM dataset opened with status: status |
Explanation |
(printed on the ADARUN protocol) The Delta Save images (DSIM) data set has been opened. Its current status is shown. |
DSF037 | DSIM dataset status changed to: status |
Explanation |
(printed on the ADARUN protocol) The Delta Save images (DSIM) data set status has been changed to the new one shown. |
DSF038 | DSIM dataset closed with status: status |
Explanation |
(printed on the ADARUN protocol) The Delta Save images (DSIM) data set has been closed. Its current status is shown. |
DSF039 | DSIM dataset completed DSIM dataset statistics: nn% full asso-count ASSO block images written data-count DATA block images written ac-count new AC blocks recorded |
Explanation |
The Delta Save images (DSIM) data set has been completed and marked ready for merge. Statistics displayed include
|
DSF040 | [dbid] Waiting for DSIM dataset |
Explanation |
This message, which is printed on the operator console with a dbid and on the ADARUN protocol without a dbid, indicates that the Delta Save images (DSIM) data set is not yet ready for merge. The DSIMWAIT parameter has been specified to wait for the completion of the DSIM data set. The Delta Save Facility waits until the DSIM data set is ready for merge, or until the maximum wait time (DSIMWAIT) has been exceeded. |
DSF041 | DSF logging area nn% full at begin of save |
Explanation |
This message indicates how much of the Delta Save logging (DLOG) area is already being used at the beginning of a Delta Save operation. |
DSF042 | [dbid] {offline | online} {full | delta} save operation completed DSID= fsnum dsnum date-time |
Explanation |
The specified type of save operation was completed successfully. The ID of the Delta Save operation (DSID) is displayed: fsnum and dsnum are the numbers of the full and Delta Save operation, respectively. For an offline save operation, this message is also written to the operator console with a dbid. For an online save, the Adabas nucleus writes equivalent information in the DSF011-DSF013 messages. For an offline save operation, the Delta Save logging (DLOG) area is reset. For a full save operation, if Delta Save logging was disabled, it will be enabled
|
DSF043 | [dbid] DSF logging enabled by offline full save |
Explanation |
This message occurs following message DSF042. Delta Save operations are now possible. Unless this message is displayed, an offline full save operation with the Delta Save Facility is not successful, even though ADASAV may have already closed the output save data set. This message is also written to the operator console with a dbid. |
DSF044 | Delta Save statistics: asso-count ASSO blocks to be saved data-count DATA blocks to be saved |
Explanation |
(printed at the beginning of a Delta Save operation) The number of Associator and Data Storage blocks to be saved. |
DSF045 | Input {offline | online} {full | data} save tape opened DSID= fsnum lowdsnum-hidsnum date-time |
Explanation |
In a MERGE or RESTORE DELTA operation, an input save data set with the stated Delta Save identification was opened. fsnum is the full save number; lowdsnum the low Delta Save number, and hidsnum the high Delta Save number of the save data set. |
DSF045 | Input {offline | online} Delta Save tape opened (concatenated) DSID= fsnum lowdsnum-hidsnum date-time |
Explanation |
In a MERGE or RESTORE DELTA operation, an input Delta Save data set with the stated Delta Save identification was opened. The Delta Save data set was concatenated to another Delta Save data set. fsnum is the full save number; lowdsnum the low Delta Save number, and hidsnum the high Delta Save number of the save data set. |
DSF045 | Input online Delta Save tape opened (unloaded DSIM) DSID= fsnum / dsnum / date-time |
Explanation |
In a MERGE or RESTORE DELTA operation, an input online Delta Save data set with the stated Delta Save identification was opened. The Delta Save data set is an unloaded DSIM data set. fsnum is the full save number; dsnum the Delta Save number of the save data set. If the originating DSIM data set was (re)built from the PLOG using the ADARES COPY function, the DSID is unknown and shown as zeros. |
DSF046 | Restored delta without full save input DSID of database = fsnum hidsnum date-time |
Explanation |
In a delta restore operation without full save input the database has the stated Delta Save identification. The associated full and Delta Save data sets were restored previously. The value fsnum denotes the full save number, hidsnum is the highest Delta Save number of the save data sets already restored. |
DSF047 | [dbid] Output offline {full | delta} save tape completed DSID= fsnum lowdsnum-hidsnum date-time |
Explanation |
In a MERGE operation, the indicated output save data set has been completed. Its Delta Save identification is shown. fsnum denotes the full save number. lowdsnum is the low Delta Save number and hidsnum is the high Delta Save number. This message is also written to the operator console with a dbid. |
DSF047 | [dbid] Output online Delta Save tape completed (unloaded DSIM) DSID= fsnum dsnum date-time |
Explanation |
In a MERGE operation, an unloaded DSIM Delta Save data set with the Delta Save identification shown has been written. fsnum denotes the full save number; dsnum is the Delta Save number. If the originating DSIM data set was (re)built from the PLOG using the ADARES COPY function, the DSID is unknown and shown as zeros. This message is also written to the operator console with a dbid. |
DSF048 | [dbid] Restore of {(merged) full | (concatenated) delta } save tape [ (s) ] completed restored Delta Save ID= fsnum lowdsnum-hidsnum / date-time |
Explanation |
A phase of a delta restore operation has been completed. One or more save tapes have been restored. Their combined Delta Save identification is shown. A subsequent delta restore operation without full save input may begin with the Delta Save data set that has the next higher Delta Save identification. fsnum is the full save number. The value lowdsnum is the low Delta Save number, and hidsnum is the high Delta Save number. This message is also written to the operator console with a dbid. |
DSF049 | DSIM dataset statistics: asso-count ASSO blocks present data-count DATA blocks present |
Explanation |
This message is printed when the Delta Save images (DSIM) data set is examined and matches one of the online save input data sets. It is also printed when the DSIM data set is to be unloaded. The DSIM data set contains asso-count different Associator blocks and data-count different Data blocks to take part in the operation. |
DSF050 | DSF logging are not installed |
Explanation |
Without a Delta Save logging (DLOG) area installed and Delta Save logging enabled, it is not possible to perform Delta Save operations. The Delta Save operation is abnormally terminated. |
Action |
Use Adabas Online System to install a DLOG area and perform a full save operation to enable Delta Save logging. |
DSF051 | DSF logging not enabled |
Explanation |
Delta Save logging must be enabled before Delta Save operations are possible. The attempted Delta Save operation is abnormally terminated. |
Action |
Perform a full save operation to enable Delta Save logging. |
DSF052 | DSIM dataset omitted from online save operation |
Explanation |
When running with Delta Save (ADARUN parameter DSF=YES is specified), a Delta Save images (DSIM) data set must be provided for an online full or Delta Save operation. The online save operation is abnormally terminated. |
Action |
Supply a DSIM data set for the online save operation or perform the save operation offline. |
DSF053 | DSIM dataset not ready for save |
Explanation |
The Delta Save images (DSIM) data set must be "not in use" to be eligible for a Delta Save Facility online save operation. The current status of the DSIM data set is different, as shown. The online save operation is abnormally terminated. |
Action |
Determine whether the DSIM data set is required for merging a previously created online save tape. If not, reset the DSIM data set (using ADAFRM function DSIMRESET) and rerun the save operation. |
DSF054 | Online save failed at ET synchronization |
Explanation |
Execution of ET-synchronization at the end of the online save operation was not successful. The Delta Save logging (DLOG) area was not reset. Delta Save logging remains disabled if it was disabled before, or enabled if it was enabled before. A subsequent ADASAV error message indicates the nucleus response code for the failed ET-synchronization. Although it has already been closed, the created save data set must not be used for later merge or restore operations. The online save operation is abnormally terminated. |
Action |
Eliminate the cause of the error and rerun the online save operation. |
DSF055 | Online save successful in spite of nucleus response |
Explanation |
Execution of ET-synchronization at the end of the online save operation was successful. The Delta Save logging (DLOG) area was reset. Afterwards, an error occurred and caused a nucleus response code to be returned to ADASAV. A subsequent ADASAV error message indicates the response code returned by the nucleus. If Delta Save logging was disabled before, it has been enabled. ADASAV prints an error message but continues operation. When terminating normally, it will set condition code 4. |
Action |
The created save tape is valid and may not be dropped if Delta Save operations are to follow later on. Otherwise the succeeding Delta Save data sets cannot be merged and/or restored. |
DSF057 | Unloading DSIM dataset |
Explanation |
Only the DSIM data set has been specified for processing. No full or Delta Save input data set has been supplied. |
Action |
ADASAV unloads the DSIM data set to the sequential output save data set and frees the DSIM data set for the next online save operation. |
DSF058 | [dbid] Full save tape restored-DSF logging enabled restored Delta Save ID = fsnum / lowdsnum - hidsnum / date-time |
Explanation |
A full save tape created by the Delta Save Facility was restored. The Delta Save identification of the restored database is shown. fsnum is the full save number; lowdsnum is the low deta save number; and hidsnum is the high Delta Save number of the save data sets restored. This message is also written to the operator console with a dbid. Delta Save logging was enabled in the restored database. |
Action |
The next save operation can be a Delta Save. Its result can be merged with the full save that was input to the restore operation. |
DSF059 | Removing DSF logging area (DSF=NO specified) |
Explanation |
A full save created by the Delta Save Facility is to be restored but the ADARUN parameter DSF=NO has been specified. The Delta Save logging (DLOG) area will be removed. The restore operation continues normally. |
Action |
None required. If the restored database is to be run with the Delta Save Facility, install the DLOG area again. |
DSF060 | Insufficient inputs for merge or restore delta |
Explanation |
The input data set requirements for
The MERGE or RESTORE DELTA operation is abnormally terminated. |
Action |
Supply suitable input data sets. If the function is RESTORE DELTA, rerun the job with RESTORE instead of RESTORE DELTA. |
DSF061 | Input save tape coming from wrong database |
Explanation |
In a merge or delta restore operation, the database ID of an input save data set is different from that specified in the ADARUN DBID parameter. Both database IDs are shown. The merge or delta restore operation is abnormally terminated. |
Action |
Supply the proper save tape or correct the ADARUN DBID parameter. |
DSF062 | Invalid specification of input datasets in JCL/JCS |
Explanation |
In a merge or delta restore operation, the input save data sets are not specified correctly:
The merge or delta restore operation is abnormally terminated. The DD-name/link-name of the offending input data set is displayed. |
Action |
Supply the proper input save tapes and rerun the job. |
DSF063 | DSIM dataset missing or in wrong status |
Explanation |
The original or unloaded Delta Save images (DSIM) data set is required for processing an online save data set in a MERGE or RESTORE DELTA operation, but it either
The MERGE or RESTORE DELTA operation is abnormally terminated. |
Action |
Provide the correct DSIM data set; rebuild it if necessary. Rerun the job. |
DSF065 | Input full and Delta Save tapes not fitting together |
Explanation |
The specified input full and Delta Save data sets do not cover a continuous sequence of save operations. Their Delta Save identifications (DSIDs) do not match, because one or more of the following is true:
For a RESTORE DELTA operation without full save input, the DSID of the database takes part in this matching of DSIDs. The DSIDs matched have been displayed in previous messages. The MERGE or RESTORE DELTA operation is abnormally terminated. |
Action |
Provide the correct input save data sets in the correct sequence. Rerun the job. |
DSF066 | DSIM dataset does not match online save tape |
Explanation |
A provided original or unloaded Delta Save images (DSIM) data set is not the one associated with the specified input online save data set. It does not contain the block images written during the online save operation that created the save data set. The DSIM data set's full save number, Delta Save number, and database ID are shown. Further, the protection log number and protection log block number of the save operation's SYN1 checkpoint are displayed for both the DSIM data set and the online save data set. For associated online save and DSIM data sets, these SYN1-related numbers must be identical. The MERGE or RESTORE operation is abnormally terminated. |
Action |
Provide the right DSIM data set and/or input save data sets. Rerun the job. |
DSF067 | Mismatching merge/restore pattern |
Explanation |
The delta merge/restore pattern specified in the PATTERN parameter does not match the input full and Delta Save data sets supplied. The delta merge or delta restore operation is abnormally terminated. |
Action |
Check and correct the PATTERN parameter and the job control statements. Rerun the job. |
DSF068 | Incalid save dataset concatentation |
Explanation |
Another data set was concatenated to one of the input data sets (the DD-name/link-name of the input data set is shown). Input save data set concatenation is allowed only if
The MERGE or RESTORE DELTA operation is abnormally terminated. |
Action |
Correct the specification of input data sets and rerun the job. |
DSF070 | DSIM dataset smaller than specified |
Explanation |
An I/O error occurred when Delta Save Facility tried to read the last block of the Delta Save images (DSIM) data set. It is probably smaller than specified. Building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Correct the DSIMSIZE parameter or supply a correct DSIM data set. If the function was PLCOPY, rebuild the DSIM data set using the COPY function. Otherwise, rerun the COPY function. |
DSF071 | Protection log and DSIM dataset do not match |
Explanation |
The protection log and the Delta Save images (DSIM) data set belong to different databases. The two database IDs are shown. No online save information will be extracted from the protection log during this ADARES execution. Building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Provide the correct protection log or rebuild the DSIM data set. If the function was PLCOPY, rebuild the DSIM data set using the COPY function. Otherwise rerun the COPY function. |
DSF072 | Cannot locate SYN1 checkpoint on protection log |
Explanation |
The specified SYN1 checkpoint on the protection log was not found. The specified SYN1 position and the current position on the protection log are shown. No online save information will be extracted from the protection log during this ADARES execution. Building the DSIM data set is discontinued. The COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified, a subsequent ADARES error abnormally terminates the function. |
Action |
Supply matching protection log and parameter inputs, then rerun the job. |
DSF074 | Discontinuity in protection log processing |
Explanation |
The first block of the protection log to be processed is not continuous with the last block processed before. Extracting block images for building the Delta Save images (DSIM) data set must proceed in sequence. The current position on the protection log and the last position of the previous PLCOPY execution are shown. No online save information will be extracted from the protection log during this ADARES execution. Building the DSIM data set is discontinued. The PLCOPY function will continue processing. When terminating normally, the function will set condition code 4. |
Action |
Rebuild the DSIM data set using the COPY function. |
DSF075 | DSIM dataset overflow |
Explanation |
The Delta Save images (DSIM) data set is not large enough to hold all block images written during the accompanying online save operation. This DSIM data set cannot be used for merging. The DSIM data set is set to an error status. The PLCOPY function will continue processing. When terminating normally, the function will set condition code 4. |
Action |
Enlarge the DSIM data set and rebuild it using the COPY function before performing the merge operation. |
DSF076 | DSIM dataset overflow |
Explanation |
The Delta Save images (DSIM) data set is not large enough to hold all block images written during the accompanying online save operation. This DSIM data set cannot be used for merging. The DSIM data set is set to an error status. The COPY function will continue processing. When terminating normally, the function will set condition code 4. If no sequential output data set was specified, a subsequent ADARES error abnormally terminates the function. |
Action |
Augment the DSIM data set and run the COPY function again before performing the merge operation. |
DSF079 | Illegal multiple use of DSIM dataset detected |
Explanation |
The Delta Save images (DSIM) data set was modified by another utility while
The DSIM data set is inconsistent. In ADASAV, the MERGE function is abnormally terminated. In ADARES, the DSIM data set is set to an error status. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Avoid parallel usage of the DSIM data set in the future. If the function was PLCOPY, rebuild the DSIM data set using the COPY function. If the function was COPY, rerun the COPY function. If the function was MERGE, rebuild the DSIM data set using the COPY function and rerun the MERGE function. |
DSF080 | Error occurred during execution of read DLOG ior-error-text ASSO RABN: dec-rabn (hex-rabn) |
Explanation |
An I/O error occurred when the Delta Save Facility was trying to read a block from the Delta Save logging (DLOG) area. An ADAIOR error text is given. The affected Associator RABN is shown in decimal dec-rabn and hexadecimal hex-rabn formats. The save function is abnormally terminated. |
Action |
Determine the cause of the I/O error and eliminate it. Remove the DLOG area and install it again. Perform a full save operation. |
DSF081 | Error occurred during execution of write DLOG ior-error-text ASSO RABN: dec-rabn (hex-rabn) |
Explanation |
An I/O error occurred when the Delta Save Facility was trying to write a block to the Delta Save logging (DLOG) area. An ADAIOR error text is given. The affected Associator RABN is shown in decimal dec-rabn and hexadecimal hex-rabn formats. The save function is abnormally terminated. |
Action |
Determine the cause of the I/O error and eliminate it. Remove the DLOG area and install it again. Perform a full save operation. |
DSF082 | Error occurred during execution of open DSIM ior-error-text |
Explanation |
An error occurred when the Delta Save Facility was trying to open the Delta Save images (DSIM) data set. An ADAIOR error text is given. The job control is probably incorrect, or the DSIMDEV parameter is missing or wrong. In ADASAV, the function is abnormally terminated. In ADARES, no online save information will be extracted from the protection log during this ADARES execution. Building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Check and correct the job control and/or the DSIMDEV parameter. If the function was ADARES PLCOPY, rebuild the DSIM data set using the ADARES COPY function. Otherwise rerun the job. |
DSF083 | Error occurred during execution of read DSIM ior-error-text RABN: dec-rabn (hex-rabn) |
Explanation |
An I/O error occurred when the Delta Save Facility was trying to read a block from the Delta Save images (DSIM) data set. An ADAIOR error text is given. The affected DSIM RABN is shown in decimal dec-rabn and hexadecimal hex-rabn formats. In ADASAV, the function is abnormally terminated. In ADARES, no more online save information will be extracted from the protection log during this ADARES execution. Building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Determine the cause of the I/O error and eliminate it. Rebuild the DSIM data set. |
DSF084 | Error occurred during execution of write DSIM ior-error-text RABN: dec-rabn (hex-rabn) |
Explanation |
An I/O error occurred when the Delta Save Facility was trying to write a block to the Delta Save images (DSIM) data set. An ADAIOR error text is given. The affected DSIM RABN is shown in decimal dec-rabn and hexadecimal hex-rabn formats. In ADASAV, the function is abnormally terminated. In ADARES, no more online save information will be extracted from the protection log during this ADARES execution. Building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Determine the cause of the I/O error and eliminate it. Rebuild the DSIM data set. |
DSF085 | Error occurred during execution of close DSIM ior-error-text |
Explanation |
An error occurred when the Delta Save Facility was trying to close the Delta Save images (DSIM) data set. An ADAIOR error text is given. In ADASAV, the function is abnormally terminated. In ADARES, the PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Determine the cause of the error and eliminate it. |
DSF086 | Error occurred while executing open input save dd-name ior-error-text |
Explanation |
An error occurred when the Delta Save Facility was trying to open an input save data set. The DD/link name of the data set and an ADAIOR error text are given. A job control statement is probably incorrect. The function is abnormally terminated. |
Action |
Determine the cause of the error and eliminate it. Rerun the job. |
DSF087 | Error occurred while executing read input save dd-name ior-error-text |
Explanation |
An error occurred when the Delta Save Facility was trying to read from an input save data set. The DD-name/link name of the data set and an ADAIOR error text are given. The function is abnormally terminated. |
Action |
Determine the cause of the error and eliminate it. If the save data set turns out to be readable, rerun the job. |
DSF088 | Error occurred while executing close input save dd-name ior-error-text |
Explanation |
An error occurred when the Delta Save Facility was trying to close an input save data set. The DD/link name of the data set and an ADAIOR error text are displayed. The function terminates abnormally. |
Action |
Determine the cause of the error and eliminate it. |
DSF089 | GETMAIN error - not enough virtual memory |
Explanation |
Sufficient virtual memory could not be obtained for Delta Save Facility processing. The number of bytes requested and obtained are shown in decimal and hex format. In ADASAV, the function is abnormally terminated. In ADARES, building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Increase the partition/region of the job. If the function was ADARES PLCOPY, rebuild the DSIM data set using the ADARES COPY function. Otherwise rerun the job. |
DSF090 | Incorrect database version |
Explanation |
The Delta Save Facility requires a database at Adabas version 5.3.3 or above. The requested function cannot be executed. The internal version indicator found in the GCBs is shown in hexadecimal format. The function is abnormally terminated. |
Action |
To use the Delta Save Facility, convert the database to Adabas version 5.3.3 or above. |
DSF091 | Incorrect version of DLOG area |
Explanation |
The Delta Save logging (DLOG) area was installed by another, incompatible version of the Delta Save Facility. The internal version indicator and the version of the Delta Save Facility software are displayed in hexadecimal format. The function is abnormally terminated. |
Action |
Use a compatible version of the Delta Save Facility software, or remove the DLOG area and install it again. |
DSF092 | Incorrect version of DSIM dataset |
Explanation |
The Delta Save images (DSIM) data set was created by another, incompatible version of the Delta Save Facility. The internal version indicator and the version of the Delta Save Facility software are displayed in hexadecimal format. In ADASAV, the function is abnormally terminated. In ADARES, building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Use a compatible version of the Delta Save Facility software, or rebuild the DSIM data set using the ADARES COPY function. |
DSF093 | Error during input save tape processing |
Explanation |
An error was detected while processing a record from an input save data set. Probably the save data set is invalid. The DD/link name of the save data set, an internal reason code, and the serial block number in decimal and hexadecimal are shown. The requested function cannot be completed. The function is abnormally terminated. |
Action |
Check for invalid concatenation of save data sets and correct it, if found. Consult your Software AG technical support representative, if necessary. |
DSF094 | Error during input save tape processing |
Explanation |
Either some important control information is not consistent for all records of an input save data set, or the serial block numbers within an input save data set are not in ascending order, increasing by one. Probably the save data set is invalid. The DD/link name of the save data set is shown. The function cannot be completed, and is abnormally terminated. |
Action |
Check for invalid concatenation of save data sets and correct it, if found. Consult your Software AG technical support representative, if necessary. |
DSF095 | Internal error during protection log processing |
Explanation |
An error was detected in a protection log block processed by the Delta Save Facility. The protection log number, the block number and offset within the block, and an internal reason code are displayed in decimal format, the block number and offset also in hex format. A DSIM data set cannot be built. Building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Check for and correct any mistake in the specification of protection log data sets. Consult your Software AG technical support representative, if necessary. |
DSF096 | Damaged DLOG area block detected |
Explanation |
An inconsistent block was encountered in the Delta Save logging (DLOG) area. The bad RABN is shown in decimal and hex format, plus an internal reason code. The Delta Save operation cannot be completed. The Delta Save operation is abnormally terminated. |
Action |
Consult your Software AG technical support representative to determine the cause of the error. Disable Delta Save logging, remove the DLOG area, and install it again. Perform a full save operation. |
DSF097 | Damaged DSIM block detected |
Explanation |
An inconsistent block was encountered in the Delta Save images (DSIM) data set. The bad RABN is shown in decimal and hex format, plus an internal reason code. The requested Delta Save Facility function cannot be completed. In ADASAV, the function is abnormally terminated. In ADARES, building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Consult your Software AG technical support representative to determine the cause of the error. Rebuild the DSIM data set using the ADARES COPY function. |
DSF098 | Damaged DLOG extension block detected |
Explanation |
An inconsistent block was encountered in a file-specific extension of the Delta Save logging (DLOG) area. The file number, the RABN of the inconsistent block, and an internal reason code are shown. A Delta Save operation is not possible. The Delta Save operation is abnormally terminated. |
Action |
Consult your Software AG technical support representative to determine the cause of the error. Save and restore or reorder the file in question. Then rerun the Delta Save operation. |
DSF099 | DSF internal error at module + offset trace: trace-info R0-R3 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx R4-R7 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx R8-R11 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx R12-R15 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx |
Explanation |
An internal error occurred in the indicated module at the specified offset. Some internal trace information as well as the register settings at the time of the error are shown. The requested Delta Save Facility function cannot be completed. In ADASAV, the function is abnormally terminated. In ADARES, building the DSIM data set is discontinued. The PLCOPY or COPY function will continue processing. When terminating normally, the function will set condition code 4. If no output data set was specified for the COPY function, a subsequent ADARES error abnormally terminates the function. |
Action |
Consult your Software AG technical support representative to determine the cause of the error. |