Version 8.1.4
 —  Messages and Codes  —

ADAWRK Error Messages

Overview of Messages

ERROR-121 | ERROR-122 | ERROR-123 | ERROR-124 | ERROR-125 | ERROR-126 | ERROR-127 | ERROR-128 | ERROR-129 | ERROR-130 | ERROR-131 | ERROR-132 | ERROR-133 | ERROR-134 | ERROR-135 | ERROR-136 | ERROR-137 | ERROR-138 | ERROR-139 | ERROR-140 | ERROR-141 | ERROR-142 | ERROR-143 | ERROR-144 | ERROR-145 | ERROR-146 | ERROR-147 | ERROR-148 | ERROR-149 | ERROR-150 | ERROR-151 | ERROR-152 | ERROR-153 | ERROR-154 | ERROR-155 | ERROR-156 | ERROR-157 | ERROR-158 | ERROR-159 | WARN-001 | WARN-002 | WARN-003 | WARN-004 | WARN-005 | WARN-006 | WARN-007 | WARN-008

ERROR-121 Invalid value for parameter TIMEZONE. TIMEZONE must be set to MACHINE, LOCAL, or an integer value in the range -23 to +23. When entering + OR -, enclose the number in single quotes. e.g. TIMEZONE='+5'
Explanation

An invalid value was specified for the TIMEZONE parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-122 Invalid value for parameter CHECKPOINT. Must be set to YES or NO.
Explanation

An invalid value was specified for the CHECKPOINT parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-123 Invalid value for parameter DTP. Must be set to YES, NO or DETAIL.
Explanation

An invalid value was specified for the DTP parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-124 Invalid value for parameter FORCE. Must set to YES or NO.
Explanation

An invalid value was specified for the FORCE parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-125 Invalid value for parameter REPLICATION. Must be set to YES, NO or DETAIL.
Explanation

An invalid value was specified for the REPLICATION parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-126 Invalid value for parameter REPORTFILE. Must be set to YES or NO.
Explanation

An invalid value was specified for the REPORTFILE parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-127 Invalid value for parameter SUMMARY. Must be set to YES or NO.
Explanation

An invalid value was specified for the SUMMARY parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-128 Invalid value for parameter TRANSACTIONS. Must be set to YES, NO or FULL.
Explanation

An invalid value was specified for the TRANSACTIONS parameter.

Action

Supply the correct parameter value and rerun the ADAWRK job.


ERROR-129 Invalid value for parameter FILES. File number provided must be > 0 and < 65536.
Explanation

An invalid value was specified for the FILES parameter.

Action

Supply a file number in the correct range and rerun the ADAWRK job.


ERROR-130 Invalid range for parameter FILES. When file range provided, VALUE1 < VALUE2.
Explanation

An invalid value was specified for the FILES parameter.

Action

Ensure that when providing a range of file numbers the first value (VALUE1) is less than the second value (VALUE2), then rerun the ADAWRK job.


ERROR-131 IOR cccc call failed return code rc
Explanation

An internal call failed.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-132 Cannot identify Work datasets as no Work datasets were provided in the JCL and NOPPT was specified
Explanation

ADAWRK was unable to find Work data sets.

Action

Either include statements for the Work data sets in the JCL or remove the NOPPT parameter.


ERROR-133 TIMESTAMP mismatch on Work dataset
Explanation

ADAWRK detected inconsistent timestamps in the Work data set provided.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-134 Work dataset dsn has wrapped
Explanation

ADAWRK detected that the Work data set has wrapped and that old protection data has been overwritten. The Work data set name (dsn) is given in the message.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-135 While processing a non cluster Work, a cluster nucleus Work block was found
Explanation

While processing a Work data set from a non-cluster nucleus, ADAWRK detected a work block that originated from a cluster nucleus.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-136 While processing a cluster Work dataset, a non cluster nucleus Work block was found
Explanation

While processing a Work data set from a cluster nucleus, ADAWRK detected a work block that originated from a non-cluster nucleus.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-137 Work block size value longer than Work block size
Explanation

While processing a Work data set, ADAWRK detected a work block with a size indicator greater than the block size of the work block.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-138 Invalid version in Work block
Explanation

While processing a Work data set, ADAWRK detected a work block with a version number that is not supported.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-139 Invalid database ID in Work block
Explanation

While processing a Work data set, ADAWRK detected a work block with a different database ID.

Action

Ensure that you have not mixed the Work files you are passing to ADAWRK.


ERROR-140 Invalid timestamp in Work block
Explanation

While processing a Work data set, ADAWRK detected a work block with an invalid timestamp.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-141 Invalid HSI record in Work block
Explanation

While processing a Work data set, ADAWRK detected a work block with an invalid HSI record.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-142 Cluster nucleus Work dataset time stamps did not occur in chronological order
Explanation

While processing a cluster Work data set, ADAWRK detected timestamps that are not in the correct order.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-143 Recovery data found on provided Work datasets
Explanation

While processing the specified Work data sets, ADAWRK was unable to detect any recovery data.

Action

Ensure that you have not mixed the Work files you are passing to ADAWRK.


ERROR-144 Parameter DTP is not currently supported
Explanation

The DTP parameter is not yet supported.

Action

Remove the parameter and resubmit the job.


ERROR-145 Parameter REPLICATION is not currently supported
Explanation

The REPLICATION parameter is not yet supported.

Action

Remove the parameter and resubmit the job.


ERROR-146 Invalid nucleus ID in Work block
Explanation

While processing the Work data set, an invalid nucleus ID was detected.

Action

Ensure that you have not mixed the Work files you are passing to ADAWRK.


ERROR-147 Userid cannot exceed 8 bytes
Explanation

A user ID longer than eight bytes was specified when providing a user ID to be used for selecting transactions.

Action

Correct the user ID and resubmit the job.


ERROR-148 Missing Work dataset entry in PPT block
Explanation

When processing the PPT block in the specified Associator data set, a missing entry was detected.

Action

Contact your Software AG technical support representative for assistance.


ERROR-149 Dynamic allocation/open Work failed
Explanation

When trying to dynamically allocate or open the Work data sets, a failure occurred.

Action

Investigate the cause of the error. Contact your Software AG technical support representative for assistance.


ERROR-150 Insufficient workpool space for buffers
Explanation

ADAWRK encountered a shortage of space in the Work pool during execution.

Action

Check JCL, increase region size, and resubmit the job. If the problem persists, contact your Software AG technical support representative for assistance.


ERROR-151 I/O error reading a Work dataset
Explanation

ADAWRK encountered an I/O error reading a Work data set.

Action

Review the additional error message accompanying this message and rectify the problem. Then resubmit the job.


ERROR-152 I/O error reading PPT
Explanation

ADAWRK encountered an I/O error reading the PPT.

Action

Review the additional error message accompanying this message and rectify the problem. Then resubmit the job.


ERROR-153 Inconsistent Work datasets provided
Explanation

ADAWRK detected inconsistencies in the Work data sets provided.

Action

Contact your Software AG technical support representative with the details of this message.


ERROR-154 Parameter LWP must be specified in, e.g LWP=512K
Explanation

The value provided for the LWP parameter must be specified in kilobytes.

Action

Provide a value for LWP in kilobytes and try again.


ERROR-155 Parameter LWP error : must be between 100K and 1048576K
Explanation

The value provided for the LWP parameter is not in the correct range.

Action

Provide a value for LWP in the correct range and try again.


ERROR-156 Parameter error(s) detected
Explanation

This message appears when errors have been detected in parameter processing.

Action

Messages indicating which parameters are in error will have been issued earlier. Refer to these other error messages to resolve the issue. Then try again.


ERROR-157 No space in Work pool to satisfy request
Please review the settings of the LWP parameter.
Explanation

An internal ADAWRK storage request has failed.

Action

Consider increasing the setting of the ADAWRK LWP (length of Work pool) parameter. If this does not resolve the issue, contact your Software AG technical support representative for assistance.


ERROR-158 All Work datasets for nuclei referred to in Work-part-1 data not provided.
Explanation

Records have been detected in the Work part 1 data referring to clustered nuclei, but the work data sets for the other nuclei have not been provided as input to ADAWRK in JCL. Inconsistent ADAWRK output may result.

Action

Ensure that all Work data sets for all component nuclei of the cluster are included as input to ADAWRK. Then try again.


ERROR-159 Invalid value for parameter FILES. File number specified more than once.
Explanation

The same file number has been specified more than once in the ADAWRK FILES parameter. This is invalid.

Action

Correct the parameter and try again.


WARN-001 A timestamp was encountered reading the Work datasets indicating that ADAWRK is running against a running Adabas nucleus. ADAWRK will continue.
Explanation

ADAWRK detected that the Work data sets it is reading are being used by an active database.

Action

No action is required for this informational message.


WARN-002 Flush point values not established
Explanation

While processing the specified Work data sets, ADAWRK was unable to determine the flush point.

Action

No action is required for this informational message.


WARN-003 End of buffer flush values not established
Explanation

While processing the specified Work data sets, ADAWRK was unable to determine the end of buffer flush point.

Action

No action is required for this informational message.


WARN-004 Start of buffer flush values not established
Explanation

While processing the specified Work data sets, ADAWRK was unable to determine the start of buffer flush point.

Action

No action is required for this informational message.


WARN-005 Backward repair point values not established
Explanation

While processing the specified Work data sets, ADAWRK was unable to determine the backward repair point.

Action

No action is required for this informational message.


WARN-006 Work dataset dsn found in PPT but not provided to ADAWRK.
Explanation

The PPT refers to a Work data set that has not been provided as input to ADAWRK in JCL. It may be that the data set has been omitted in error. Inconsistent ADAWRK output may result.

Action

If the data set was not intentionally excluded from the run, include the relevant data set as input to ADAWRK. Then try again.


WARN-007 Work dataset dsn not found in PPT but provided to ADAWRK
Explanation

The PPT does not refer to a Work data set that has been provided as input to ADAWRK in JCL. It may be that the data set has been included in error. Inconsistent ADAWRK output may result.

Action

If the data set was not intentionally included from the run, remove the relevant data set as input to ADAWRK. Then try again.


WARN-008 Work dataset for nucleus that triggered the last buffer flush not provided
Explanation

The Work data set for the nucleus that triggered the last buffer flush has not been provided as input to ADAWRK in JCL. Inconsistent ADAWRK output may result.

Action

If the data set was not intentionally excluded from the run, include the relevant data set as input to ADAWRK. Then try again.


Top of page