IBM has dropped support for the old z/VSE assembler and Software AG supports assembling the Adabas 7 link components with the high-level assembler only.
The Adabas link routines now have AMODE and RMODE assembly directives in the source. These allow the linkage editor to produce warning messages when conflicting AMODE or RMODE linkage editor control statements are encountered in the link JCS or EXECs.
These assembly directives also serve to document the preferred AMODE and RMODE for each link routine. It is important to note that in and of themselves, these directives do not alter the actual addressing mode of the link routine during execution.
The batch link routine ADALNK has the following AMODE and RMODE assembly directives:
ADABAS AMODE 31 ADABAS RMODE 24
Software AG recommends RMODE 24 for the z/VSE non-reentrant batch link routine (ADALNK.PHASE).
These directives may be changed by modifying the source members before assembling them, or they may be overridden by linkage editor control statements. For example, to link the batch ADALNK module with AMODE31 and an RMODE ANY, the following control statements may be provided as input to the linkage editor:
PHASE ADALNK,* MODE AMODE(31),RMODE(ANY)
The linkage editor control statements override the Assembler directives in the source module.
For more information about the AMODE and RMODE directives and their effects on the assembler, linkage editor, and execution, consult IBM's VSE Extended Addressability Guide.
When re-linking the Adabas 8 link routines with certain
AMODE
and RMODE
combinations, a
warning message may be generated by the linkage editor. This may be safely
ignored as long as it pertains to a conflict of AMODE
or
RMODE
in the ESD record of one or more of the load
modules that comprise the link routine, and as long as the resulting module has
the proper AMODE
and RMODE
attributes for execution with the intended calling application programs.
Care must be taken to ensure that AMODE(24)
applications will operate properly when invoking the link routine with the
attributes chosen when it is re-linked. This is particularly important if the
RMODE(ANY)
attribute is associated with a link routine
that will be loaded dynamically but invoked by a program that is
AMODE(24)
. In this case, the link routine should be
re-linked AMODE(31)
,RMODE(24)
to
avoid addressing exception ABENDs because the AMODE(24)
application cannot correctly invoke the link routine if it resides above the
16-megabyte line.
The Adabas 8 link routines all run AMODE(31)
after initialization, but they will return to the caller in the caller's
AMODE
.
Note:
Under CICS, the V8 links run AMODE(31)
, but
the Dataloc RDO parameter governs the AMODE
and
RMODE
of the running CICS transaction.
The batch z/VSE link routine, ADALNK
, has been
assembled and link-edited
AMODE(31
,RMODE(24)
. This provides
the most flexible configuration for most z/VSE applications that will invoke
it. It may be re-linked
AMODE(31)
,RMODE(ANY)
, but you
must be certain that no AMODE(24)
applications will
invoke it.
The reentrant batch link routine, ADALNKR
, has
been assembled
AMODE(31)
,RMODE(24)
. It may be
re-linked AMODE(31)
,RMODE(ANY)
if
no AMODE(24)
applications will invoke it.
The z/VSE Com-plete link routine, ADALCO
, has
been assembled and link-edited
AMODE(31)
,RMODE(24)
, and this is
the required configuration for ADALCO
under z/VSE
Com-plete because ADALCO
still uses z/VSE macros and
services which require it to reside below the 16-megabyte line.
All of the Adabas 8 CICS link routine modules -
ADACICS
, ADACICT
,
ADACIC0
, and ADACIRQ
- have been
assembled and link-edited
AMODE(31)
,RMODE(ANY)
. CICS
manages the loading of programs and their invocation depending on the
DATALOC
values associated with their program and
transaction definitions.
Software AG recommends that all batch applications invoke Adabas calls
through the ADAUSER module. This module is normally link-edited with the
application program and it then loads the appropriate link routine as well as
ADARUN and ADAIOR/ADAIOS. The source member has the
AMODE
and RMODE
directives coded
as AMODE 31
, RMODE ANY
. This is
the most flexible configuration for assembling and linking ADAUSER with the
widest variety of application programs. However, if ADAUSER is dynamically
loaded, either the RMODE
assembler directive should be
changed to RMODE 24
before re-assembling it or the
ADAUSER module should be re-linked
AMODE(31)
,RMODE(24)
to ensure
that AMODE 24
application programs may invoke it
properly below the 16-megabyte line.
For prior versions of Adabas, UES is enabled by default for only the batch and Com-plete link routines. As of Adabas version 8, UES is enabled by default for all link routines, including the CICS link routines. It is not necessary to disable UES support. Applications that do not require UES translation continue to work properly even when the UES components are linked with the Adabas link routines. See the section Enabling Universal Encoding Support (UES) for Your Adabas Nucleus for more information.
This section covers the following topics:
By default, the load modules for all Adabas 8 link routines have been linked with LNKUES and the default translation tables.
LNKUES converts data in the Adabas buffers and byte-swaps, if necessary, depending on the data architecture of the caller.
The two standard translation tables are:
ASC2EBC: ASCII to EBCDIC translation; and
EBC2ASC: EBCDIC to ASCII translation.
The Adabas translation table pair is provided in the section Translation Tables.
You may use the load modules with the default translation tables linked in, or you may prepare your own customized translation tables, re-assemble the tables, and link them with the LNKUES module that is delivered.
Notes:
LNKUES is called only on Adabas link routine request (X'1C') and reply (X'20') calls if the first byte of the communication ID contains X'01' and the second byte does not have the EBCDIC (X'04') bit set. In Adabas 8 requests, LNKUES receives control before UEXIT1. In Adabas 8 replies, LNKUES receives control after UEXIT2.
The following lists the sample jobs provided to manage universal encoding support in Adabas link routines in z/VSE environments:
Sample Job | Description |
---|---|
ALNKCIC8.X | Assembles and links the CICS globals table with LNKUES and the default translation tables ASC2EBC and EBC2ASC. |
ALNKLCO8.X | Relinks the Com-plete link routine with the LCOGBL link globals table, LNKUES, and the default translation tables ASC2EBC and EBC2ASC. |
ALNKLNK8.X | Relinks the batch link routine with the LNKGBLS link globals table, LNKUES, and the default translation tables ASC2EBC and EBC2ASC. |
ALNKLNR8.X | Relinks the reentrant batch link routine with the LNKRGBL link globals table, LNKUES, and the default translation tables ASC2EBC and EBC2ASC. |
Before you can use any of these jobs, they should be edited to prepare the job power statements, provide the proper names for the procedures and libraries referenced, and all necessary extent and volume information. Refer to the comments in the jobs themselves for more information.
This section describes how to disable UES support in the Adabas 8 Com-plete and batch link routines, if for some reason you feel it is necessary.
To disable UES support in link routines:
Edit the link globals table for the associated link routine. Set the UES parameter setting to NO.
Assemble the link globals table after making any other necessary modifications to any other keyword directives in the source module as required by your installation.
Link the Adabas link routine with the newly assembled link globals table and do not include any of the UES components (that is, LNKUES, ASC2EBC, or EBC2ASC).
For more information about the specific link routines, read Installing Adabas with Com-plete under Adabas 8, and Installing Adabas with Batch under Adabas 8.
The Adabas command-level link routine supports the CICS transaction server (TS) 1.1 running under z/VSE 2.4 and above.
How Adabas is installed on CICS-based systems depends on the level of CICS being run:
The command-level link from Adabas 8.1 cannot be used with CICS/VSE 2.3. Instead, you must use the command-level link routine for Adabas Version 7.4.4 or the macro-level link routine provided in source in the 7.4.4 VSE sublibrary with CICS/VSE 2.3 environments.
CICS TS 1.1 running under z/VSE 2.4 and above must run a current version of Adabas and use the command-level link component.
Note:
The OPID option for the USERID field is not supported under CICS/VS
2.3 and above; therefore, it is not provided with the command-level link
routine.
This section covers the following topics:
IBM has not announced a date for end of service for CICS/VSE 2.3. Consequently, Software AG will continue to support the Adabas CICS 7.4.4 link routines, particularly the macro-level ADALNC routine on systems running CICS/VSE 2.3 until IBM drops support for that level of CICS.
For CICS/TS 1.1 and above for VSE, the Adabas 8.1.4 CICS link components are supported and the Adabas CICS 7.4 link routines will not be supported when general support for Adabas 7.4.4 is terminated by Software AG.
If you run the Adabas CICS command-level link routine with the CICS multiple region option (MRO), you must set the ADAGSET option MRO=YES and use the default value for the ADAGSET NETOPT option.
You can use the ADAGSET NTGPID option to provide a 4-byte literal for the Adabas communication ID to be used by the Adabas SVC when applications that call Adabas span multiple application regions.
Alternatively, you can create a user exit B (UEXITB) for the link routine that
sets UBFLAG1 (byte X'29' in the UB DSECT) to a value of X'08' (UBF1IMSR); and
places a 4-byte alphanumeric value in the UB field UBIMSID.
The exit then allows the Adabas SVC to provide a proper Adabas communication ID in the Adabas command queue element (CQE) even when transactions originate in multiple regions.
Under CICS/TS 1.1 and above for z/OS and z/VSE, the preferred method for defining and installing CICS programs and transactions is RDO (resource definition online). The CICS documentation no longer recommends the assembly of PPT and PCT entries to define resources.
The following table provides sample RDO definitions for the Adabas CICS command-level link components. The data has been extracted directly from the CICS CSD file and should be used as a guide for providing comparable information on the CEDA panels.
********************************************************************** * Sample DEFINE control statements for the DFHCSDUP utility. * For Adabas CICS command-level link routine components. * * These control statements can be used as input to the DFHCSDUP * CICS CSD update utility to define the Adabas CICS command-level * link routine components on a CICS/TS system. ********************************************************************** DEFINE PROGRAM(ADABAS) GROUP(ADABAS) DESCRIPTION(ADABAS V74s COMMAND LEVEL LINK ROUTINE) LANGUAGE(ASSEMBLER) RELOAD(NO) RESIDENT(YES) USAGE(NORMAL) STATUS(ENABLED) CEDF(YES) DATALOCATION(ANY) EXECKEY(CICS) EXECUTIONSET(FULLAPI) DEFINE PROGRAM(ADACIC0) GROUP(ADABAS) DESCRIPTION(ADABAS V74s PLTPI ENABLE ADATRUE PROGRAM) LANGUAGE(ASSEMBLER) RELOAD(NO) RESIDENT(NO) USAGE(NORMAL) STATUS(ENABLED) CEDF(YES) DATALOCATION(ANY) EXECKEY(CICS) EXECUTIONSET(FULLAPI) DEFINE PROGRAM(ADATEST) GROUP(ADABAS) DESCRIPTION(ADABAS V74s DISPLAY GWA PROGRAM - DISPGWA) STATUS(ENABLED) CEDF(YES) DATALOCATION(ANY) EXECKEY(CICS) EXECUTIONSET(FULLAPI) DEFINE PROGRAM(ADATRUE) GROUP(ADABAS) DESCRIPTION(ADABAS V74s TASK RELATED USER EXIT) LANGUAGE(ASSEMBLER) RELOAD(NO) RESIDENT(YES) USAGE(NORMAL) STATUS(ENABLED) CEDF(YES) DATALOCATION(ANY) EXECKEY(CICS) EXECUTIONSET(FULLAPI) DEFINE TRANSACTION(DGWA) GROUP(ADABAS) DESCRIPTION(TRANSACTION TO DISPLAY ADABAS GWA) PROGRAM(ADATEST) TWASIZE(128) PROFILE(DFHCICST) STATUS(ENABLED) TASKDATALOC(ANY) TASKDATAKEY(CICS) STORAGECLEAR(NO) RUNAWAY(SYSTEM) SHUTDOWN(DISABLED) DYNAMIC(NO) PRIORITY(1) TRANCLASS(DFHTCL00) DTIMOUT(NO) INDOUBT(BACKOUT) RESTART(NO) SPURGE(NO) TPURGE(NO) DUMP(YES) TRACE(YES) RESSEC(NO) CMDSEC(NO)
—where s is the system maintenance level of Adabas.
These sample DEFINE statements are located in member DEFADA7 in the Adabas sublibrary. They can be modified and used as input to the IBM DFHCSDUP utility to define the Adabas CICS command-level components. Consult the appropriate IBM CICS documentation for information on the DFHCSDUP utility.
The following table lists the modules supplied in your Adabas installation to support the installation of Adabas 8 with CICS TP monitors.
Note:
The Adabas 8 installation supports Adabas 7 direct calls in addition
to Adabas 8 calls; however, an Adabas 7 installation does not support Adabas 8
direct calls.
Module | Description |
---|---|
ADACIC0.OBJ | CICS initialization program code object module. |
ADACIC0.PHASE | CICS initialization executable module. |
ADACICS.OBJ | CICS TP monitor program code object module. This module is linked with ADADCI.OBJ to produce ADACICS.PHASE. |
ADACICS.PHASE | CICS TP monitor executable module. |
ADACICT.OBJ | CICS task-related user exit (TRUE) program code object module, dependent part. This module is linked with LNKCIM.OBJ to produce ADACICT.PHASE. |
ADACICT.PHASE | CICS TRUE executable module. |
ADACIRQ.OBJ | Extra-partition transient data queue handler program code object module. |
ADACIRQ.PHASE | Extra-partition transient data queue handler object module executable module. |
ADADCI.OBJ | Direct call interface program code object module. This module is linked with ADACICS.OBJ to produce ADACICS.PHASE. |
CICSGBL.A | Sample link globals table. This module is modifiable. Once it is modified, you can use the ALNKCIC8.X sample JCS to assemble the CICSGBL.A module, producing the CICSGBL.OBJ object module and then link-editing all relevant CICS program code object modules to create the relevant CICS phases required for Adabas 8 support. |
CICSGBL.OBJ | Link globals table object module. |
CICSGBL.PHASE | Link globals table executable module. This module is identified via DDLINK. |
LNKCIC0.OBJ | CICS link book used when applying maintenance with MSHP to link-edit ADACIC0.OBJ to produce ADACIC0.PHASE. |
LNKCICG.OBJ | CICS link book used when applying maintenance with MSHP to link-edit the CICSGBL.OBJ globals table and produce CICSGBL.PHASE. |
LNKCICS.OBJ | CICS link book used when applying maintenance with MSHP to link-edit ADADCI.OBJ and ADACICS.OBJ to produce ADACICS.PHASE. |
LNKCICT.OBJ | CICS link book used when applying maintenance with MSHP to link-edit ADACICT.OBJ and LNKCIM.OBJ to produce ADACICT.PHASE. |
LNKCIM.OBJ | CICS task-related user exit (TRUE) product code object module, independent part. This module is linked with ADACICT.OBJ to produce ADACICT.PHASE. |
LNKCIRQ.OBJ | CICS link book used when applying maintenance with MSHP to link-edit ADACIRQ.OBJ to produce ADACIRQ.PHASE. |
To install the Adabas 8 CICS link routine components, complete the following steps:
Modify the CICS startup JCS to include the Adabas 8 sublibrary in the LIBDEF chain.
Modify the sample CICSGBL.A member found in the Adabas 8 sublibrary. This member contains sample default installation (LGBLSET) parameter settings. For more information about what to modify in this member, read Modifying Source Member Defaults (LGBLSET Macro) in Version 8.
Note:
The setting for the OPSYS parameter must be z/VSE.
Save the modified CICSGBL.A member with a unique name in an appropriate user sublibrary.
Using sample job ALNKCIC8.X, assemble and link-edit the member you saved in the previous step into a sublibrary that will be made available to CICS in the LIBDEF concatenation. Note that any user or Software AG link routine exits should be link-edited with this load module. (For information about specific Software AG product exits, read the installation documentation for the product.)
Modify the DEFADA8.A member to provide the correct name of the link routine globals default table created in the previous step (Step 4). The default module name is CICSGBL. Tailor this member for any other CICS installation values as required.
Note:
The Adabas 8 CICS program names, other than the name of the link
globals table, are predefined and cannot be changed (for example, ADACICS,
ADACICT, ADACIRQ, and ADACIC0).
Run the IBM DFHCSDUP utility to update the CICS CSD file for the desired CICS using the modified DEFADA8 member as input.
Modify the CICS PLTPI table to add the entries that will enable and start the Adabas CICS task-related user exits (TRUE). Use member ADAPLTXX.A from the Adabas 8 sublibrary as a sample for enabling and starting a legacy Adabas TRUE and the new Version 8 TRUE in the second phase of the PLT.
Assemble and link the modified PLTPI table into a library that will be available to the desired CICS region.
Update a Destination Control Table (DCT) to include the entries found in member DCTAV8.A in the Adabas 8 sublibrary. Assemble and link-edit this table with a unique suffix into a sublibrary that will be made available to CICS. Modify the CICS SIT parameters to reference the updated DCT.
Modify the CICS startup JCL to include the DDLINK DLBL and EXTENT statements that provide the name of the link globals table prepared in Step 4. For more information on doing this, read Preparing DDLINK Input for CICS.
Start the CICS and note any messages relating to the installation of the Adabas TRUE modules that appear on the console.
Operation of the Adabas 8 CICS link routines may be tailored for each CICS partition by assembling and linking a link globals defaults table and making that table available to CICS at execution. The table may have any legal phase name that is acceptable to CICS and that does not conflict with existing program names used in the CICS region.
The globals table must be defined to CICS as a program. Review the provided sample DEFADA8.A member found in the Adabas 8 sublibrary to see a definition of the sample called CICSGBL. The DEFADA8.A member should be modified as necessary and provided as input to the DFHCSDUP utility to define the Adabas 8 components in the CICS CSD. This process is also described as part of the installation procedure under Adabas 8. Consult the IBM CICS documentation for information on the DFHCSDUP utility.
Each link routine globals table for a CICS region may have a unique name. The Adabas 8 CICS link routines are provided this name through an extra-partition transient data queue. The queue-name is ADAI and its definition is provided in the sample DCT macro definitions found in member DCTAV8.A. Copy this member into a complete DCT member intended for the CICS. The DCTAV8.A member contains the following DFHDCT definitions:
DFHDCT TYPE=SDSCI, + DSCNAME=DDLINK, + DEVICE=DISK, + RECFORM=FIXUNB, + RECSIZE=80, + BLKSIZE=80, + TYPEFLE=INPUT DFHDCT TYPE=EXTRA, + DSCNAME=DDLINK, + DESTID=ADAI
Assemble and link-edit the modified DCT member with a unique suffix (for example, DFHDCTxx where xx is the unique suffix). Modify the CICS SIT DCT parameter to provide the suffixe, DCT=xx.
When the Adabas 8 task-related user exit (TRUE) is enabled via the ADACIC0 program, either at CICS startup or with the ADA0 transaction, the ADACIRQ module is invoked and reads the ADAI transient data queue. The data read is provided in a file. The CICS JCS must be modified to provide this file's DLBL/EXTENT information or the default link globals table name "CICSGBL" will be used. If no link globals table is located, the Adabas 8 TRUE will not be enabled and started.
The format of the input data to be read is:
Content | Description |
---|---|
ADALNK | This keyword must appear in columns 1 through 6. |
space | A blank space must appear in column 7. |
LGTNAME=
or LGT= |
The keyword LGTNAME or LGT, followed by an equals sign (=) must appear after the space in column 7, starting in column 8. |
module-name | The module name of the prepared link globals table must appear after the equal sign that follows the LGTNAME or LGT keyword. |
For example, the following might be placed in a file:
ADALNK LGTNAME=LNKCI02
In this example, the link default globals table named "LNKCI02" must be prepared, assembled, link-edited, and defined to this CICS.
The Adabas 8 z/VSE CICS link routine installation program, ADACIC0 invokes the ADACIRQ program to read the DDLINK extra-partition file. This file contains the card that provides the name of the link globals table to use for the CICS where the link routines are being installed. The Adabas installation sublibrary contains member DDLINK.X as a sample card for this purpose. This member may be modified to provide the name of the link globals table of your choice.
This data needs to be placed in a SAM file so it may be read by the ADACIRQ program. This can be done in at least three ways:
Use the OBJMAINT program to copy a card from SYSIPT to a disk file. Sample job CPYDDL.X may be modified for this purpose.
Use LIBR to punch a modified version of the DDLINK.X member to a disk file. Tailor a JCS member to assign SYSPCH to the disk file and punch the member from a sublibrary using the FORMAT=NOHEADER keyword on the PUNCH statement. The control statements should be:
// EXEC LIBR,PARM='MSHP' ACCESS SUBLIB=SAGLIB.ADAvrs PUNCH DDLINK.X FORMAT=NOHEADER /*
Use DITTO to copy the card image from SYSIPT to a disk file.
Once the disk file has been created with the card image, the CICS execution JCS should be modified to add the following DLBL and extent cards:
// DLBL DDLINK,'ADABAS.ADA8.DDLINK',0,SD // EXTENT SYSnnn,vvvvvv ASSN SYSnnn,DISK,VOL=vvvvvv,SHR
The following table lists the modules supplied in your Adabas installation to support the installation of Adabas with Com-plete TP monitors.
Note:
The Adabas 8 installation supports Adabas 7 direct calls in addition
to Adabas 8 calls; however, an Adabas 7 installation does not support Adabas 8
direct calls.
Supplied Module | Description |
---|---|
ADALCO.PHASE | Com-plete TP monitor executable module. |
LCOGBL.A | Link globals table source module. This module is modifiable. Once it is modified, you can use sample job ALNKLCO8.X to assemble an LCOGBL.OBJ module . This sample job also link-edits the LCOGBL.OBJ module with LCOVSE8.OBJ to produce ADALCO.PHASE. |
LCOGBL.OBJ | Link globals table object module assembled from LCOGBL.A. |
LCOVSE8.OBJ | Com-plete TP monitor program code object module. |
LNKLCO.OBJ | Com-plete link book containing link-edit control cards used when applying maintenance with MSHP to link-edit LCOGBL.OBJ and LCOVSE8.OBJ to produce ADALCO.PHASE. |
Certain Adabas parameters are required by Com-plete, Software AG's TP monitor, when installing Adabas. For more information, see the Com-plete System Programmer's manual.
Software AG's TP monitor, Com-plete, requires an Adabas link routine if it is to communicate with Adabas databases, use Software AG's Entire Net-Work product, or use products like Entire System Server running under Com-plete. At this time, Com-plete does not support a mixed Adabas 7 and Adabas 8 link routine environment; thus Com-plete must be run with either an Adabas 7 link routine or an Adabas 8 link routine.
The Adabas Version 8 link routine is delivered in member ADALCO of the Adabas 8 sublibrary. This member must be linked with a link globals module you prepare and with any link routine exits you require to create the final ADALCO load module that is loaded by Com-plete when Com-plete is initialized. The final ADALCO load module and any exits linked with it must be reentrant.
To prepare the Adabas 8 link routine:
Edit the LCOGBL.A member in the Adabas 8 distribution sublibrary. LCOGBL.A is a module containing LGBLSET parameters that are used to create default settings for Com-plete link components. A complete description of LGBLSET parameters can be found in Modifying Source Member Defaults (LGBLSET Macro) in Version 8.
Note:
The OPSYS parameter must be set to z/VSE.
Modify and run the ALNKLCO8.X member to assemble and link-edit the link globals table you updated in the previous step.
The ALNKLCO8.X member will assemble and catalog the link globals table for Com-plete and link it with the Com-plete link routine, LCOVSE8.OBJ and any required exits. The ALNKLCO8.X member provides link-edit control cards for the inclusion of the Adabas 8 LNKUES module with the ASC2EBC and EBC2ASC translation tables.
Place the final phase, ADALCO, in a library that will be part of the Com-plete LIBDEF search chain.
Note:
The defaults set in the link globals table for Com-plete are
primarily for documentation purposes. The Adabas/Com-plete interface module,
TLOPADAB, sets values for Adabas target ID and SVC number on each Adabas call.
However, it is necessary to include the link globals table object module and
any necessary exits, including user exits when linking the Adabas 8
ADALCO.PHASE. If user exits are to be linked with ADALCO, be certain to code
the LGBLSET keywords accordingly.
The Adabas 8 link routine is prepared.
ADALNK is the standard Adalink for running Adabas in batch. ADALNKR (LNKVSER) is supplied as a reentrant batch link routine.
Batch applications should be linked with the ADAUSER module to provide the greatest degree of application calling isolation when invoking the Adabas batch link routines. The ADAUSER module will provide code to load the appropriate link routine and the supporting ADARUN and ADAIOR modules. ADARUN, in turn, loads other modules. To start a user program linked with ADAUSER, the following modules must be available in the LIBDEF search chain: ADAIOR, ADAIOS, ADALNK, ADAMLF, ADAOPD, ADAPRF, and ADARUN. In addition, ADAUSER reads DDCARD input from SYSIPT or DISK to allow jobstep setting of the database ID, Adabas SVC number, and other parameters.
For non-reentrant operation, the DDCARD input should provide the keyword PROG=USER. This causes ADARUN to load ADALNK for non-reentrant batch operations.
If you want to use reentrant batch operations, the ADAUSER module can still be linked with the application program, but the PROG=RENTUSER keyword must be coded on the DDCARD input. ADAUSER is, however, non-reentrant. For full reentrant batch applications, it will either need to be loaded (CDLOAD) separately, or the ADALNKR.PHASE must be loaded without using the ADAUSER module. In this case, the default values for DBID, SVC number, length of user information, and which exits are to be used is provided by the linked link globals table, as modified (read Installing the Reentrant Batch z/VSE Adabas 8 Link Routine. It is also possible to zap the ADALNKR.PHASE or LNKVSER8.OBJ module with these defaults, but Software AG recommends coding and linking the link globals table instead. Additional information on using a reentrant batch link routine is also provided in Required Application Reentrancy Propertie.
This section covers the following topics:
The following table lists the modules supplied in your Adabas installation to support the installation of Adabas 8 with batch.
Note:
The Adabas 8 installation supports Adabas 7 direct calls in addition
to Adabas 8 calls; however, an Adabas 7 installation does not support Adabas 8
direct calls.
Module | Description |
---|---|
ADALNK.PHASE | Batch executable module. |
ADALNKR.PHASE | Batch reentrant executable module. |
LNKGBLS.A | Batch link globals table. This module is modifiable. Once it is modified, you can use the ALNKLCO8.X sample JCS to assemble the LNKGBLS.A module, producing the LNKGBLS.OBJ module and then link-editing the LNKGBLS.OBJ module with the LNKVSE8.OBJ module to create the ADALNK.PHASE. |
LNKGBLS.OBJ | Batch link globals table object module assembled from LNKGBLS.A. |
LNKRGBL.A | Batch reentrant link globals table. This module is modifiable. Once it is modified, you can use the ALNKLNR8.X sample JCS to assemble the LNKRGBL.A module, producing the LNKRGBL.OBJ module and then link-editing the LNKRGBL.OBJ module with the LNKVSER8.OBJ module to create the ADALNKR.PHASE. |
LNKRGBL.OBJ | Batch reentrant link globals table object module assembled from LNKRGBL.A. |
LNKLNK.OBJ | Batch link book containing link-edit control cards used when applying maintenance with MSHP to link-edit LNKGBLS.OBJ and LNKVSE8.OBJ modules to produce ADALNK.PHASE. |
LNKLNKR.OBJ | Batch link book containing link-edit control cards used when applying maintenance with MSHP to link-edit reentrant LNKRGBL.OBJ and LNKVSER8.OBJ modules to produce ADALNKR.PHASE. |
LNKVSE8.OBJ | Batch program code object module. |
LNKVSER8.OBJ | Batch reentrant program code object module. |
To install the Adabas 8 non-reentrant link routine for z/VSE batch, complete the following steps:
Edit member LNKGBLS.A in the Adabas distribution sublibrary. Provide values for the LOGID, SVC, GBLNAME, and other keywords to suit your installation requirements. This module contains LGBLSET parameters used to create default settings for link components. A complete description of LGBLSET parameters can be found in Modifying Source Member Defaults (LGBLSET Macro) in Version 8.
Note:
The parameter OPSYS should be set to z/VSE.
Edit the ALNKLNK8.X member found in the Adabas 8 sublibrary. This member will assemble and catalog the LNKGBLS.A module and link it and any desired exits with the LNKVSE8.OBJ module to create the ADALNK.PHASE member for Adabas 8. The ALNKLNK8.X member includes sample link-edit control cards to support UES by including the LNKUES.OBJ. module with the ASC2EBC and EBC2ASC translation tables. Modify the link-edit control cards to include any additional Software AG exit or user exit, as specified in the udpated LNKGBLS.A member.
Provide the ADALNK.PHASE member in the LIBDEF search chain for the jobstep that will require Adabas database access or Software AG services.
To install the Adabas 8 reentrant link routine for z/VSE batch, complete the following steps:
Edit member LNKRGBL.A in the Adabas distribution sublibrary. Provide values for the LOGID, SVC, GBLNAME, and other keywords to suit your installation requirements. This module contains LGBLSET parameters used to create default settings for link components. A complete description of LGBLSET parameters can be found in Modifying Source Member Defaults (LGBLSET Macro) in Version 8.
Note:
The parameter OPSYS should be set to z/VSE.
Edit the ALNKLNR8.X member found in the Adabas 8 sublibrary. This member will assemble and catalog the LNKRGBL.A module and link it and any desired exits with the LNKVSER8.OBJ module to create the ADALNKR.PHASE member for Adabas 8. The ALNKLNR8.X member includes sample link-edit control cards to support UES by including the LNKUES.OBJ. module with the ASC2EBC and EBC2ASC translation tables. Modify the link-edit control cards to include any additional Software AG exit or user exit, as specified in the udpated LNKRGBL.A member.
Provide the ADALNKR.PHASE member in the LIBDEF search chain for the jobstep that will require Adabas database access or Software AG services.
Your application programs that use Adabas link routines in z/OS and VSE environments can route database calls through specific Adabas SVCs, based on the database ID used in the call. SVC routing is managed through the use of a DBID/SVC routing table you supply. Up to 1000 database IDs may be specified in the table and associated with any number of valid SVC numbers installed in the z/OS or VSE system. The DBID/SVC routing table is created using the MDBSVC macro.
Duplicate database IDs are not allowed in the DBID/SVC routing table as there is no reliable way for the link routine to determine which SVC should be used for a database ID if it is listed more than once. If duplicate database IDs are found while the table is being assembled, they are flagged with an assembler MNOTE and a return code of 16 is returned for the assembly attempt.
Notes:
Caution:
This feature should be used with caution. Transactional integrity is
not guaranteed. If an application makes calls to multiple databases that are
routed to more than one Adabas SVC, it becomes possible to issue ET, BT, OP,
CL, RC, or other Adabas commands that may affect the transaction on one
database, but not on the other databases running on different Adabas SVCs that
were accessed previously. It therefore is the responsibility of the application
program to ensure that all necessary logic is included to ensure transactional
integrity across multiple databases where multiple Adabas SVCs are employed.
This section covers the following topics:
The general steps for installing the Adabas DBID/SVC routing feature are:
Define the DBID/SVC routing table in a library member using MDBSVC macro statements. For more information about the DBID/SVC routing table and the MDBSVC macro, read Using the MDBSVC Macro.
Assemble and link-edit the DBID/SVC routing table member to create a load module or PHASE that will be made available to the operating environment where the SVC routing feature will be used.
Modify a link globals table for the operating environment, specifying the LGBLSET keywords DYNDBSVC=YES and DBSVCTN=name, where name is the name of the DBID/SVC routing table load module that should be used by the link routine. Assemble and link-edit the updated link globals table as required for the operating environment. For more information about the link globals table and the LGBLSET macro, read Modifying Source Member Defaults (LGBLSET Macro) in Version 8 . For information on assembling and link-editing the link globals table once the table is updated, refer to the instructions for each z/OS or VSE TP monitoring environment, provided elsewhere in this section.
Make the prepared DBID/SVC routing table available in a load library that is accessible by the application program's job step, so it can be loaded by the link routine when it runs.
Except for CICS systems, you will need to relink ADALNK or ADALNKR making sure that the INCLUDE statements for the LNKDSL and DEPRTR (or RTRVSE on VSE) modules are included in the job.
This section covers the following topics:
The installation steps for the Adabas SVC routing feature under z/OS batch, TSO, and IMS are the same.
To install the Adabas DBID/SVC routing feature under z/OS batch, TSO, or IMS, complete the following steps:
Define or modify the DBID/SVC routing table by coding a series of MDBCSVC macros in a library member. Sample member ADASVCTB is provided in the ADAvrs.SRCE library as a template for preparing this member. For more information about using the MDBSVC macro, read Using the MDBSVC Macro.
Assemble and link-edit the DBID/SVC routing table member to create the table as a load module that you can make available to the application execution job step. The load module should be linked non-reusable and non-reentrant because the link routine subprogram LNKDSL will need to store the addresses of the Adabas SVC IDT headers in the DBID/SVC module to reduce the operating overhead on multiple commands accessing the same Adabas SVC.
Define or modify a link globals table for the execution environment. The following LGBLSET keywords are required to support the Adabas SVC routing feature:
LGBLSET Keyword Setting | Description |
---|---|
DYNDBSVC=YES | This keyword and setting indicate that Adabas SVC routing is active for this job step. |
DBSVCTN=name | This keyword specifies the name of the DBID/SVC table for this job step. This name must match the name of the load module created to ensure the proper table is loaded when the link routine runs. |
Assemble and link-edit the updated link globals table, as described for the appropriate TP monitor. For batch/TSO, read Installing Adabas with Batch/TSO under Adabas 8; for IMS, read Installing Adabas with IMS TM under Adabas 8 .
Relink ADALNK or ADALNKR, making sure that the INCLUDE statements for the LNKDSL and DEPRTR modules are included in the job. Samples of the jobs used to relink ADALNK and ADALNKR are listed in the following table:
Link Routine | Sample Job | ||
---|---|---|---|
z/OS batch | TSO | IMS | |
ADALNK | LNKLNK8 | LNKLNK8 | --- |
ADALNKR | LNKLNKR8 | LNKLNKR8 | --- |
ADALNI8 | --- | --- | LNKLNI8 |
To install the Adabas DBID/SVC routing feature under z/VSE batch, complete the following steps:
Define or modify the DBID/SVC routing table by coding a series of MDBCSVC macros in a library member. Sample member ADASVCTB.A is provided in the sublibrary SAGLIB.ADAvrs as a template for preparing this member. For more information about using the MDBSVC macro, read Using the MDBSVC Macro.
Assemble and link-edit the DBID/SVC routing table member to create the table as a PHASE that you can make available to the application execution job step. The PHASE should be linked non-reusable and non-reentrant because the link routine subprogram LNKDSL will need to store the addresses of the Adabas SVC IDT headers in the DBID/SVC module to reduce the operating overhead on multiple commands accessing the same Adabas SVC.
Define or modify a link globals table for the execution environment. The following LGBLSET keywords are required to support the Adabas SVC routing feature:
LGBLSET Keyword Setting | Description |
---|---|
DYNDBSVC=YES | This keyword and setting indicate that Adabas SVC routing is active for this job step. |
DBSVCTN=name | This keyword specifies the name of the DBID/SVC table for this job step. This name must match the name of the PHASE created to ensure the proper table is loaded when the link routine runs. |
Assemble and link-edit the updated link globals table, as described for the appropriate TP monitor. For batch/TSO, read Installing Adabas with Batch under Adabas 8.
Relink ADALNK.PHASE or ADALNKR.PHASE, making sure that the INCLUDE statements for the LNKDSL and RTRVSE object modules are included in the job. Samples of the jobs used to relink ADALNK and ADALNKR are listed in the following table:
Link Routine | Sample Job |
---|---|
ADALNK.PHASE | ALNKLNK8.X |
ADALNKR.PHASE | ALNKLNR8.X |
To install the Adabas DBID/SVC routing feature under CICS, complete the following steps:
Define or modify the DBID/SVC routing table by coding a series of MDBCSVC macros in a library member. Sample member ADASVCTB is provided in the ADAvrs.SRCE library as a template for preparing this member. For more information about using the MDBSVC macro, read Using the MDBSVC Macro.
Assemble and link-edit the DBID/SVC routing table member to create the table as a load module and place it in a library that will be part of the CICS DFHRPL concatenation. The load module should be linked non-reusable and non-reentrant because the link routine subprogram LNKDSL will need to store the addresses of the Adabas SVC IDT headers in the DBID/SVC module to reduce the operating overhead on multiple commands accessing the same Adabas SVC.
Define the load module as a program to CICS using RDO, or the DFHCSDUP utility. See member DEFADA8 in the ACIvrs.SRCE libarary for sample DFHCSDUP definition statements. The program attributes should be Reload(No), Resident(Yes), Dataloc(Any), and Execkey(CICS).
Define or modify a link globals table for the execution environment. The following LGBLSET keywords are required to support the Adabas SVC routing feature:
LGBLSET Keyword Setting | Description |
---|---|
DYNDBSVC=YES | This keyword and setting indicate that Adabas SVC routing is active for this job step. |
DBSVCTN=name | This keyword specifies the name of the DBID/SVC table for this job step. This name must match the name of the load module created to ensure the proper table is loaded when the link routine runs. |
Assemble and link-edit the updated link globals table, as described in Installing Adabas with CICS under Adabas 8 for z/OS installations or Installing Adabas with CICS under Adabas 8 for z/VSE installations.
When the Adabas SVC routing feature is installed, as described earlier in this section, it is loaded as described below:
In batch, TSO, or IMS environments, the DBID/SVC routing table is loaded when the link routine initializes if the LGBLSET DYNDBSVC parameter is set to YES in the link globals table. The address of the routing table is kept in the link routine work area for use by all subsequent calls.
In CICS environments, the Adabas 8 initialization module ADACIC0, normally run during PLTPI processing, loads and validates the DBID/SVC routing table, if the LGBLSET DYNDBSVC parameter was set to YES in the link globals table for the CICS region. The address of the routing table is kept in the global work area associated with the Adabas 8 task-related user exit (TRUE) module, ADACICT, and is made available on each application call to the TRUE by the Adabas command-level module ADACICS/ADADCI.
When an application call is made, the DBID/SVC routing table is searched by the LNKDSL subroutine which is linked with the appropriate link routine for each operating environment. LNKDSL is called after any LUEXIT1 (link routine user exit 1) is invoked, in case the pre-Adabas call user exit modifies the command's database ID for subsequent processing. The call to LNKDSL is made before any monitoring or Adabas Fastpath exits are called, so the monitoring product, such as Adabas Review, Adabas Fastpath, or Adabas Transaction Manager, will perform their processing based on the appropriate Adabas SVC found in the DBID/SVC routing table.
If the database ID associated with a particular call is not found in the DBID/SVC routing table, the default value for the Adabas SVC as specified by the MDBSVC macro's TYPE=INIT parameter is used. If the SVC located is not an Adabas SVC, or if it is not installed on the z/OS system, an Adabas response code of 213 with subcode 16 or 20 is returned to the application. If the calling database is not active for an SVC number, an Adabas response code of 148 is returned to the application.
Duplicate database IDs are not allowed in the DBID/SVC routing table as there is no reliable way for the link routine to determine which SVC should be used for a database ID if it is listed more than once. If duplicate database IDs are found while the table is being assembled, they are flagged with an assembler MNOTE and a return code of 16 is returned for the assembly attempt.
Use the MDBSVC macro to define various aspects of the Adabas DBID/SVC routing table. Several MDBSVC macros are coded together using TYPE=INIT, TYPE=GEN, and TYPE=FINAL keywords to comprise a source module or member. This source module or member is then assembled and link-edited to build the DBID/SVC routing table load module. Sample member ADASVCTB in ADAvrs.SRCE can be used as a template for creating site-specific versions of the DBID/SVC routing table source module. Here is a sample DBID/SVC routing table source member that uses the CSECT name TESTDBT; when the table is assembled, its load module name will be TESTDBT:
TESTDBT CSECT MDBSVC TYPE=INIT,SVC=249,DBID=001 MDBSVC TYPE=GEN,SVC=237,DBID=(2,10,21,33,175,1149), X DBID2=(100,101,102,13500) MDBSVC TYPE=GEN,SVC=231,DBID=(226,899) MDBSVC TYPE=GEN,SVC=206,DBID=(15,16,69,99,500,12144) MDBSVC TYPE=GEN,SVC=248,DBID=(14,54,111,177,1213,5775) MDBSVC TYPE=GEN,SVC=249,DBID=(17,19,25,35,42,44,61,76) MDBSVC TYPE=FINAL END
When coding keyword values of MDBSVC macro statements, the assembler rules for continuing lines, identifying lists, and providing keyword values must be followed or assembly errors will result. Keywords and values with lists coded as objects of keywords must be separated by commas. There are no positional parameters used with the MDBSVC macro.
The MDBSVC macro can include the following four types of statements, as described in the following table:
The MDBSVC TYPE=INIT statement can be preceded by a named CSECT statement and named AMODE and RMODE statements. If the CSECT, AMODE, or RMODE statements are included, the name used in them must agree with the name for the DBID/SVC routing table, as coded in the TABNAME parameter on the MDBSVC TYPE=INIT statement and as specified in the DBSVCTN keyword of the LGBLSET macro used for creating the link globals table.
This section covers the following topics:
The syntax for the MDBSVC TYPE=INIT statement is:
MDBSVC TYPE=INIT [,SVC=svcno] [,DBID=dbid] [,TABNAME={name|ADBSVCT}] [,OPSYS={ZOS|VSE}]
The parameters you can code on the MDBSVC TYPE=INIT statement are described in MDBSVC Parameters.
The syntax for the MDBSVC TYPE=GEN statement is:
MDBSVC TYPE=GEN [,SVC=svcno] [,DBID=id[, id]...][,DBID2=id[, id]...]
The parameters you can code on the MDBSVC TYPE=GEN statement are described in MDBSVC Parameters.
The syntax for the MDBSVC TYPE=FINAL statement is:
MDBSVC TYPE=FINAL
No parameters are valid on the MDBSVC TYPE=FINAL statement.
The parameters that can be specified on various MDBSVC statements are as follows:
The DBID parameter can be coded on both the MDBSVC TYPE=INIT and MDBSVC TYPE=GEN statements.
When specified on the MDBSVC TYPE=INIT statement, it lists the default database ID associated with the SVC specified in the SVC parameter. In this case, only one database ID can be listed in the DBID parameter on a TYPE=INIT statement.
When specified on a MDBSVC TYPE=GEN statement, it lists the database IDs associated with the SVC specified in the SVC parameter. If more than one database ID is listed, they should be enclosed in parentheses and separated by commas.
Database IDs listed in the DBID parameter must be numeric and must correspond to the IDs of installed Adabas databases. In z/OS environments, database IDs must range from 1 to 65535. The same database ID cannot be specified on multiple MDBSVC statements; they must be unique across all of the DBID and DBID2 statements in the DBID/SVC routing table. Duplicate values are flagged with an MNOTE, which causes the assembly of the DBID/SVC routing table to stop with return code 16.
The following is an example of some DBID parameters on various MDBSVC statements. Note that two MDBSVC statements list database IDs associated with SVC 237. This allows more database IDs to be coded for the same SVC number. Compare the way this is coded to the way the same example is coded for the DBID2 parameter. Both codings produce the same end result.
MDBSVC TYPE=INIT,SVC=249,DBID=1 MDBSVC TYPE=GEN,SVC=237,DBID=(2,4,10,16,21,33) MDBSVC TYPE=GEN,SVC=237,DBID=(175,1149,1221) MDBSVC TYPE=GEN,SVC=242,DBID=(3,18) MDBSVC TYPE=FINAL END
The DBID2 parameter can be coded only on MDBSVC TYPE=GEN statements. It lists additional database IDs to be associated with an Adabas SVC specified in the SVC parameter. The DBID2 parameter is optional, but when it is specified, it must follow a DBID parameter.
Database IDs listed in the DBID2 parameter must be numeric and must correspond to the IDs of installed Adabas databases. In z/OS environments, database IDs must range from 1 to 65535. The same database ID cannot be specified on multiple MDBSVC statements; they must be unique across all of the DBID and DBID2 statements in the DBID/SVC routing table. Duplicate values are flagged with an MNOTE, which causes the assembly of the DBID/SVC routing table to stop with return code 16.
The following is an example of some MDBSVC statements that includes a DBID2 parameter. Compare the way this example is coded to the way the same example is coded for the DBID parameter. Both codings produce the same end result.
MDBSVC TYPE=INIT,SVC=249,DBID=1 MDBSVC TYPE=GEN,SVC=237,DBID=(2,4,10,16,21,33), X DBID2=(175,1149,1221) MDBSVC TYPE=GEN,SVC=242,DBID=(3,18) MDBSVC TYPE=FINAL END
The OPSYS parameter is an optional parameter that can be coded only on the MDBSVC TYPE=INIT statement. This parameter identifies the operating system where the DBID/SVC routing table is assembled. Valid values for the OPSYS parameter are "ZOS" and "VSE"; the default is "ZOS".
The PREFIX parameter can only be coded only on the MDBSVC TYPE=DSECT statement, which is reserved for internal use by Software AG. Do not use this parameter.
The SVC parameter can be coded on both the MDBSVC TYPE=INIT and MDBSVC TYPE=GEN statements.
When specified on the MDBSVC TYPE=INIT statement, it specifies the default Adabas SVC number to be used when the calling application provides a database ID that is not found in the DBID/SVC routing table.
When specified on a MDBSVC TYPE=GEN statement, it specifies the Adabas SVC number to be associated with the Adabas databases identified by the DBID and DBID2 parameters.
The SVC number listed in the SVC parameter must be numeric and must correspond to the SVC number of an installed Adabas SVC. In z/OS environments, the SVC number must range from 200 to 255. Duplicate SVC values can be coded on multiple MDBSVC statements; this allows you to code long lists of database IDs and associate them with the same Adabas SVC.
In the following example, notice that there are two MDBSVC statements for SVC 249. It is the default SVC for the link routine and is also used for database 1, 3, and 18. There are also two MDBSVC statements for SVC 237; the two statements are used to list nine databases associated with SVC 237 (2, 4, 10, 16, 21, 33, 175, 1149, and 1221).
MDBSVC TYPE=INIT,SVC=249,DBID=1 MDBSVC TYPE=GEN,SVC=237,DBID=(2,4,10,16,21,33) MDBSVC TYPE=GEN,SVC=237,DBID=(175,1149,1221) MDBSVC TYPE=GEN,SVC=249,DBID=(3,18) MDBSVC TYPE=FINAL END
The TABNAME parameter is an optional parameter that can be coded only on the MDBSVC TYPE=INIT statement. This parameter specifies the name of the DBID/SVC routing table when the source member does not include a separate (and previously coded) CSECT statement. In this case, the name you specify on the TABNAME parameter is used to generate a named CSECT statement and named AMODE and RMODE directives.
The DBID/SVC routing table name that you specify should be between 1 and 8 alphanumeric characters long. In the following example, a DBID/SVC routing table with the name TESTDBT is coded.
MDBSVC TYPE=INIT,SVC=249,DBID=1,TABNAME=TESTDBT MDBSVC TYPE=GEN,SVC=237,DBID=(2,4,10,16,21,33) MDBSVC TYPE=GEN,SVC=237,DBID=(175,1149,1221) MDBSVC TYPE=GEN,SVC=249,DBID=(3,18) MDBSVC TYPE=FINAL END
The Adabas 8 LGBLSET macro is used to set default installation values for the Adabas link routines. It is used to prepare an object module which may either be link-edited with the Adabas 8 link routines or provided to the link routines in the job step where they are run. Your Adabas libraries include sample members provided to support the various teleprocessing (TP) monitors in each environment. Each of these sample members may be copied to an appropriate library and modified to provide the necessary customization required for the link routine that is intended to run in a given environment.
The LGBLSET parameter options with their default values (underlined) are described in the rest of this section:
LUINFO: Length of User Data passed to Adabas LUEXIT1 and LUEXIT2
LUSAVE: Size of User Save Area for Adabas LUEXIT1 and LUEXIT2
Parameter | Description | Syntax |
---|---|---|
ADL |
Indicates whether or not the Consistency Interface of Software AG’s Adabas Bridge for DL/I is to be supported by this command-level link routine.
|
ADL={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
AVB |
Indicates whether or not Software AG’s Adabas Bridge for VSAM is to be supported by this command-level link routine.
|
AVB={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
CITSNM |
Specifies the 16-byte string that represents the CICS TS queue name for Adabas. The default is "ADACICS". |
CITSNM={ADACICS|qname} |
Parameter | Description | Syntax |
---|---|---|
COR |
Indicates whether or not Adabas System Coordinator (SYSCOR), Adabas Transaction Manager, and Adabas Fastpath exits are installed and active.
|
COR={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
DBSVCTN |
Provides the name of the DBID/SVC routing table that should be used by the link routine during its execution, if any. The routing table name must conform to names for z/OS standard load modules. It is used by a z/OS LOAD macro/SVC during batch, TSO, or IMS operation or by an EXEC CICS LOAD PROGRAM command during CICS operation. If the load module listed is not found, or if it is found to contain invalid header information, user abend U657 is issued in batch, TSO, or IMS environments. If the load module is not defined to CICS or not found in the CICS DFHRPL concatenation, the Adabas CICS link routine environment is not initialized. Note: For more information about SVC routing by database ID in z/OS environments, read Establishing Adabas SVC Routing by Adabas Database ID. Note: |
DBSVCTN={name|ADASVCTB} |
Parameter | Description | Syntax |
---|---|---|
DYNDBSVC |
Indicates whether Adabas SVC routing by database ID should be enabled for the link routine. DYNDBSVC=YES enables Adabas SVC routing by database ID; DYNDBSVC disables it. The default is NO. For more information about SVC routing by database ID in z/OS environments, read Establishing Adabas SVC Routing by Adabas Database ID. |
DYNDBSVC={YES|NO} |
Parameter | Description | Syntax |
---|---|---|
ENTPT |
The name given to the Adabas CICS command-level link routine. This name is used in EXEC CICS LINK commands to invoke Adabas services from CICS application programs. See also notes 1 and 2 in the installation procedure. |
ENTPT={ADACICS|name} |
Parameter | Description | Syntax |
---|---|---|
GBLNAME |
The name of the link globals module. |
GBLNAME={LNKGBLS|name} |
Parameter | Description | Syntax |
---|---|---|
GEN |
Indicates whether a CSECT or DSECT is generated. |
GEN={CSECT|DSECT} |
Parameter | Description | Syntax |
---|---|---|
IDTNAME |
The common memory pool name of the BS2000 IDT. |
IDTNAME=name |
Parameter | Description | Syntax |
---|---|---|
IDTUGRP |
Indicates whether the common memory pool is user bound (BS2000) |
IDTUGRP={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
LOGID |
The value of the default target database ID. Valid ID numbers are 1-65535. The default is "1". |
LOGID={nnn | 1} |
Parameter | Description | Syntax |
---|---|---|
LUINFO |
The length of the user data to be passed to target user exit 4. Valid values are numbers from zero (0) through 32,767. If LUINFO is not specified, the default is zero (no user data is passed). |
LUINFO={0|length} |
Parameter | Description | Syntax |
---|---|---|
LUSAVE |
The size of the user save area to be used by Adabas user exits LUEXIT1 and LUEXIT2. Valid values range from zero (0) through 256. The default is "72". If LUSAVE is not specified, the default is zero (no user save area is passed). |
LUSAVE={72|size} |
Parameter | Description | Syntax |
---|---|---|
LX1NAME |
The name of the link user exit 1 module |
LX1NAME={LUEXIT1|name} |
Parameter | Description | Syntax |
---|---|---|
LX2NAME |
The name of the link user exit 2 module |
LX2NAME={LUEXIT2|name} |
Parameter | Description | Syntax |
---|---|---|
MRO |
Indicates whether or not the CICS multiple region option (MRO) support is required. If you run the CICS command-level link with the CICS MRO, set this to MRO=YES; otherwise, use the default value MRO=NO. If MRO=YES, NETOPT must be set to NETOPT=NO (the default) to prevent non-unique LU names from multiple application regions. If NETOPT=YES and MRO=YES are specified, an assembler MNOTE and a return code of 16 are produced from the assembly step. |
MRO={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
NETOPT |
If NETOPT=YES is specified, an 8-byte user ID will be constructed from the VTAM LU name. If NETOPT=NO is specified, the user ID is created from the constant CICS plus the four-byte CICS terminal ID (TCTTETI) for terminal tasks. For non-terminal tasks, the user ID comprises the constant CIC plus the CICS task number. If you run with the CICS multiple region option (MRO), you must use the default value for this option. If NETOPT=YES and MRO=YES are specified, an assembler MNOTE and a return code of 16 are produced from the assembly step. |
NETOPT={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
NTGPID |
Specifies a four-byte Natural group ID as required for unique Adabas user ID generation in the CICSplex environment with Natural Version 2.2.8 and above. The value is associated with all users who call the Adabas command-level link routine assembled with the specified value. There is no default value. If no value is specified, the Adabas internal user ID is built in the conventional manner. Any four-byte alphanumeric value may be specified, but it must be unique for each Adabas command-level link routine running in a CICSplex, or z/OS image. If more than one NTGPID is required (for example, both test and production Natural 2.2.8), more than one Adabas command-level link routine with associated TRUE must be generated. If you run with the CICS multiple region option (MRO), you may use NTGPID to provide a 4-byte literal for the Adabas communication ID to be used by the Adabas SVC when multiple application regions call Adabas. |
NTGPID=4-byte-value |
Parameter | Description | Syntax |
---|---|---|
NUBS |
The number of user blocks (UBs) to be created in the user block pool by the CICS link routine. The number of blocks must be large enough to handle the maximum possible number of concurrent Adabas requests. Note: |
NUBS={100|blocks} |
Parameter | Description | Syntax |
---|---|---|
OPSYS |
The operating system in use. |
OPSYS={ZOS|VSE|CMS|BS2} |
Parameter | Description | Syntax |
---|---|---|
PARMTYP |
The CICS area which is to contain the Adabas parameter list. "TWA" picks up the parameter list in the first six fullwords of the transaction work area (TWA). When PARMTYP=COM, the Adabas parameters are supplied in the CICS COMMAREA provided by the calling program with the EXEC CICS LINK command. The COMMAREA list for an ACB call must be at least 32 bytes long and begin with the label "ADABAS52". The COMMAREA list for an ACBX call must be at least 24 bytes long and begin with the label "ADABAS8X". In addition, the last ABD in the COMMAREA list for an ACBX call must be indicated by setting the VL-bit -- in other words, the high bit in the address must be on (X'80'). PARMTYP=ALL (the default) uses both the COMMAREA and TWA to pass the Adabas parameters; in this case, the COMMAREA is checked first. We do not recommend that you attempt to map the CICS TWA to the Adabas 8 ACBX direct call. This is because the TWA is of finite size per transaction and because the TWA in not available at CICS startup. We therefore recommend that CICS programs using the Adabas 8 CICS link routines use the COMMAREA only for passing data. |
PARMTYP={ALL|COM |TWA} |
Parameter | Description | Syntax |
---|---|---|
PRE |
The two-byte string to be used as the DSECT data prefix. The default is "LG". |
PRE={LG|prefix} |
Parameter | Description | Syntax |
---|---|---|
PURGE |
The PURGE parameter is used when assembling with CICS 3.2 or above. If PURGE=YES is specified, the CICS WAIT EXTERNAL will contain PURGEABLE as one of its parameters, allowing the transaction to be purged by CICS if the DTIMOUT value is exceeded and PURGE is specified. If PURGE=NO (the default) is specified, the NONPURGEABLE option is generated. |
PURGE={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
RENT |
Indicates whether the globals module is reentrant. |
RENT={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
RETRYX |
Indicates whether the retry command exit is active. |
RETRYX={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
REVIEW |
Indicates whether or not Software AG’s Adabas Review performance monitor is installed and active. When REVIEW=YES is specified, a work area of 512 bytes is set up for use by Adabas Review. |
REVIEW={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
RMI |
The RMI parameter is used to indicate whether or not the CICS Resource Manager Interface is in use. If RMI=YES is specified, the Adabas task-related user exit (TRUE) will be executed as a resource manager (RM) using the CICS Resource Manager Interface (RMI). RMI=YES is valid only when the Adabas Transaction Manager is installed, enabled, and available to users executing in the CICS environment. Consult the Adabas Transaction Manager documentation for additional instructions related to the installation of the Adabas TRUE. |
RMI={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
RTXNAME |
The name of the command retry exit module. |
RTXNAME={LUEXRTR|name} |
Parameter | Description | Syntax |
---|---|---|
SAF |
Indicates whether Software AG's Adabas SAF Security support is required. |
SAF={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
SAP |
Indicates whether or not SAP user ID generation is supported. If SAP=YES is specified, the program will detect a SAP initialization call and set the user ID for SAP applications from the constant provided on the initialization call, plus the field ACBADD2. For more information, refer to the supplementary information provided to customers using the SAP application system. |
SAP={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
SAPSTR |
The four-byte SAP ID string to use. |
SAPSTR={'SAP*'|string} |
Parameter | Description | Syntax |
---|---|---|
SVCNO |
The value of the Adabas SVC number. On z/OS systems, valid values range from 200-255 and the default is "249". On z/VSE systems, valid values range from 32-128 and the default is "45". |
SVCNO=nnn |
Parameter | Description | Syntax | ||
---|---|---|---|---|
TPMON |
The TP monitor operating environment. Valid values should be specified as follows:
|
TPMON={BAT|CICS|COM|IMS} |
Parameter | Description | Syntax |
---|---|---|
TRUENM |
Specifies the module name of the Adabas CICS task-related user exit (TRUE). The default is ADACICT. |
TRUENM={ADACICT|name} |
Parameter | Description | Syntax |
---|---|---|
UBPLOC |
Specifies whether the user block (UB) pool is to be obtained above (the default) or below the 16-megabyte line in CICS. The ECB used by the EXEC CICS WAIT WAITCICS or the EXEC CICS WAIT EXTERNAL is included in the UB pool. The UBPLOC=BELOW setting supports versions of CICS that do not allow ECBs above the 16-megabyte line; that is, CICS/ESA 3.2 or below. Refer to the IBM manual CICS Application Programming Reference for more information. |
UBPLOC={ABOVE|BELOW} |
Parameter | Description | Syntax |
---|---|---|
UES |
Indicates whether or not Universal Encoding Support (UES) is required. |
UES={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
USERX1 |
Indicates whether or not user exit 1 is active. |
USERX1={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
USERX2 |
Indicates whether or not user exit 2 is active. |
USERX2={NO|YES} |
Parameter | Description | Syntax |
---|---|---|
XWAIT |
Indicates whether a standard EXEC CICS WAITCICS (XWAIT=NO) or a WAIT EVENTS EXTERNAL (XWAIT=YES) will be executed by the Adabas 8 task-related user exit (TRUE). XWAIT=YES is the default. The CICS WAIT EVENTS EXTERNAL (XWAIT=YES) is the recommended interface for CICS/TS 1.1 and above. The CICS WAITCICS statement (XWAIT=NO) is provided for use with CICS/MVS 2.1.2 and for CICS/VSE 2.1 through 2.3. It may also be used for CICS/TS 1.1 and above, but may result in poor CICS transaction performance or unpredictable transaction results in busy CICS environments. Note: |
XWAIT={NO|YES} |
Notes:
CICS WAITCICS (XWAIT=NO) can support a soft post of the specified ECB. This has the disadvantage of becoming a low priority dispatchable unit of work in a CICS environment, since the hand-postable work is not processed by CICS on every work cycle.
EXEC CICS WAIT EXTERNAL (XWAIT=YES), on the other hand, allows CICS to make use of its special post exit code, and will always be checked and processed (if posted) on every CICS work cycle.
For more details on the differences between the various CICS WAIT commands and their relationship to hard and soft posting mechanisms, consult the IBM CICS Application Programming Reference and the texts accompanying IBM APAR PN39579 or “Item RTA000043874” on the IBM InfoLink service.
The Adabas SVC is fully compatible with the XWAIT=YES setting. The SVC performs the necessary hard post for Adabas callers under CICS using the Adabas command-level link routine. The same SVC performs a soft post for batch callers where the hard post is not required.