The NETSIP/NETSIR initialization program messages are:
NETS000 | NETS001 | NETS002 | NETS003 | NETS004 | NETS005 | NETS006 | NETS007 | NETS008 | NETS010 | NETS011 | NETS012 | NETS013 | NETS014 | NETS015 | NETS017 | NETS018 | NETS019 | NETS020 | NETS021 | NETS022 | NETS023 | NETS024 | NETS025 | NETS026 | NETS027 | NETS028 | NETS029 | NETS030 | NETS031 | NETS032 | NETS033 | NETS034 | NETS038 | NETS039 | NETS040 | NETS041 | NETS042 | NETS043 | NETS044 | NETS045 | NETS050 | NETS051 | NETS052 | NETS500 | NETS501 | NETS502 | NETS503 | NETS504 | NETS505 | NETS507 | NETS508 | NETS509 | NETS510 | NETS511 | NETS512 | NETS513 | NETS514 | NETS515 | NETS516 | NETS517 | NETS518 | NETS519 | NETS520 | NETS521 | NETS522 | NETS523 | NETS524 | NETS525 | NETS526 | NETS527 | NETS528 | NETS529 | NETS530 | NETS531 | NETS532 | NETS533 | NETS534 | NETS535 | NETS536 | NETS537 | NETS538 | NETS539 | NETS598 | NETS599 | NETS600 | NETS601 | NETS602 | NETS603 | NETS604 | NETS605 | NETS606 | NETS607 | NETS608 | NETS609 | NETS610 | NETS611 | NETS612 | NETS613 | NETS614 | NETS615 | NETS616 | NETS617 | NETS618 | NETS619 | NETS620 | NETS621 | NETS622 | NETS623 | NETS624 | NETS625 | NETS626 | NETS627 | NETS628 | NETS629 | NETS630 | NETS640 | NETS641 | NETS642 | NETS643 | NETS644 | NETS650
NETS000 | Entire Net-Work V5 VSE SIP STARTED SIP IS RUNNING UNDER VSE/systype-mode (yyyy-mm-dd, SM=xxx, ZAP=xxxx) SIP IS RUNNING UNDER OSYS LEVEL Vvvv |
Explanation |
z/VSE: The NETSIP program has started. systype is the z/VSE operating system type and 'mode' is the ECPS (EMODE), z/VM, or 370 operating mode. |
System Action |
NETSIP continues execution. |
User Action |
None required. This message is informational only. |
NETS001 | SUBSID MACRO ERROR |
Explanation |
The z/VSE operating system release is too low for installing Entire Net-Work. NETSIP received a non-zero return code from the operating system. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Refer to the section Supported Operating System Levels in the Entire Net-Work Release Notes. |
NETS002 | UNSUPPORTED VSE RELEASE BASED UPON SUBSID |
Explanation |
z/VSE: A NETSIP validation check indicates an unsupported operating system level. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
The z/VSE operating system release is too low for installing Entire Net-Work. Refer to the section Supported Operating System Levels in the Entire Net-Work Release Notes. |
NETS003 | VSE SYSTEM NOT RUNNING UNDER VM |
Explanation |
z/VSE: The operating system is not running in a virtual machine in the z/VM environment. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Run the z/VSE system under z/VM, or use a line driver that is not dependent on z/VM. |
NETS004 | NETSIP NOT RUNNING IN A VIRTUAL PARTITION |
Explanation |
z/VSE: NETSIP is executing in a 'V=R' partition. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Execute NETSIP in a 'V=V' partition. |
NETS005 | NO SYSPARM VALUE SPECIFIED FOR SVC |
Explanation |
z/VSE: NETSIP could not find a SYSPARM input, and the specified SVC has not been 'zapped'. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Either provide the SVC with SYSPARM, or zap the specified SVC with NETSIP. |
NETS006 | DEFAULT VALUE USED FOR THE SVC |
Explanation |
z/VSE: No SYSPARM SVC has been used. This message is informational only. |
System Action |
NETSIP continues execution, no error has occurred. |
User Action |
NETSIP defaults to use of the zapped SVC. |
NETS007 | NON-NUMERIC DATA FOUND IN SYSPARM FIELD |
Explanation |
z/VSE: Either SYSPARM or the default NETSIP SVC contains a non-numeric value. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Correct the specified SYSPARM value, or set the default SVC value to 31. |
NETS008 | INVALID RANGE SPECIFIED FOR THE SVC 30-256 |
Explanation |
z/VSE: NETSIP found an SVC less than 30 or greater than 256 in SYSPARM or the NETSIP default SVC. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Set the SVC to a value within the range 30-256. |
NETS010 | NETSVCxx WAS NOT FOUND IN THE SVA |
Explanation |
z/VSE: While performing a z/VSE load, NETSIP found that the specified level NETSVC was not in the SVA. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Relink the Entire Net-Work SVC with SVA using the z/VSE 'PHASE' statement, or do the SET SDL for NETSVCxx (z/VSE). |
NETS011 | NO MATCH ON ID - INCORRECT NETSVC LOADED |
Explanation |
z/VSE: NETSIP found an incorrect SVC version while trying to do a load operation. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Relink NETSVCV5 with the correct Version 5 SVC module. |
NETS012 | SVC TABLE ENTRY WAS FOUND TO BE INVALID |
Explanation |
z/VSE: The SVC number provided by SYSPARM is either not valid, or does not represent either the old or new version of the z/VSE Entire Net-Work SVC. This error can occur if the UPSI statement's 'C' parameter specified '1'. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Respecify the UPSI statement, or specify another unused SVC value. Rerun NETSIP. |
NETS013 | NETSIP HAS ALREADY RUN BEFORE |
Explanation |
z/VSE: NETSIP found that the same program is being run again. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
The SVC is not installed. To reinstall the same SVC, you must first perform a SET SDL. |
NETS014 | NON-ZERO RETURN CODE FROM NETSVC |
Explanation |
z/VSE: The initial invocation of the Entire Net-Work SVC completed abnormally. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Verify that the correct version of the SVC has been loaded into the SVA, then rerun NETSIP. |
NETS015 | CPIT TABLE NOT FOUND IN SVA |
Explanation |
z/VSE: A request was made for NETSIP to snap the Entire Net-Work areas but the cross-product interface table could not be located in the SVA. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Correct this problem by making sure that there is a SET SDL done for the CPIT (XPR$CPIT). |
NETS017 | SVC TABLE CANNOT BE LISTED UNDER MVS/ESA |
Explanation |
z/VSE: The NETSIP program does not support the listing of the z/VSE SVCTAB for the operating system z/VSE/MVT. |
System Action |
NETSIP puts out this message and terminates prematurely. |
User Action |
Consult the z/VSE/MVT manual to install a user SVC. |
NETS018 | INVALID KEYWORD WAS FOUND IN THE PARM FIELD |
Explanation |
z/VSE: The parameter field specified on the z/VSE EXEC statement contained a keyword that was not recognized. |
System Action |
NETSIP puts out this message and terminates prematurely. |
User Action |
Correct the parameter value and rerun NETSIP. |
NETS019 | NON NUMERIC DATA FOUND IN THE QSIZE FIELD |
Explanation |
z/VSE: The value for the QSIZE parameter was not numeric. |
System Action |
NETSIP puts out this message and terminates prematurely. |
User Action |
Correct the parameter value and rerun NETSIP. |
NETS020 | INVALID LENGTH FOR THE RESID FIELD |
Explanation |
z/VSE: The value for the RESID parameter was longer than eight characters. |
System Action |
NETSIP puts out this message and terminates prematurely. |
User Action |
Correct the parameter value and rerun NETSIP. |
NETS021 | NON ZERO RETURN CODE FROM IUCV QUERY |
Explanation |
z/VSE: The program NETSIP has detected a non zero condition from the IUCV query for max. connections. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS022 | UNABLE TO HOOK EXTERNAL FLIH |
Explanation |
z/VSE: The program NETSIP was unable to locate from the existing external FLIH the address of the savearea used by that FLIH. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS023 | UNABLE TO ACQUIRE COMMON STORAGE VIA GETVIS |
Explanation |
z/VSE: The program NETSIP was unable to acquire GETVIS storage in the SVA for the necessary control blocks. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Increase the size of real GETVIS storage in the SVA and IPL the z/VSE system. |
NETS024 | IUCV ERROR DURING CONNECT FUNCTION |
Explanation |
z/VSE: The program NETSIP detected a non zero return code from the dummy IUCV connect to determine MSGLIMIT. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS025 | UNABLE TO ACQUIRE INTQ STORAGE VIA GETVIS |
Explanation |
z/VSE: The program NETSIP could not acquire storage in the SVA for either the Entire Net-Work 5 interrupt queue or the path table. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Increase the size of real GETVIS storage in the SVA and IPL the z/VSE system. |
NETS026 | STXIT AB HAS BEEN ENTERED IN NETINIT |
Explanation |
z/VSE: The NETSIP abend handler has been entered while running this utility. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS027 | NON ZERO RETURN CODE FROM SEVER |
Explanation |
z/VSE: The program NETSIP has detected a non zero return from the IUCV sever function. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS028 | IUCV PRODUCT ENTRY NOT IN CPIT |
Explanation |
z/VSE: The program NETSIP has detected that it could not find a IUCV product entry in the CPIT in the SVA (XPR$CPIT). |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS029 | DECLARE BUFFER ALREADY DONE |
Explanation |
z/VSE: The program NETSIP has detected that another program has previously done an IUCV declare buffer and the program NETSIP cannot find the necessary entries in the CPIT to obtain the address of the external buffer. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS030 | NO FREE SLOTS IN CPIT |
Explanation |
z/VSE: The Cross Product Interface Table is full. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS031 | LOAD FAILED FOR XPR$CPIT |
Explanation |
z/VSE: The program NETSIP detected a non zero return code from the z/VSE load macro for the CPIT table (XPR$CPIT). |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Check that you have done a SET SDL for the phase XPR$CPIT into the SVA. |
NETS032 | XPR$CPIT NOT IN SVA |
Explanation |
z/VSE: The program NETSIP has detected via the z/VSE load macro that the phase XPR$CPIT was found but not in the SVA. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Check that you have done a SET SDL for the phase XPR$CPIT into the SVA. |
NETS033 | XPR$CPIT NOT IN SDL |
Explanation |
z/VSE: The program NETSIP has detected in scanning the SVA SDL that the phase XPR$CPIT was not found. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Check that you have done a SET SDL for the phase XPR$CPIT into the SVA. |
NETS034 | INITIALIZATION LOGIC ERROR DETECTED |
Explanation |
z/VSE: The program NETSIP has detected that it is running with a z/VM generated supervisor, however, the 370 support module has received control. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Contact your Software AG technical support representative. |
NETS038 | NETSVCxx IS RMODE=ANY |
Explanation |
z/VSE: NETSVC has been link-edited incorrectly, i.e., with RMODE=ANY. |
System Action |
NETSIP backs out any modifications to the system and terminates prematurely. |
User Action |
Refer to the sample link-edit JCS LINKIUCV.X to correctly link edit NETSVC with RMODE=24. |
NETS039 | NETSIP IS AMODE=31 |
Explanation |
z/VSE: NETSIP has detected a 31-bit addressing capability and has switched to AMODE=31. This is an informational message that appears only on z/VSE Version 2.6 or above. |
System Action |
None. |
User Action |
None. |
NETS040 | NETSVCxx svcnumb INSTALLED |
Explanation |
z/VSE: NETSIP has installed Version 5 SVC 'svcnumb successfully. |
System Action |
NETSIP terminates normally. |
User Action |
None required. This message is informational only. |
NETS041 | NETSIP TERMINATED ABNORMALLY |
Explanation |
z/VSE: NETSIP was stopped by an unrecoverable error. This message is accompanied by other messages describing the problem. |
System Action |
NETSIP has encountered an error and backed out all modifications made to the system. |
User Action |
Refer to the 'action' descriptions in the accompanying messages. |
NETS042 | xxxxxx = SVC ADDRESS |
Explanation |
z/VSE: This is an informational message that provides the SVC address of NETSVC. |
System Action |
None. |
User Action |
None. |
NETS043 | xxxxxx = COMMON AREA ADDRESS |
Explanation |
z/VSE: This is an informational message that provides the common area address. In z/VM mode, this message is meaningless and does not appear. |
System Action |
None. |
User Action |
None. |
NETS044 | xxxxxx = INTERRUPT QUEUE ADDRESS |
Explanation |
z/VSE: This is an informational message that provides the interrupt queue address. In z/VM mode, this message is meaningless and does not appear. |
System Action |
None. |
User Action |
None. |
NETS045 | xxxxxx = PATH TABLE ADDRESS |
Explanation |
z/VSE: This is an informational message that provides the path table address. In z/VM mode, this message is meaningless and does not appear. |
System Action |
None. |
User Action |
None. |
NETS050 | AREAS HAVE BEEN SNAPPED TO SYSLST |
Explanation |
z/VSE: The NETSIP program has snapped certain areas based upon the user setting the upsi 80 byte and these areas have now been snapped to SYSLST. |
System Action |
NETSIP terminates normally after the printing the data. |
User Action |
None required. This message is informational only. |
NETS051 | VSE SVC nnnn is xxxxxx | ||||
Explanation |
z/VSE: The program NETSIP lists the z/VSE SVCTAB indicating used and unused SVCs. |
||||
System Action |
This is an informational message and no further action is taken. |
||||
User Action |
The user can select an unused SVC for the Entire Net-Work z/VSE SVC:
|
NETS052 | VSE SVC TABLE AUDIT COMPLETED |
Explanation |
z/VSE: The program NETSIP has completed the listing of the z/VSE SVCTAB. |
System Action |
This is an informational message and no further action is taken. |
User Action |
None required. This message is informational only. |
NETS500 | Entire Net-Work 5 INSTALLATION PROGRAM NETSIP (yyyy-mm-dd, SM=sm, ZAP=zap) OPERATING SYSTEM ===> sys |
Explanation |
MVS: The message indicates that NETSIP has started execution. The system maintenance and zap levels are displayed and the operating system environment (MVS/SP, MVS/XA or MVS/ESA) |
System Action |
NETSIP continues execution. |
User Action |
None required. This message is informational only. |
NETS501 | ERROR(S) DETECTED IN EXTRACT PROCESSING: I=> parm-string |
Explanation |
MVS: The parameter extraction process has encountered a string that could not be parsed. |
System Action |
The parameter string in error is displayed with the error string underscored. NETSIP terminates abnormally with a dump. |
User Action |
Correct the parameter string and rerun the job. |
NETS502 | ERROR(S) DETECTED IN VALIDATE PROCESSING: |
Explanation |
MVS: The parameter validation process has encountered an invalid parameter value. |
System Action |
This message is followed by one of the messages NETS503 through NETS514 which supplies further information. NETSIP terminates abnormally with a dump. |
User Action |
Correct the parameter value and rerun the job. |
NETS503 | KEYWORD=CONSID, VALUE=consid |
Explanation |
MVS: The value 'consid' is invalid for the CONSID parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the CONSID parameter value and rerun the job. |
NETS504 | KEYWORD=CSTORAGE, VALUE=cstorage |
Explanation |
MVS: The value 'cstorage' is invalid for the CSTORAGE parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the CSTORAGE parameter value and rerun the job. |
NETS505 | KEYWORD=CSUBSYS, VALUE=csubsys |
Explanation |
MVS: The value 'csubsys' is invalid for the CSUBSYS parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the CSUBSYS parameter value and rerun the job. |
NETS507 | KEYWORD=LEAVE, VALUE=leave |
Explanation |
MVS:The value 'leave' is invalid for the LEAVE parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the LEAVE parameter value and rerun the job. |
NETS508 | KEYWORD=NSUBSYS, VALUE=nsubsys |
Explanation |
MVS: The value 'nsubsys' is invalid for the NSUBSYS parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the NSUBSYS parameter value and rerun the job. |
NETS509 | KEYWORD=PSTORAGE, VALUE=pstorage |
Explanation |
MVS: The value 'pstorage' is invalid for the PSTORAGE parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the PSTORAGE parameter value and rerun the job. |
NETS510 | KEYWORD=QSIZE, VALUE=qsize |
Explanation |
MVS: The value 'qsize' is invalid for the QSIZE parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the QSIZE parameter value and rerun the job. |
NETS511 | KEYWORD=REPLACE, VALUE=replace |
Explanation |
MVS: The value 'replace' is invalid for the RESTORE parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the RESTORE parameter value and rerun the job. |
NETS512 | KEYWORD=SNAP, VALUE=snap |
Explanation |
MVS: The value 'snap' is invalid for the SNAP parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the SNAP parameter value and rerun the job. |
NETS513 | KEYWORD=SVCNR, VALUE=svcnr |
Explanation |
MVS: The value 'svcnr' is invalid for the SVCNR parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the SVCNR parameter value and rerun the job. |
NETS514 | KEYWORD=SVCTAB, VALUE=svctab |
Explanation |
MVS: The value 'svctab' is invalid for the SVCTAB parameter. |
System Action |
This message is preceded by the message NETS502. NETSIP terminates abnormally with a dump. |
User Action |
Correct the SVCTAB parameter value and rerun the job. |
NETS515 | INVALID OPERATING SYSTEM DETECTED - NOT MVS |
Explanation |
MVS: An attempt was made to execute the MVS version of NETSIP in an environment other than MVS. |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Execute the version of NETSIP which matches your system or upgrade your system to a supported level of MVS. |
NETS516 | EXECUTE PARAMETER LENGTH GREATER THAN MAXIMUM (68) |
Explanation |
MVS: A parameter value longer than 68 bytes was encountered. |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Correct the NETSIP parameters. |
NETS517 | CATASTROPHIC CONDITION OCCURRED IN EXTRACT |
Explanation |
MVS: An unexpected delimiter value was encountered during parameter paring. |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Correct the NETSIP parameters. |
NETS518 | TERMINAL ERROR(S) DETECTED IN PARAMETER PROCESSING |
Explanation |
MVS: A parameter error was encountered. |
System Action |
This message is preceded by messages which explain the error in detail. |
User Action |
Correct the NETSIP parameters. |
NETS519 | PROGRAM ADDRESSING MODE INCORRECT (NOT AMODE=31) |
Explanation |
MVS: In an MVS/XA or MVS/ESA environment one or more of the programs NETSIR, NETFLIH or NETSVC was link edited to run with addressing mode 24. |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Check the addressing mode of the programs and relink with AMODE 31. |
NETS520 | PROGRAM RESIDENCY MODE INCORRECT (NOT RMODE=24) |
Explanation |
MVS: In an MVS/XA or MVS/ESA environment one or more of the programs NETSIR, NETFLIH or NETSVC was linked to run with residency mode ANY. |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Check the residency mode of the programs and relink with RMODE 24. |
NETS521 | PROGRAM NOT APF AUTHORIZED |
Explanation |
MVS: NETSIP was not loaded from an APF Authorized library, an unauthorized library was contained in the STEPLIB concatenation or NETSIP was not link edited with SETCODE AC(1). |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Check the APF status of the load library and if necessary relink NETSIP SETCADE AC(1). |
NETS522 | OPERATING SYSTEM IS NOT A VIRTUAL MACHINE GUEST |
Explanation |
MVS: The MVS system NETSIP is executing on is not running under z/VM. |
System Action |
NETSIP terminates abnormally with a dump. |
User Action |
Chose another access method suited to physical environments such as VTAM or Channel-to-Channel. |
NETS523 | LOAD FAILURE FOR PROGRAM - pgmname |
Explanation |
MVS: The program 'pgmname' could not be loaded. |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Check the library definition for the program in the execution JCL. |
NETS524 | ACRONYM CHECK FAILURE FOR PROGRAM - pgmname |
Explanation |
MVS: NETSIP encountered an incorrect version the program 'pgmname . |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Verify that the correct version of this program is in the load library. |
NETS525 | RECOVERY ENVIRONMENT CREATION FAILURE (ESTAE) |
Explanation |
MVS: NETSIP was unable to establish an error recovery routine. |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS526 | CPIT SUBSYSTEM FOR CROSS PRODUCT INTERFACE TABLE |
Explanation |
MVS: The Cross Product Interface Table SSCVT already installed. |
System Action |
NETSIP continues processing if the REPLACE parameter was specified, otherwise NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
None required. This message is informational only. verify that NETSIP is to be rerun and specify the REPLACE parameter. |
NETS527 | CPIT SUBSYSTEM FOR CROSS PRODUCT INTERFACE INSTALLED |
Explanation |
MVS: The Cross Product Interface Table SSCVT has been successfully installed. |
System Action |
NETSIP continues processing. |
User Action |
None required. This message is informational only. |
NETS528 | subs SUBSYSTEM INITIALIZATION FAILURE |
Explanation |
MVS: The subsystem 'subs' could not be added to the SSCVT chain. |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS529 | subs SUBSYSTEM HAS BEEN REMOVED |
Explanation |
MVS: The subsystem 'subs' was removed from the SSCVT chain during error recovery |
System Action |
NETSIP continues with error recovery. |
User Action |
Correct the problem which caused the original error. |
NETS530 | SVCTABLE UPDATE FAILURE - SVC NUMBER XXX |
Explanation |
MVS: NETSIP could not modify the MVS SVCTABLE to suit the Entire Net-Work SVC. |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS531 | OPEN/BLDL FAILURE - DDNAME=libname |
Explanation |
MVS: NETSIP could not open or build a directory for the library libname. |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Check the DDNAME in the JCL. |
NETS532 | GETMAIN FAILURE - S=sbp, L=length(D) |
Explanation |
MVS: NETSIP could not allocate required storage in the length of 'length' in the subpool 'sbp' . |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Verify that the subpool has sufficient storage and that the REGION parameter is set high enough. |
NETS533 | FREEMAIN FAILURE - S=sbp, L=length(D), A=address(H) |
Explanation |
MVS: NETSIP could not free allocated storage at location 'address' in the length of 'length' in the subpool 'sbp . |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Contact the local Entire Net-Work support personnel. |
NETS534 | Entire Net-Work 5 SUBSYSTEM HAS BEEN INSTALLED |
Explanation |
MVS: The Entire Net-Work SSCVT has been successfully installed. |
System Action |
NETSIP continues processing. |
User Action |
None required. This message is informational only. |
NETS535 | Entire Net-Work 5 SUBSYSTEM IS ALREADY INSTALLED |
Explanation |
MVS: An Entire Net-Work SSCVT was encountered and the REPLACE parameter was not specified. |
System Action |
NETSIP backs out any modifications to the system and terminates with a dump. |
User Action |
Check if the Entire Net-Work environment has been successfully installed and specify the REPLACE parameter if not. |
NETS536 | Entire Net-Work 5 SUBSYSTEM HAS BEEN REMOVED |
Explanation |
MVS: An Entire Net-Work SSCVT was removed from the SSCVT chain during error recovery. |
System Action |
NETSIP continues with error recovery. |
User Action |
Correct the problem which caused the original error. |
NETS537 | Entire Net-Work 5 SVC svcno HAS BEEN INSTALLED |
Explanation |
MVS: The Entire Net-Work SVC has been successfully installed as SVC number 'svcno . |
System Action |
NETSIP continues processing. |
NETS538 | Entire Net-Work 5 SVC HAS BEEN REMOVED FROM THE SYSTEM |
Explanation |
MVS: An Entire Net-Work SVC was removed from the system SVCTABLE during error recovery |
System Action |
NETSIP continues with error recovery. |
User Action |
Correct the problem which caused the original error. |
NETS539 | Entire Net-Work 5 SVC COULD NOT BE REMOVED FROM THE SYSTEM |
Explanation |
MVS: An Entire Net-Work SVC could not be removed from the system SVCTABLE during error recovery |
System Action |
NETSIP continues with error recovery. |
User Action |
Correct the problem which caused the original error and specify the REPLACE parameter. |
NETS598 | NETSIP - NETSIR INITIALIZATION FAILED |
Explanation |
MVS: NETSIP has encountered errors during execution. |
System Action |
NETSIP terminates abnormally with a dump. Other error messages precede this message. |
User Action |
Refer to the error message and correct the error. |
NETS599 | NETSIP - NORMAL TERMINATION |
Explanation |
MVS: The Entire Net-Work environment has been successfully initialized. |
System Action |
NETSIP terminates normally. |
User Action |
None required. This message is informational only. |
NETS600 | NETSIR (yyyy-mm-dd, SM=sm, ZAP=zap) |
Explanation |
MVS: The message indicates that NETSIR has started execution. The system maintenance and zap levels are displayed. |
System Action |
NETSIP continues execution. |
User Action |
None required. This message is informational only. |
NETS601 | NETW Entire Net-Work 5 INITIALIZATION PARAMETER NOT RECOGNIZED |
Explanation |
MVS: The parameter parsing process has encountered an invalid parameter name. |
System Action |
NETSIR terminates abnormally. |
User Action |
Correct the parameter value and rerun the job. |
NETS602 | NETW Entire Net-Work 5 INITIALIZATION PARAMETER(S) ERROR |
Explanation |
MVS: The parameter validation process has encountered an invalid parameter value. |
System Action |
NETSIR terminates abnormally. |
User Action |
Correct the parameter value and rerun the job. |
NETS603 | NETW ENTER Entire Net-Work COMMON AREA SUBPOOL (C =CSA OR S =SQA) ------- OR 'A' TO ABORT Entire Net-Work 5 INITIALIZATION |
Explanation |
MVS: The value specified for the CSTORAGE parameter is invalid. |
System Action |
NETSIR prompts the operator to enter a correct value. |
User Action |
Enter the correct value for the parameter or 'A' to terminate NETSIR processing. |
NETS604 | NETW LEAVE MESSAGE NETS650 OR NETS631 THRU NETS649 (N OR Y) |
Explanation |
MVS: The value specified for the LEAVE parameter is invalid. |
System Action |
NETSIR prompts the operator to enter a correct value. |
User Action |
Enter the correct value. |
NETS605 | NETW ENTER Entire Net-Work 5 INTERRUPT QUEUE SIZE NETW ENTER Entire Net-Work 5 INTERRUPT QUEUE SIZE (0-9999) OR 'A' TO ABORT Entire Net-Work 5 INITIALIZATION |
Explanation |
MVS: The value specified for the QSIZE parameter is invalid. |
System Action |
NETSIR prompts the operator to enter a correct value. |
User Action |
Enter the correct value for the parameter or 'A' to terminate NETSIR processing. |
NETS606 | NETW ENTER Entire Net-Work 5 SVC NUMBER (200-255) OR 'A' TO ABORT Entire Net-Work 5 INITIALIZATION TO ABORT Entire Net-Work 5 INITIALIZATION |
Explanation |
MVS: The value specified for the SVCNR parameter is invalid. |
System Action |
NETSIR prompts the operator to enter a correct value. |
User Action |
Enter the correct value for the parameter or 'A' to terminate NETSIR processing. |
NETS607 | NETW PROMPT OPERATOR TO UPDATE SVC TABLE ENTRY (N or P) |
Explanation |
MVS: The value specified for the SVCTAB parameter is invalid. |
System Action |
NETSIR prompts the operator to enter a correct value. |
User Action |
Enter the correct value. |
NETS607 | NETW Entire Net-Work 5 SVC svc TABLE ENTRY AT svctaddr INVALID: IS value1 value2 SHOULD BE value3 value4 |
Explanation |
MVS: The value 'P' was specified for the SVCTAB parameter and the entry for SVC 'svc' located at address 'svctaddr' contained the values 'value1' and 'value2 . The values 'value3' and 'value4' are required. |
System Action |
This message is followed by message NETS608. |
User Action |
None required. This message is informational only. |
NETS608 | NETW SHOULD SVC TABLE ENTRY BE CHANGED ( Y ) OR SHOULD Entire Net-Work 5 INITIALIZATION BE ABORTED (N )? |
Explanation |
MVS: The value 'P' was specified for the SVCTAB parameter and an invalid SVCTABLE entry was encountered. |
System Action |
NETSIR prompts the operator to enter a correct value. This message is preceded by message NETS607. |
User Action |
Enter the correct value. |
NETS609 | NETW SVC XXX TABLE ENTRY CHANGED WITHOUT PROMPTING OPERATOR |
Explanation |
MVS: The value 'N' was specified for the SVCTAB parameter and an invalid SVCTABLE entry was encountered. |
System Action |
NETSIR modifies the SVCTABLE and continues processing. |
User Action |
None required. This message is informational only. |
NETS610 | NETW NON ZERO RETURN CODE FROM IUCV QUERY |
Explanation |
MVS: The program NETSIR has detected a non zero condition from the IUCV query for max. connections. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS611 | NETW UNABLE TO ACQUIRE COMMON STORAGE VIA GETMAIN |
Explanation |
MVS: The program NETSIR was unable to acquire common storage in the page-fixed CSA or SQA for the necessary control blocks. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Specify the other page-fixed storage area or increase the size of the fixed CSA or SQA and IPL the MVS system. |
NETS612 | NETW IUCV ERROR DURING CONNECT FUNCTION |
Explanation |
MVS: NETSIR detected a non zero return code from the dummy IUCV connect to determine MSGLIMIT. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS613 | NETW UNABLE TO ACQUIRE INTQ STORAGE VIA GETMAIN |
Explanation |
MVS: The program NETSIR was unable to acquire storage in the page-fixed CSA or SQA for either the Entire Net-Work 5 interrupt queue or the path table. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Specify the other page-fixed storage area or increase the size of the fixed CSA or SQA and IPL the MVS. |
NETS614 | NETW ESTAE EXIT HAS BEEN ENTERED IN NETSIR |
Explanation |
MVS: The NETSIR abend handler has been entered while running this utility. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. If the SIRDUMP file is available a dump of the SDWA will be printed. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS615 | NETW NON ZERO RETURN CODE FROM SEVER |
Explanation |
MVS: NETSIR has detected a non zero return from the IUCV sever function. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS616 | NETW IUCV PRODUCT ENTRY NOT IN CPIT |
Explanation |
MVS: NETSIR has detected that the Cross Product Interface Table has been initialized but it could not find an IUCV product entry. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS617 | NETW DECLARE BUFFER ALREADY DONE |
Explanation |
MVS: NETSIR has detected that another program has previously done an IUCV declare buffer and NETSIR cannot find the necessary entries in the Cross Product Interface Table to obtain the address of the external buffer. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS618 | NETW NO FREE SLOTS IN CPIT |
Explanation |
MVS: The Cross Product Interface Table is full. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS619 | NETW CROSS PRODUCT SUBSYSTEM NOT DEFINED |
Explanation |
MVS: NETSIR has detected that the subsystem for the Cross Product Interface Table is not in the SSCVT chain. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Execute NETSIP to define the CPIT subsystem or define the CPIT subsystem before the NETW subsystem. |
NETS620 | NETW CPIT LENGTH NOT SET IN SSCVT |
Explanation |
MVS: NETSIR has detected that the Cross Product Interface Table has been initialized but the length was not available in the SSCVT entry. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS621 | NETW CPIT INCORRECTLY INITIALIZED |
Explanation |
MVS: NETSIR has detected that the Cross Product Interface Table has been defined but the SSCVT entry is invalid. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS622 | NETW OPERATING SYSTEM NOT MVS |
Explanation |
MVS: An attempt was made to execute the MVS version of NETSIR in an environment other than MVS. |
System Action |
NETSIR terminates abnormally. |
User Action |
Execute the version of NETSIR which matches your system or upgrade your system to a supported level of MVS. |
NETS623 | NETW NO DD STATEMENT FOR SIRDUMP FOUND |
Explanation |
MVS: The SNAP parameter was specified but no DD statement for the file SIRDUMP was found. |
System Action |
NETSIR terminates abnormally. |
User Action |
Supply a DD statement for SIRDUMP in the JCL. |
NETS624 | NETW NETSIR PRB CANNOT FOUND |
Explanation |
MVS: The residency mode for NETSIR could not be ascertained because no program request block for NETSIR could be located. |
System Action |
NETSIR terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS625 | NETW NETSIR RMODE NOT 24 |
Explanation |
MVS: In an MVS/XA or MVS/ESA environment NETSIR was link edited to run with residency mode ANY. |
System Action |
NETSIR terminates abnormally. |
User Action |
Check the residency mode of NETSIR and relink with RMODE 24. |
NETS626 | NETW NETSIR TERMINATED DUE TO OPERATOR REQUEST |
Explanation |
MVS: The operator requested NETSIR to abort when prompted to enter parameter input. |
System Action |
NETSIR terminates abnormally. |
User Action |
Check the reason for the operator input. |
NETS627 | NETW ACRONYM CHECK FAILURE FOR PROGRAM - NETSVC |
Explanation |
MVS: NETSIR encountered an incorrect version NETSVC. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Verify that the correct version of NETSVC is in load library. |
NETS628 | NETW SVCUPDTE MACRO FAILURE |
Explanation |
MVS: NETSIR could not modify the MVS SVCTABLE to suit the Entire Net-Work SVC. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Contact local Entire Net-Work support personnel. |
NETS629 | NETW MVS NOT RUNNING UNDER VM |
Explanation |
MVS: The MVS system NETSIR is not running under z/VM. |
System Action |
NETSIR terminates abnormally. |
User Action |
Chose another access method suited to physical environments such as VTAM or Channel-to-Channel. |
NETS630 | NETW EXTERNAL NEW PSW NOT REPLACED IN THE RESTART FLIH |
Explanation |
MVS: NETSIR could not install the IUCV support module in the MVS restart routine. |
System Action |
NETSIR continues processing. |
User Action |
Contact local Entire Net-Work support personnel. IUCV communication will be lost if a system restart is performed. |
NETS640 | NETW NO EXTERNAL INTERRUPT ROUTINE FOUND FOR REPLACE PARAMETER |
Explanation |
MVS: The REPLACE parameter was specified for the FLIH but the IUCV support module was not active. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Execute NETSIR without the REPLACE parameter. |
NETS641 | NETW EXTERNAL INTERRUPT ROUTINE SUCCESSFULLY REPLACED |
Explanation |
MVS: The REPLACE parameter was specified for the FLIH. The IUCV support module was replaced. |
System Action |
NETSIR continues processing. |
User Action |
None required. This message is informational only. |
NETS642 | NETW SNAP PROCESSING COMPLETED |
Explanation |
MVS: The SNAP parameter was specified. The Entire Net-Work data areas have been put out to the SIRDUMP file. |
System Action |
NETSIR continues processing. |
User Action |
None required. This message is informational only. |
NETS643 | NETW THE EXTERNAL INTERRUPT ROUTINE WAS LINKED WITH RMODE=ANY |
Explanation |
MVS: In an MVS/XA or MVS/ESA environment NETFLIH was link edited to run with residency mode ANY. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Check the residency mode of NETFLIH and relink with RMODE 24. |
NETS644 | NETW THE EXTERNAL INTERRUPT ROUTINE WAS LOADED INTO PROTECTED STORAGE |
Explanation |
MVS: In an MVS/XA or MVS/ESA environment the fixed LPA was page protected. |
System Action |
NETSIR backs out any modifications to the system and terminates abnormally. |
User Action |
Specify the NOPROT option in the fix list in IAESYSxx and IPL the MVS system. |
NETS650 | NETW Entire Net-Work COMMON AREA FOR VC XXX INITIALIZED |
Explanation |
MVS: The Entire Net-Work environment has been successfully initialized. |
System Action |
NETSIR terminates normally. |
User Action |
None required. This message is informational only. |