The VW command enables you to view the data accumulated by a history report or a report that has been started. The command may be issued from any of the list function screens (LR, LS, and LH).
When you issue the VW command, the display program associated with the report is executed, and the collected data is displayed online.
To view report results
Enter the command VW on the selection line preceding the name of a history report or a report that has been started.
An example of report results available using the VW command is shown in the Thread Activity screen below:
14:46:43 THREAD ACTIVITY 2003-07-07 01:49:04 07-27-1996 Thru 14:46:43 07-27-1996 LOCL=00009 Total Total Avg Avg Thd Commands IOs IOs Total-Dur --- ------------ ------------ ------------ -------------- 1 206054 72128 0 0.009776 2 7652 3467 0 0.023517 3 207 151 0 0.043532 4 8 1 0 0.015584 *** 213921 75747 0 0.010301 ***** E N D O F R E P O R T ***** Command: _____________________________________________________________________ Enter-PF1---PF2---PF3---PF4---PF5---PF6---PF7---PF8---PF9---PF10--PF11--PF12--- Help Sort Exit Menu |
Note:
Restrictions apply to the commands that may be issued while viewing
reports. For more information, refer to document
Command
Reference.
When reports have more columns than will fit on a screen, PF10 and PF11 may be used to scroll the display to the left or right. When available, these keys are marked with left and right arrows. PF10 scrolls the display to the left, and PF11 scrolls the display to the right. The first column is repeated on each screen.