Administration Version 5.9.1
 —  Entire Net-Work Administration  —

Estimating Storage Requirements

Given the complexity of today's data processing environments, it is almost impossible to provide methods to predict the exact storage requirements of a software product.

The following tables provides rough estimates about the fixed storage requirements of Entire Net-Work and its various components, ignoring operating system-related storage requirements, which typically vary from installation to installation.

Table 1 contains the amounts of storage obtained from the operating system based on parameter specification or appropriate defaults. It does not include storage areas that are directly related to the operating system, such as operating system control blocks, I/O-related buffers, and control blocks (except where they are part of Entire Net-Work program modules or data areas).

Table 2 contains the amounts of storage obtained from the Entire Net-Work buffer pools by the control module and the various line drivers.

Table 3 contains special storage requirements of the line drivers (such as special common system storage areas) in the various operating system environments.


Table 1: Storage Areas Obtained from System

  z/OS
Request queue:
(NC parameter+1)*192
AS(X)
Attached buffers:
(NAB parameter*4112)
AS(X)
Entire Net-Work buffer pools: (specified size + ca. 1% for administration, rounded up to nearest 2KB or 4KB)
Asynchronous buffers Long-term buffers Short-term buffers Page-fixed buffers AS(X) AS AS(X) AS
Entire Net-Work trace table AS(X)
Entire Net-Work control blocks: AS
Node Target Path 48 32 32

Driver TCPX

4KB 4KB 4KB
544
2048

Link TCPX

256 168 1KB
992
640
ADAIOR data areas: AS
(for trace table, ECB list, etc.) ca 2KB
Abbreviation Meaning
AS from address space (private, below 16MB if XA or XS)
AS(X) from address space (private, above 16MB if XA or XS)
SYS from system GETVIS area (VSE in VAE mode)
Part from partition (VSE not in VAE mode)
Virt.M from virtual machine
Comm.Pool from common memory pool

Top of page

Table 2: Storage Obtained from Entire Net-Work Buffer Pools

Buffer pools: Asynch Long-term Short-term Page-fixed
Segment size: 64 64 512 2KB or 4KB
Usage by:        
Control module   UB MSG RPLY  
Queue managers     BLK BLK

Explanations

BLK Storage for outgoing transmission blocks (after compression and blocking), from short-term pool or page-fixed pool, depending on line driver requirements. Storage requirements for one transmission block include, in addition to the messages contained, 48 bytes for a transmission block header.
MSG All messages sent or received; output messages kept until acknowledged by the access method, input messages kept until processed.
  The size of a message can be computed in the following way:
56 bytes for a message header
+ maxpath * 2 bytes for a node stack
+ 128 bytes for UB, ACB, etc.
+ size of FB, RB, SB, VB, IB to send or receive
RECV Storage for incoming message data until transferred to short-term buffers (in paging systems only).
RPLY A reply buffer for each user request for a target on this node if the information returned by the target will not fit into the original message buffer (that is, if a large record buffer or ISN buffer is to be returned to the user).
SMBLK 1 segment for each message that cannot be sent in one transmission, kept until the message is acknowledged by the adjacent node.
UB (only if 31-bit mode:) 64 bytes per user request for a target on this node, for the duration of the Adabas call.
WTO Operator messages; kept until the message is written.
2WAY Storage for reply messages in the length of messages sent when the SEND 2WAY protocol is used (page-fixed in paging systems only).

Top of page

Table 3: Special Storage Requirements of Line Drivers

Driver Special Storage Requirements

TCPX

NUMUSERS*256 is initially allocated from buffer pool storage for the Active Client Table (ACT). This value may dynamically expand if required.

Note:
In addition to the storage estimates shown in the table, approximately 250KB storage is required for executable code.

Top of page