Version 7.4.4
 —  Utilities  —

INT: Interpreted Print Format

graphics/util_adaick_int.png

This function requests that blocks are printed in an interpreted format. See the NOINT function for information about suppressing interpreted print format. This function should only be used in conjunction with the ASSOPRINT, DATAPRINT, FCBPRINT, FDTPRINT, GCBPRINT, and PPTPRINT functions.

If both the INT and DUMP functions are specified, blocks are printed in both formats.


Optional Parameter

NOUSERABEND: Termination without Abend

When an error is encountered while the function is running, the utility prints an error message and terminates with user abend 34 (with a dump) or user abend 35 (without a dump).

If NOUSERABEND is specified, the utility will not abend after printing the error message. Instead, the message "utility TERMINATED DUE TO ERROR CONDITION" is displayed and the utility terminates with condition code 20.

Top of page