Version 7.4.4
 —  Messages and Codes  —

PL6nnna and PL6ann-PRILOG6 Print Program Messages

The following message groups are described:


Top of page

Messages from the Independent Components

Overview of Messages

PL6000I | PL6001E | PL6002E
PL6000I CARD READ =>control-card
Explanation:

Displays the PRILOG6 input control card that was read.


PL6001E UNRECOGNIZED INPUT CARD
Explanation:

One of the control cards read was not recognized by PRILOG6.

Action:

Ensure that all cards either being with PRILOG6 or an asterisk (*) for a comment line.


PL6002E INVALID PARM: parameter
Explanation:

The specified input parameter or value in the PRILOG6 control cards is invalid.

Action:

Correct the identified parameter and rerun the program.


Top of page

Messages from the System-Dependent Component

Overview of Messages

PL6D01 | PL6D02
PL6D01 DDCARD FILE FAILED TO OPEN, USING DEFAULTS
Explanation:

The input card file could not be opened.

Action:

If the defaults are used, there are no input cards and this file is not required. The message can be ignored. The default values are CLOGLAYOUT=5 and FIELDS=(LIST).

If values other than the defaults are required, ensure that the file is available and rerun the job.


PL6D02 DDCLOGIN FILE FAILED TO OPEN - NO REPORTS
Explanation:

The file containing the CLOG records did not open. No reports are printed.

Action:

Ensure that the file is properly allocated and rerun the job.