Version 7.4.4
 —  Messages and Codes  —

ADASIPnn (Adabas VSE/ESA SVC) System Messages

Overview of Messages

ADASIP00 | ADASIP01 | ADASIP02 | ADASIP03 | ADASIP04 | ADASIP05 | ADASIP06 | ADASIP07 | ADASIP08 | ADASIP09 | ADASIP10 | ADASIP11 | ADASIP12 | ADASIP13 | ADASIP14 | ADASIP15 | ADASIP17 | ADASIP18 | ADASIP19 | ADASIP20 | ADASIP21 | ADASIP22 | ADASIP23 | ADASIP24 | ADASIP27 | ADASIP28 | ADASIP29 | ADASIP30 | ADASIP31 | ADASIP32 | ADASIP33 | ADASIP34 | ADASIP36 | ADASIP40 | ADASIP41 | ADASIP50 | ADASIP60 | ADASIP61 | ADASIP62 | ADASIP63 | ADASIP64 | ADASIP65 | ADASIP66 | ADASIP67 | ADASIP68 | ADASIP69 | ADASIP70 | ADASIP71 | ADASIP72 | ADASIP73 | ADASIP74 | ADASIP75 | ADASIP76 | ADASIP77 | ADASIP78

ADASIP00 ADABAS Vv VSE SIP STARTED SIP IS RUNNING UNDER VSE sys-type - mode
ADASIP00 ( yy yy - mm - dd. SM=sm-level , ZAP=zap-level)
ADASIP00 SIP IS RUNNING UNDER OSYS LEVEL Vnnn
ADASIP00 SIP IS LOADING ADABAS SVC LEVEL Vnnn
ADASIP00 ADASIP IS LOADING ADABAS SVC AMODE=a-mode
Explanation:

The ADASIP program has started. "sys-type" is the operating system type, and "mode" is the ECPS (EMODE), VM, or 370 operating mode.

v version of Adabas
sys-type VSE operating system type
mode ECPS (EMODE), VM, or S/370 operating mode
yyyy-mm-dd date of module assembly
sm-level system maintenance (SM) level of the module
zap-level ZAP level of the module
Vnnn version/release/modification level resulting from an IBM SUBSYD macro
a-mode the AMODE setting of the Adabas SVC

ADASIP01 SUBSID MACRO ERROR
Explanation:

ADASIP received a nonzero return code from the operating system.

User Action:

The VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation documentation for the minimum allowed VSE levels.


ADASIP02 UNSUPPORTED VSE RELEASE BASED UPON SUBSID
Explanation:

An ADASIP validation check indicates an unsupported operating system level.

User Action:

The VSE operating system release level is too low for installing Adabas. Refer to the Adabas Installation documentation for the minimum allowed VSE levels.


ADASIP03 NO SYSPARM VALUE SPECIFIED FOR SVC
Explanation:

ADASIP could not find a SYSPARM input, and a ZAP has not be applied to the specified SVC.

User Action:

Either provide the SVC with SYSPARM or apply a ZAP to the specified SVC with ADASIP.


ADASIP04 DEFAULT VALUE USED FOR THE SVC
Explanation:

No SYSPARM SVC has been used. ADASIP defaults to using the SVC that has a ZAP applied.


ADASIP05 NON-NUMERIC DATA FOUND IN SYSPARM FIELD
Explanation:

Either SYSPARM or the default ADASIP SVC contains a nonnumeric value.

User Action:

Correct the specified SYSPARM value, or set the default SVC value to 30.


ADASIP06 INVALID RANGE SPECIFIED FOR THE SVC 31-120
Explanation:

ADASIP found an SVC outside the allowed range in SYSPARM or the ADASIP default SVC.

User Action:

Set the SVC to an unused SVC value within the allowed range. SVC ranges and recommended values are described in the Adabas Installation documentation .


ADASIP07 SVC SPECIFIED NOT WITH VALID RANGE - NO UPSI
Explanation:

The value specified for the SVC in the VSE SYSPARM with the UPSI option was incorrect.

User Action:

Correct the UPSI or SVC value, as appropriate. SVC ranges and recommended values are described in the Adabas Installation documentation .


ADASIP08 ADASVCvv WAS NOT FOUND IN THE SVA
Explanation:

While performing a VSE load, ADASIP found that the specified level ADASVC was not in the SVA.

User Action:

Issue the SET SDL for ADASVCvv. It may be necessary to relink the Adabas SVC with SVA using the PHASE statement if the Adabas SVC is not found in the Adabas library.


ADASIP09 NO MATCH ON ID - INCORRECT ADASVC LOADED
Explanation:

ADASIP found an incorrect SVC version while attempting a load operation.

User Action:

Relink ADASVCvv with the correct SVC module.


ADASIP10 NO KEYWORD SPECIFIED FOR NRIDTES
Explanation:

ADASIP found an incorrect NRIDTES keyword.

User Action:

Respecify the keyword parameter as NRIDTES=nn , where "nn" specifies the number of databases to be supported in the ID table.


ADASIP11 NON-NUMERIC DATA SPECIFIED FOR NRIDTES
Explanation:

The ADASIP NRIDTES= keyword parameter specified non-numeric data.

User Action:

Correct the NRIDTES= data, then resubmit ADASIP.


ADASIP12 NO OVERRIDING NRIDTES SPECIFIED
Explanation:

The default NRIDTES was used. No error has occurred.


ADASIP13 SVC TABLE ENTRY WAS FOUND TO BE INVALID
Explanation:

The SVC number provided by SYSPARM is either not valid, or does not represent either the old or new version of the VSE Adabas SVC. This error can occur if the UPSI statement's "C" parameter specified "0".

User Action:

Respecify the UPSI statement, or specify another unused SVC value. Rerun ADASIP.


ADASIP14 GETVIS FAILURE FOR IDT IN SVA
Explanation:

The GETVIS of the IDT passed a nonzero return code back to ADASIP, meaning the GETVIS size was insufficient.

User Action:

Increase the SVA GETVIS size, re-IPL the operating system, and rerun ADASIP.


ADASIP15 ROUTER UNABLE TO INITIALIZE IDT
Explanation:

ADASIP received a nonzero return code from the 56 call to the SVC.

User Action:

Contact your Software AG technical support representative.


ADASIP17 INCORRECT SVC SUFFIX AFTER COMMA IN SYSPARM
Explanation:

An attempt was made to run this program more than once for the current IPL. A second IDT for the program is not required.

User Action:

Correct the SYSPARM specification for the two-byte SVC suffix, and rerun the job.


ADASIP18 NON-NUMERIC DATA SPECIFIED FOR DMPDBID
Explanation:

The ADASIP DMPDBID keyword parameter contains nonnumeric data.

User Action:

Correct the DMPDBID specification, and rerun the job.


ADASIP19 DBID CANNOT BE FOUND IN IDTE
Explanation:

The ADASIP program could not find an entry for the DMPDBID database in the IDT area.

User Action:

Either correct the DMPDBID specification or start the specified database, then run ADASIP to perform a "snap" dump of the command queue.


ADASIP20 THE IDT AND SVC HAVE BEEN DUMPED TO SYSLST
Explanation:

A request to ADASIP to dump the IDT and then SVC via UPSI 80. No error has occurred.


ADASIP21 NO IDT TABLE WAS FOUND FOR SPECIFIED SVC
Explanation:

ADASIP found that the SVC has no address for the IDT.

User Action:

Specify the correct SVC, or initialize with ADASIP first.


ADASIP22 THE SVC HAS ALREADY BEEN INSTALLED
Explanation:

ADASIP found that the same program is being run again.

User Action:

The SVC is not installed and no IDT table is needed. To reinstall the same SVC, you must first perform a SET SDL.


ADASIP23 THE SVC TABLE CANNOT BE LISTED UNDER DOS/MVT
Explanation:

The option to display the SVC table is specified under VSE.


ADASIP24 THE IDT HAS BEEN PAGEFIXED BY USER OPTION
Explanation:

UPSI (X'20') was selected to pagefix the IDT in the system GETVIS area.


ADASIP27 ADASVC IS RMODE=ANY
Explanation:

ADASIP detected that the Adabas SVC is linked RMODE=ANY.

User Action:

Relink the Adabas SVC RMODE=24.


ADASIP28 ADASIP IS AMODE=31
Explanation:

ADASIP detected that it is AMODE=31.

User Action:

Relink ADASIP AMODE=24.


ADASIP29 PRODID MACRO FAILURE
Explanation:

ADASIP received a nonzero response code from the PRODID DEFINE macro.

User Action:

Investigate the cause of the error. Correct it and rerun the job.


ADASIP30 ADASVCvv svc INSTALLED
Explanation:

ADASIP has installed SVC number "svc" successfully.


ADASIP31 address=SVC ADDRESS
Explanation:

The SVC has been loaded at the indicated address.


ADASIP32 address=IDT ADDRESS
Explanation:

The ID table has been allocated at the indicated address.


ADASIP33 address=ALET TABLE ADDRESS
Explanation:

The ALET table has been loaded at the indicated address.


ADASIP34 count=MAXIMUM USER/TARGET COMBINATIONS
Explanation:

Total number of client/server combinations within the VSE system.


ADASIP36 address=EXTENDED IIBS ADDRESS
Explanation:

The extended IIBs have been loaded at the indicated address.


ADASIP40 VSE SVC svc IS status AM=a-mode RM=r-mode AR=reg-mode SVCT=svc-tab-addr MODT=svc-mod-addr
Explanation:

This message occurs when the option to list the SVC table is selected, and specifies the following values:

svc the VSE SVC number
status "USED" or "UNUSED"
a-mode AMODE of this SVC, if used (24 or ANY)
r-mode RMODE of this SVC, if used (24 or ANY)
reg-mode access register mode of this SVC, if used
(Y=yes, N=no)
svc-tab-addr address of the SVC table entry for this SVC
svc-mod-addr address of the SVC mode table entry for this SVC, if present
User Action:

None required. This message is for your information only. Do not use SVC50, even though it is indicated as "unused".


ADASIP41 VSE SVC TABLE AUDIT COMPLETED
Explanation:

ADASIP has completed listing the VSE SVC table.


ADASIP50 THE COMMAND QUEUE HAS BEEN DUMPED TO SYSLST
Explanation:

ADASIP has completed listing the command queue for the specified database.


ADASIP60 ONLY 1 CPU CAN BE ACTIVE DURING ADASIP
Action:

Use "SYSDEF TD,STOP=ALL" to stop all but one CPU so that ADASIP can run. Then restart your CPUs again.


ADASIP61 RERUN ADASIP AFTER USING TDSERV TO STOP CPUS
Explanation:

Occurs in conjunction with ADASIP60.


ADASIP62 GETVIS FAILED FOR ADASTUB MODULE
Explanation:

Not enough SVA storage to load ADASTUB.

Action:

Consult with your system programmer.


ADASIP63 ADASTUB MODULE LOADED AT address
Explanation:

Information message indicating module load address.


ADASIP64 NO MATCH ON ID - INCORRECT ADASTUB LOADED
Explanation:

ADASTUB phase is incorrect.

Action:

Consult with your system programmer, or contact Software AG.


ADASIP65 ADASTUB SVC TABLE NOT FOUND
Explanation:

ADASTUB phase is incorrect.

Action:

Consult with your system programmer, or contact Software AG.


ADASIP66 ADASTUB SVC TABLE IS FULL
Explanation:

You have more than 10 SVCs active on this VSE machine.

Action:

Contact Software AG for information about increasing the table size.


ADASIP67 PAGEFIX FOR ADASIP FAILED
Action:

Increase the SETPFIX value and rerun.


ADASIP68 PAGEFREE FOR ADASIP FAILED
Action:

Consult with your system programmer.


ADASIP69 TURBO DISPATCHER STUB A C T I V E
Explanation:

Adabas Turbo support is now active on this VSE machine.


ADASIP70 VSE SUPERVISOR HOOK INSTALL FAILED
Explanation:

Either this version of the VSE/ESA 2 supervisor is not supported, or the vendor installation logic for the first-level interrupt handler is incorrect.

Action:

Call Software AG; have message ADASIP72 available.


ADASIP71 LOAD OF MODULE ADASTUB FAILED
Explanation:

The ADASTUB module was not found in the LIBDEF SEARCH chain.


ADASIP72 CODE IS : xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Explanation:

Occurs after message ADASIP70.


ADASIP73 ADANCHOR INCORRECT OR NOT FOUND IN SVA
Explanation:

The ADANCHOR module was not found in the SVA; no SET SDL has been done.


ADASIP74 INFO : STUB ACTIVATED BY PREVIOUS ADASIP
Explanation:

Adabas Turbo STUB has been installed by a previous ADASIP.


ADASIP75 ADANCHOR AND ADASTUB NOT DUMPED - NOT ACTIVE
Explanation:

When attempting to dump Adabas control blocks with ADASIP, the modules were not dumped because Adabas Turbo support is not active.


ADASIP76 ADABAS TURBO STUB NOT ACTIVATED DUE TO ERROR
Explanation:

An error occurred during the installation of the Adabas Turbo stub.


ADASIP77 THIS ADABAS SVC WILL RUN IN NON-TURBO MODE
Explanation:

An error occurred during the installation of the Adabas Turbo stub. This SVC will run in non-Turbo mode from now on.


ADASIP78 VSE TURBO DISPATCHER VERSION nn
Explanation:

Version of VSE/ESA version 2 Turbo Dispatcher. 00 indicates TD level of pre-version 4.


Top of page