Note:
Each of the messages in this section starts with the relevant database
ID.
ADAL01 | ADAL02 | ADAL03 | ADAL04 | ADAL05 | ADAL06 | ADAL07 | ADAL10 | ADAL11 | ADAL12
ADAL01 | CLOG NOT ACTIVE |
Explanation: |
The command log is sequential, and the DDLOG dataset was either set to "dummy" or could not be opened. Command logging is switched off. |
ADAL02 | CLOGRn IS ACTIVE |
Explanation: |
The specified command log for dual or multiple command logging is now active. |
ADAL03 | COMMAND LOG DDCLOGRn HAS STARTED |
Explanation: |
Command logging has switched to dataset DD/CLOGRn . |
ADAL04 | WARNING : NOW IT IS TOO LATE TO COPY DDCLOGRn |
Explanation: |
The specified dual or multiple command logging dataset is being overwritten with new log data, and is no longer valid . |
ADAL05 | I/O ERROR ON DDCLOGRn. COMMAND LOGGING TERMINATED |
Explanation: |
Command logging to dataset DDCLOGRn was terminated by an I/O error . |
ADAL06 | COMMAND LOG IS NOT AVAILABLE |
Explanation: |
None of the dual or multiple command logging datasets was available (presently being copied by ADARES) . Command logging is switched off. |
ADAL07 | COMMAND LOG COULD NOT BE OPENED |
Explanation: |
An invalid command logging device or size was specified, or an I/O error on either the first or last block was detected. Command logging is switched off. |
ADAL10 | PPT ERROR nn PROCESSING CLOG |
Explanation: |
An error occurred while processing the parallel participant table (PPT). The nucleus stays up, but command logging is disabled. |
Action: |
Collect diagnostic information such as that provided by the ADAICKPPTPRINT function. Provide the error number "nn" and the PPTPRINT to your Software AG technical support representative. It may be necessary to format the PPT and restart the nuclei in order to rebuild the PPT. |
ADAL11 | WARNING - CLOG DATASETS HAVE CHANGED. PPT OVERWRITTEN. |
ADAL11 | USE ADARES MERGE CLOG TO COPY PREVIOUS CLOG DATASETS. |
Explanation: |
Either the CLOG datasets are different from what was specified in the last session or no CLOGs are specified but the previous CLOGs were not copied. The PPT information about these datasets is being overwritten. |
Action: |
If the contents of the CLOGs are still needed, they must be copied with the CLCOPY function and then merged manually. If the contents are not needed, no action is required. |
ADAL12 | date time CLOGMRG=YES NOT VALID. CLOGMRG NOT IN EFFECT. |
Explanation: |
This message is generated if an attempt is made to initialize a non-plex/ASM nucleus (NUCID=0) with CLOGMRG=YES specified. This is an informational message only and the nucleus will come up. CLOGMRG=YES should only be specified if NUCID is greater than 0. |
Action: |