ADATST (Issuing Adabas Commands)

This document describes the utility "ADATST".

The following topics are covered:


Functional Overview

The ADATST utility is used to fill the control block and the necessary buffers in order to issue Adabas commands.

Both the old ACB Adabas command interface and the new ACBX command interface are supported. For more information on the command interfaces please refer to the Command Reference documentation. Note that the ACB interface can be considered as a subset of the ACBX interface: Fields in the old ACB Adabas control block are also contained in the new ACBX control block (or the ABDs – the Adabas buffer descriptions) with the difference that some ACB fields are smaller then the corresponding fields in the new interface. In particular the buffer lengths have been increased that now Adabas buffers greater than 64 KB are possible. Switching between the interfaces is possible, but when you switch back to the old ACB interface you must be aware of the restrictions of the old ACB interface.

This utility is a multi-function utility.

Procedure Flow

graphics/adatst.png

Data Set Environment
Variable/
Logical Name
Storage
Medium
Additional Information
Control statements stdin/
SYS$INPUT
  Utilities Manual
ADATST messages stdout/
SYS$OUTPUT
  Messages and Codes

Checkpoints

The utility writes no checkpoints.

Control Parameters

Note:
In the following, "string" is an ASCII string or 0x followed by hexadecimal data.

The following control parameters are available:

      A1 {=|:} string

      A2 {=|:} string

      A3 {=|:} string

      A4 {=|:} string

      A5 {=|:} string

      A6 {=|:} string

      ABD

      ALOOP [= number]

      CB

      CBDUMP

      CC = string

      CID = string

      CO1 = string

      CO2 = string

      CO3 = string

      CO4 = string

      CO5 = string

      CO6 = string

      CO7 = string

      CO8 = string

M     DBID = number

      DLOOP

      ELOOP

      ERRORS = number

      EXECUTE = { number |  ISNQ }

      FB [{=|:} string]

      FB2  [{=|:} string]

      FB3  [{=|:} string]

      FBL = number 

      FB2L [= number] 

      FB3L [= number]

      FILE = number

      GO  [= { number | ISNQ } ]

      IB [= (number [,number]...)]

      IBL = number

D     INTERFACE = keyword

      ISN = number

      ISND = number

      ISNI = number

      ISNL = { number |  ISN }

      ISNQ = number

      LOOP

      MB = (number_buffers, number_isns)

D     [NO]OUTPUT

      OVERWRITE_RB = string

      OVERWRITE_RB2 = string

      OVERWRITE_RB3 = string

      RB [{=|:} string]

      RB2 [{=|:} string]

      RB3 [{=|:} string]

      RBL = number

      RB2L [= number]

      RB3L [= number]

      READ_RB = string

      READ_RB2 = string

      READ_RB3 = string

      RESPONSE = number

      SB [{=|:} string]

      SBL = number

      TIME

D   [NO]TRACE

      VB [{=|:} string]

      VBL = number

D   WAIT [= [time]]

      WRITE_RB = string

      WRITE_RB2 = string

      WRITE_RB3 = string

A1

A1 {=|:} string

This parameter sets the Additions 1 field.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

A2

A2 {=|:} string

This parameter sets the Additions 2 field.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

A3

A3 {=|:} string

This parameter sets the Additions 3 field.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

A4

A4 {=|:} string

This parameter sets the Additions 4 field.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

A5

A5 {=|:} string

This parameter sets the Additions 5 field.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

A6

A6 {=|:} string

This parameter sets the Additions 6 field.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

ABD

ABD

This parameter is available only after specifying INTERFACE=ACBX. It displays the Adabas buffer definitions for the Adabas buffers that are currently defined.

ALOOP

ALOOP [= number]

This parameter opens a loop to add more lines. `number' is a line number. If a line number is specified, new lines are added from that point, overwriting existing lines; if no number is specified, new lines are added at the end. Close the loop with ELOOP.

CB

CB

This function displays the contents of the control block.

If the parameter INTERFACE=ACB is specified, only the fields contained in the old ACB Adabas control block are displayed.

If the parameter INTERFACE=ACBX is specified, the fields contained in the new ACBX Adabas control block but not in the old ACB Adabas control block are also displayed.

CBDUMP

CBDUMP

This function dumps the control block in hex.

CC

CC = string

This parameter specifies the command code.

CID

CID= string

This parameter specifies the command ID.

CO1

CO1 = string

This parameter sets the command option 1.

CO2

CO2 = string

This parameter sets the command option 2.

CO3

CO3 = string

This parameter sets the command option 3.

CO4

CO4 = string

This parameter sets the command option 4.

CO5

CO5 = string

This parameter sets the command option 5.

CO6

CO6 = string

This parameter sets the command option 6.

CO7

CO7 = string

This parameter sets the command option 7.

CO8

CO8 = string

This parameter sets the command option 8.

DBID

DBID = number

This parameter specifies the database to be used.

DLOOP

DLOOP

This function displays a saved command loop.

ELOOP

ELOOP

This function terminates a loop.

ERRORS

ERRORS = number

This parameter specifies the number of errors permitted before termination occurs.

EXECUTE

EXECUTE = { number |  ISNQ }

This parameter executes a loop `n' times, where `n' is specified by `number' or by ISNQ. Enter CTRL/C to terminate a loop.

FB

FB [{=|:} string]

This parameter is used to display the first format buffer or enter data into the format buffer. The length is set implicitly.

FB2

FB2 [{=|:} string]

This parameter is used to display the second format buffer or enter data into the format buffer. The length is set implicitly.

FB3

FB3 [{=|:} string]

This parameter is used to display the third format buffer or enter data into the format buffer. The length is set implicitly.

FBL

FBL = number

This parameter defines the first format buffer length in the control block.

FB2L

FB2L = number

This parameter defines the second format buffer length in the control block.

FB3L

FBL3 = number

This parameter defines the third format buffer length in the control block.

FILE

FILE = number

This parameter specifies the file number.

GO

GO [= { number |  ISNQ } ]

This function calls Adabas once or `n' times, where `n' is specified by `number' or ISNQ. Enter CTRL/C to terminate a loop.

IB

IB [= (number [,number]...)]

This parameter is used to display the ISN buffer or enter ISNs. The length is set implicitly.

IBL

IBL = number

This parameter specifies the ISN buffer length in the control block.

INTERFACE

INTERFACE = keyword

This parameter is used to switch between the old and new Adabas command interface. Valid keywords are ACB and ACBX. The default is ACB. After INTERFACE = ACB has been specified, Adabas calls are performed with the old ACB Adabas interface - any fields that are only contained in the new ACBX Adabas control block and additional format buffers and record buffers are ignored. You can switch between the old and the new Adabas interface in one Adabas session.

ISN

ISN = number

This parameter sets ISN with the number supplied.

ISND

ISND = number

This parameter subtracts `number' from ISN.

ISNI

ISNI = number

This parameter adds `number' to ISN.

ISNL

ISNL = { number |  ISN }

This parameter is used to set the ISN lower limit with the number supplied, or to move the ISN from the control block into the ISN lower limit.

ISNQ

ISNQ = number

This parameter specifies the ISN quantity with the number supplied.

LOOP

LOOP

This function defines the start of a loop. All commands that follow will be saved until an ELOOP is entered.

MB

MB = (number_buffers, number_isns)

This parameter defines the number of multifetch buffers and the number of IS entries that can be stored in a multifetch buffer. number_buffers may be a number between 0 and 3. number_isns must be a number >0.

The MB parameter can only be specified after INTERFACE = ACBX has been specified.. Since multifetch buffers are pure output buffers, it is not possible to enter content into the multifetch buffers.

Once multifetch buffers have been specified, you can display their contents with the RB, RB 2 and RB3 parameters.

[NO]OUTPUT

[NO]OUTPUT

If this option is set to NOOUTPUT, no messages are output when calling Adabas `n' times. Only error messages will be printed.

The default is OUTPUT.

OVERWRITE_RB

OVERWRITE_RB = string

This parameter specifies the name of an existing file to which the contents of the first record buffer are written. The current contents of the file will be overwritten.

OVERWRITE_RB2

OVERWRITE_RB2 = string

This parameter specifies the name of an existing file to which the contents of the second record buffer are written. The current contents of the file will be overwritten.

OVERWRITE_RB3

OVERWRITE_RB3 = string

This parameter specifies the name of an existing file to which the contents of the third record buffer are written. The current contents of the file will be overwritten.

RB

RB [{=|:} string]

This parameter is used to display the first record buffer or enter data into the first record buffer. For input to a file, the length is set implicitly.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

If you display the first record buffer, and at least one multifetch buffer has been defined with the MB parameter, the first multifetch buffer is also displayed.

RB2

RB2 [{=|:} string]

This parameter is used to display the second record buffer or enter data into the second record buffer. For input to a file, the length is set implicitly.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

If you display the second record buffer, and at least two multifetch buffers have been defined with the MB parameter, the second multifetch buffer is also displayed.

RB3

RB3 [{=|:} string]

This parameter is used to display the third record buffer or enter data into the third record buffer. For input to a file, the length is set implicitly.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

If you display the third record buffer, and at three multifetch buffer have been defined with the MB parameter, the third multifetch buffer is also displayed.

RBL

RBL = number

This parameter specifies the first record buffer length in the control block.

RB2L

RB2L = number

This parameter specifies the second record buffer length in the control block.

RB3L

RB3L = number

This parameter specifies the third record buffer length in the control block.

READ_RB

READ_RB = string

This parameter specifies the name of a file that is read into the first record buffer.

READ_RB2

READ_RB2 = string

This parameter specifies the name of a file that is read into the second record buffer.

READ_RB3

READ_RB3 = string

This parameter specifies the name of a file that is read into the third record buffer.

RESPONSE

RESPONSE = number

This parameter displays the error text for the given nucleus response code.

SB

SB [{=|:} string]

This parameter is used to display the search buffer or enter data into the search buffer. The length is set implicitly.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

SBL

SBL = number

This parameter specifies the search buffer length in the control block.

TIME

TIME

This function marks the current time, and displays the difference between this and the last time mark.

[NO]TRACE

[NO]TRACE

This option traces execute loops.

The default is NOTRACE.

VB

VB [{=|:} string]

This parameter is used to display the value buffer or enter data into the value buffer. The length is set implicitly. If `string' equals RB, the record buffer is moved into the value buffer.

If you specify an equals sign, the value given for 'string' will be converted to upper case; if you specify a colon, no upper-case conversion is performed.

VBL

VBL = number

This parameter specifies the value buffer length in the control block.

WAIT

WAIT [= seconds]

This parameter causes ADATST to wait for a given period. The waiting time is entered in seconds. Once the time is set, you can wait for the same period by entering 'WAIT' without any additions.

The default time is 10 seconds.

Example

adatst: wait = 15

ADATST waits for fifteen seconds.

WRITE_RB

WRITE_RB = string

This parameter specifies the name of a file to which the contents of the first record buffer are written. The record buffer is only written if a file with the specified name does not already exist.

WRITE_RB2

WRITE_RB2 = string

This parameter specifies the name of a file to which the contents of the second record buffer are written. The record buffer is only written if a file with the specified name does not already exist.

WRITE_RB3

WRITE_RB3 = string

This parameter specifies the name of a file to which the contents of the third record buffer are written. The record buffer is only written if a file with the specified name does not already exist.