Version 8.0
 —  Messages and Codes  —

Error Class 0800 - webMethods EntireX Adapter

Error messages are logged with error class 0800. In the Administrator, section Settings > Logging you find the logging settings in the tree for Adapters. See the webMethods Integration Server Administrator's Guide for changing the logging settings.


08000212 WmEntireX: exception during register: <exception detail>
Explanation

An error occurred during REGISTER call. This can happen when an adapter listener starts.

Action

Use exception detail to fix. This is typically a configuration issue.


08000213 WmEntireX: exception during receive: <exception detail>
Explanation

An error occurred during RECEIVE call in an adapter listener.

Action

Use exception detail to fix.


08000219 WmEntireX: connection.receive: unknown server command <actual command>
Explanation

<actual command> was send to the adapter listener. This is unknown and cannot be handled.

Action

Change command. The only known command is PING.


08000220 WmEntireX: connection.receive: conversational call <actual packet type> rejected
Explanation

The adapter listener does not support conversational RPC.

Action

Use non-conversational calls.


08000221 WmEntireX: connection.receive: illegal packet type <actual packet type>
Explanation

The adapter listener received an illegal packet type.

Action

Change your RPC client to send valid packet types.


08000229 WmEntireX: unsupported RPC protocol version: <actual protocol version>
Explanation

The RPC client is sending an old protocol version that is not supported by the adapter listener.

Action

Update your RPC client.


08000300 WmEntireX: exception during processing notification result: <exception details>
Explanation

The adapter listener trapped into an exception while processing the result of the notification execution.

Action

Use exception details to fix.


08000310 WmEntireX: listener.processNotificationResults error: <error details>
Explanation

The Integration Server runtime reported an error during notification.

Action

Use error details to fix.


08000333 WmEntireX: exception during syncListener.runNotification: <exception details>
Explanation

The adapter listener trapped into an exception while processing a notification event.

Action

Use exception details to fix.


08000401 WmEntireX: no program info for <program name> found in metadata info
Explanation

The metadata for this connection does not contain necessary info for this program.

Action

Re-create this connection.


08000402 WmEntireX: illegal program info for <program name> found in metadata info, length=<number of info blocks for the program>
Explanation

The metadata for this connection does not contain consistent info for this program.

Action

Re-create this connection.


08000403 WmEntireX: illegal program info for <program name> found in metadata info, length(headerInfos)=<number of info blocks for the program header>
Explanation

The metadata for this connection does not contain consistent info for this program.

Action

Re-create this connection.


08000404 WmEntireX: exception while processing metadata info: <exception details>
Explanation

The metadata for this connection does not contain consistent info for this program.

Action

Re-create this connection.


08000420 WmEntireX: exception while reading metadata info: <exception details>
Explanation

The metadata for this connection is not readable.

Action

Re-create this connection. Use exception details to fix.


08000421 WmEntireX: metadata info cannot be empty
Explanation

The metadata for this connection is empty.

Action

Re-create this connection.


08000422 WmEntireX: no library name found in metadata info
Explanation

The metadata for this connection does not contain an IDL library name.

Action

Re-create this connection.


08000423 WmEntireX: no programs found in metadata info
Explanation

The metadata for this connection does not contain an IDL program name.

Action

Re-create this connection.


08000424 WmEntireX: no information found for program <program name>
Explanation

The metadata for this connection does not contain the signature information for <program name>.

Action

Re-create this connection.


08000441 Illegal value of type <actual type>, <expected type> expected
Explanation

The actual parameter type provided by the Integration Server differs from the expected parameter type. The types are incompatible.

Action

Supply parameters of expected type.


08000442 Illegal value \"<actual value>\" for type <actual IDL data type>
Explanation

The actual parameter value provided by the Integration Server does not match the expected parameter type.

Action

Use exception details to fix this.


08000443 Illegal type <actual type> for <parameter name>
Explanation

The parameter has an unknown IDL type.

Action

Contact Software AG support.


Top of page